Cargando…

Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study

BACKGROUND: Maintaining optimal intracuff pressure of the endotracheal tube is important during airway management. Rotation of the head can affect the cuff pressure of the endotracheal tube. We investigated the change in cuff pressure and the degree of tube displacement according to the direction of...

Descripción completa

Detalles Bibliográficos
Autor principal: Kim, Saeyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211887/
https://www.ncbi.nlm.nih.gov/pubmed/30334954
http://dx.doi.org/10.1097/MD.0000000000012702
_version_ 1783367425900675072
author Kim, Saeyoung
author_facet Kim, Saeyoung
author_sort Kim, Saeyoung
collection PubMed
description BACKGROUND: Maintaining optimal intracuff pressure of the endotracheal tube is important during airway management. Rotation of the head can affect the cuff pressure of the endotracheal tube. We investigated the change in cuff pressure and the degree of tube displacement according to the direction of head rotation (toward the same side vs opposite side of tube fixation) using a TaperGuard endotracheal tube. METHODS: We conducted a prospective study in 58 patients, aged 18 to 70 years, who underwent tympanomastoidectomy under general anesthesia. TaperGuard endotracheal tube was secured at the corner of the mouth, either on the same side as that of the head rotation (Group S, n = 29) or on the opposite side (Group O, n = 29). After endotracheal intubation, the endotracheal tube cuff pressure was set at 22 cmH(2)O in the neutral position of the head. The cuff pressure was measured again after lateral rotation of the head and readjusted to 22 cmH(2)O. In addition, the change in distance from the carina to the tip of the endotracheal tube was measured before and after the change in position. The incidences of cough, sore throat, and hoarseness were assessed at 30 minutes, 6 hours, and 24 hours after surgery. RESULTS: There were no differences between groups in terms of patient characteristics and duration of anesthesia. The change in cuff pressure after head rotation in Group S (8.07 ± 1.07 cmH(2)O) was greater than that in Group O (2.24 ± 0.95 cmH(2)O) (P < .001). In addition, 21 (72.4%) patients in Group S and no patient in Group O had pressures above 30 cmH(2)O (P < .001). Furthermore, the tube tip moved away from the carina by 8.55 ± 7.01 mm in Group S and by 2.83 ± 4.72 mm in Group O (P < .001). CONCLUSION: Fixation of the TaperGuard endotracheal tube on the side contralateral to head rotation was associated with a smaller intracuff pressure increase and lesser tube displacement compared to fixation of the tube on the ipsilateral side.
format Online
Article
Text
id pubmed-6211887
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-62118872018-11-27 Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study Kim, Saeyoung Medicine (Baltimore) Research Article BACKGROUND: Maintaining optimal intracuff pressure of the endotracheal tube is important during airway management. Rotation of the head can affect the cuff pressure of the endotracheal tube. We investigated the change in cuff pressure and the degree of tube displacement according to the direction of head rotation (toward the same side vs opposite side of tube fixation) using a TaperGuard endotracheal tube. METHODS: We conducted a prospective study in 58 patients, aged 18 to 70 years, who underwent tympanomastoidectomy under general anesthesia. TaperGuard endotracheal tube was secured at the corner of the mouth, either on the same side as that of the head rotation (Group S, n = 29) or on the opposite side (Group O, n = 29). After endotracheal intubation, the endotracheal tube cuff pressure was set at 22 cmH(2)O in the neutral position of the head. The cuff pressure was measured again after lateral rotation of the head and readjusted to 22 cmH(2)O. In addition, the change in distance from the carina to the tip of the endotracheal tube was measured before and after the change in position. The incidences of cough, sore throat, and hoarseness were assessed at 30 minutes, 6 hours, and 24 hours after surgery. RESULTS: There were no differences between groups in terms of patient characteristics and duration of anesthesia. The change in cuff pressure after head rotation in Group S (8.07 ± 1.07 cmH(2)O) was greater than that in Group O (2.24 ± 0.95 cmH(2)O) (P < .001). In addition, 21 (72.4%) patients in Group S and no patient in Group O had pressures above 30 cmH(2)O (P < .001). Furthermore, the tube tip moved away from the carina by 8.55 ± 7.01 mm in Group S and by 2.83 ± 4.72 mm in Group O (P < .001). CONCLUSION: Fixation of the TaperGuard endotracheal tube on the side contralateral to head rotation was associated with a smaller intracuff pressure increase and lesser tube displacement compared to fixation of the tube on the ipsilateral side. Wolters Kluwer Health 2018-10-19 /pmc/articles/PMC6211887/ /pubmed/30334954 http://dx.doi.org/10.1097/MD.0000000000012702 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Research Article
Kim, Saeyoung
Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title_full Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title_fullStr Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title_full_unstemmed Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title_short Comparison of the cuff pressures of a TaperGuard endotracheal tube during ipsilateral and contralateral rotation of the head: A randomized prospective study
title_sort comparison of the cuff pressures of a taperguard endotracheal tube during ipsilateral and contralateral rotation of the head: a randomized prospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6211887/
https://www.ncbi.nlm.nih.gov/pubmed/30334954
http://dx.doi.org/10.1097/MD.0000000000012702
work_keys_str_mv AT kimsaeyoung comparisonofthecuffpressuresofataperguardendotrachealtubeduringipsilateralandcontralateralrotationoftheheadarandomizedprospectivestudy