Calcium-stimulated calcitonin - The “new standard” in the diagnosis of thyroid C-cell disease - clinically relevant gender-specific cut-off levels for an “old test”

INTRODUCTION: Pentagastrin (Pg) stimulated calcitonin (sCT) was used to enhance accuracy in medullary thyroid cancer (MTC) diagnosis. As it is now unavailable, calcium (Ca) has been recommended as an alternative. The aim of this study was to define gender-specific cut-off values to predict MTC in pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Niederle, Martin B., Scheuba, Christian, Gessl, Alois, Li, Shuren, Koperek, Oskar, Bieglmayer, Christian, Riss, Philipp, Selberherr, Andreas, Niederle, Bruno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6214694/
https://www.ncbi.nlm.nih.gov/pubmed/30429678
http://dx.doi.org/10.11613/BM.2018.030710
Descripción
Sumario:INTRODUCTION: Pentagastrin (Pg) stimulated calcitonin (sCT) was used to enhance accuracy in medullary thyroid cancer (MTC) diagnosis. As it is now unavailable, calcium (Ca) has been recommended as an alternative. The aim of this study was to define gender-specific cut-off values to predict MTC in patients with elevated basal CT (bCT) following Pg-sCT and Ca-sCT stimulation and to compare the time courses of CT release during stimulation. MATERIALS AND METHODS: The stimulation tests were applied in 62 consecutive patients with thyroid nodules. Basal calcitonin was measured by chemiluminescent immunometric assay. All patients underwent thyroidectomy and bilateral central neck dissection. C-cell pathology was confirmed by histological and immunohistochemical evaluation. RESULTS: In 39 (0.63) patients MTC was documented while isolated C-cell hyperplasia (CCH) was identified in 23 (0.37) patients. Medullary thyroid cancer was predicted in males with bCT values > 43 pg/mL or sCT concentrations > 470 pg/mL (Pg-sCT) or > 1500 pg/mL (Ca-sCT), and in females with bCT concentrations > 23 pg/mL or sCT concentrations > 200 pg/mL (Pg-sCT) or > 780 pg/mL (Ca-sCT), respectively. Pg-sCT correctly predicted MTC in 16 (0.66) compared to 13 (0.54) after Ca-sCT in males and in 12 (0.80) compared to 11 (0.73) in females; without statistical significance. In patients with CCH or low tumor burden, there was a tendency of faster CT release after Ca stimulation (CT peak after 3min in > 60%) compared to patients with advanced MTC (CT peak after 3min in < 10%). CONCLUSIONS: Using gender-specific cut-off values, Ca could replace Pg to predict MTC with similar diagnostic power.