Cargando…

The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare

According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by n...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Hyun Jae, Shin, JaeWook, Cho, Jaegeol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6215558/
https://www.ncbi.nlm.nih.gov/pubmed/30420912
http://dx.doi.org/10.1155/2018/3521738
_version_ 1783368162467643392
author Baek, Hyun Jae
Shin, JaeWook
Cho, Jaegeol
author_facet Baek, Hyun Jae
Shin, JaeWook
Cho, Jaegeol
author_sort Baek, Hyun Jae
collection PubMed
description According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by normalizing the AC value to the DC value of each wavelength. Therefore, theoretically, skin color does not affect the accuracy of oxygen saturation measurement. However, if there is a direct path for the light emitting unit to the light receiving unit instead of passing through the human body, the amount of light reflected by the surface of the skin changes depending on the color of the skin. As a result, the amount of crosstalk that varies depending on the skin color affects the ratio of AC to DC, resulting in errors in the calculation of the oxygen saturation value. We made crosstalk sensors and crosstalk-free sensors and performed desaturation experiments with respiratory gas control on subjects with various skin colors to perform oxygen saturation measurements ranging from 60 to 100%. Experimental results showed that there was no difference in the measurement error of oxygen saturation according to skin color in the case of the sensor which prevented crosstalk (−0.8824 ± 2.2859 for Asian subjects, 0.6741 ± 3.2822 for Caucasian subjects, and 0.9669 ± 2.2268 for African American subjects). However, a sensor that did not prevent crosstalk showed a large error in dark skin subjects (0.8258 ± 2.1603 for Asian subjects, 0.8733 ± 1.9716 for Caucasian subjects, and −3.0591 ± 3.9925 for African Americans). Based on these results, we reiterate the importance of sensor design in the development of pulse oximeters using reflectance-type sensors.
format Online
Article
Text
id pubmed-6215558
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-62155582018-11-12 The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare Baek, Hyun Jae Shin, JaeWook Cho, Jaegeol J Healthc Eng Research Article According to the theoretical equation of the pulse oximeter expressed by the ratio of amplitude (AC) and baseline (DC) obtained from the photoplethysmographic signal of two wavelengths, the difference of the amount of light absorbed depending on the melanin indicating the skin color is canceled by normalizing the AC value to the DC value of each wavelength. Therefore, theoretically, skin color does not affect the accuracy of oxygen saturation measurement. However, if there is a direct path for the light emitting unit to the light receiving unit instead of passing through the human body, the amount of light reflected by the surface of the skin changes depending on the color of the skin. As a result, the amount of crosstalk that varies depending on the skin color affects the ratio of AC to DC, resulting in errors in the calculation of the oxygen saturation value. We made crosstalk sensors and crosstalk-free sensors and performed desaturation experiments with respiratory gas control on subjects with various skin colors to perform oxygen saturation measurements ranging from 60 to 100%. Experimental results showed that there was no difference in the measurement error of oxygen saturation according to skin color in the case of the sensor which prevented crosstalk (−0.8824 ± 2.2859 for Asian subjects, 0.6741 ± 3.2822 for Caucasian subjects, and 0.9669 ± 2.2268 for African American subjects). However, a sensor that did not prevent crosstalk showed a large error in dark skin subjects (0.8258 ± 2.1603 for Asian subjects, 0.8733 ± 1.9716 for Caucasian subjects, and −3.0591 ± 3.9925 for African Americans). Based on these results, we reiterate the importance of sensor design in the development of pulse oximeters using reflectance-type sensors. Hindawi 2018-10-21 /pmc/articles/PMC6215558/ /pubmed/30420912 http://dx.doi.org/10.1155/2018/3521738 Text en Copyright © 2018 Hyun Jae Baek et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Baek, Hyun Jae
Shin, JaeWook
Cho, Jaegeol
The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title_full The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title_fullStr The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title_full_unstemmed The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title_short The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
title_sort effect of optical crosstalk on accuracy of reflectance-type pulse oximeter for mobile healthcare
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6215558/
https://www.ncbi.nlm.nih.gov/pubmed/30420912
http://dx.doi.org/10.1155/2018/3521738
work_keys_str_mv AT baekhyunjae theeffectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare
AT shinjaewook theeffectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare
AT chojaegeol theeffectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare
AT baekhyunjae effectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare
AT shinjaewook effectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare
AT chojaegeol effectofopticalcrosstalkonaccuracyofreflectancetypepulseoximeterformobilehealthcare