Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making

Meaningful change in bone mineral density (BMD) should be equal or higher than institutional least significant change (LSC). But some facilities use vendor's LSC which is discouraged by International Society for Clinical Densitometry (ISCD). The aim of this study was to find the impact of scan...

Descripción completa

Detalles Bibliográficos
Autores principales: Fatima, Nosheen, Zaman, Maseeh Uz, Saleem, Sadaf, Hameed, Noureen, Bano, Jamila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6216730/
https://www.ncbi.nlm.nih.gov/pubmed/30505220
http://dx.doi.org/10.4103/wjnm.WJNM_69_17
_version_ 1783368302529085440
author Fatima, Nosheen
Zaman, Maseeh Uz
Saleem, Sadaf
Hameed, Noureen
Bano, Jamila
author_facet Fatima, Nosheen
Zaman, Maseeh Uz
Saleem, Sadaf
Hameed, Noureen
Bano, Jamila
author_sort Fatima, Nosheen
collection PubMed
description Meaningful change in bone mineral density (BMD) should be equal or higher than institutional least significant change (LSC). But some facilities use vendor's LSC which is discouraged by International Society for Clinical Densitometry (ISCD). The aim of this study was to find the impact of scan interpretation upon interval BMD changes using vendors and institutional LSCs. This prospective study was conducted at Joint Commission International-accredited facility of Pakistan from April–June 2017 using Hologic Discovery-A scanner. As per ISCD recommendations, precision error and LSC of two technologists were measured. Serial BMD changes such as deterioration or improvement interpreted based on vendor's and institutional LSCs were compared. Serial BMD changes in 102 patients were included, having a mean age, male:female ratio, and mean body mass index of 63 years, 94%:06%, and 29.274 kg/m(2), respectively. Mean menopausal age was 47 years and mean duration between two dual X-ray absorptiometry (DXA) studies was 3 years. BMD changes over hip were found significant in 55% and 53% cases against vendor's and institutional LSCs, respectively (nonsignificant discordance in 2%). BMD changes using vendor's and institutional LSCs were found significant over L1-4 (62% vs. 46%; discordance: 14%) and distal forearm (77% vs. 35%; discordance: 41%), respectively. Interpretations based on vendor's LSCs revealed significantly overestimated deterioration over forearm and improvement over L1-4 BMD values. We conclude that vendor's provided LSC for interpretation of serial DXA is misleading and has a significant negative impact upon patients' management. Every DXA facility must use its own LSC as per ISCD guidelines. Furthermore, ISCD must consider publishing cutoff values for LSC for distal forearm measurement.
format Online
Article
Text
id pubmed-6216730
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-62167302018-11-30 Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making Fatima, Nosheen Zaman, Maseeh Uz Saleem, Sadaf Hameed, Noureen Bano, Jamila World J Nucl Med Original Article Meaningful change in bone mineral density (BMD) should be equal or higher than institutional least significant change (LSC). But some facilities use vendor's LSC which is discouraged by International Society for Clinical Densitometry (ISCD). The aim of this study was to find the impact of scan interpretation upon interval BMD changes using vendors and institutional LSCs. This prospective study was conducted at Joint Commission International-accredited facility of Pakistan from April–June 2017 using Hologic Discovery-A scanner. As per ISCD recommendations, precision error and LSC of two technologists were measured. Serial BMD changes such as deterioration or improvement interpreted based on vendor's and institutional LSCs were compared. Serial BMD changes in 102 patients were included, having a mean age, male:female ratio, and mean body mass index of 63 years, 94%:06%, and 29.274 kg/m(2), respectively. Mean menopausal age was 47 years and mean duration between two dual X-ray absorptiometry (DXA) studies was 3 years. BMD changes over hip were found significant in 55% and 53% cases against vendor's and institutional LSCs, respectively (nonsignificant discordance in 2%). BMD changes using vendor's and institutional LSCs were found significant over L1-4 (62% vs. 46%; discordance: 14%) and distal forearm (77% vs. 35%; discordance: 41%), respectively. Interpretations based on vendor's LSCs revealed significantly overestimated deterioration over forearm and improvement over L1-4 BMD values. We conclude that vendor's provided LSC for interpretation of serial DXA is misleading and has a significant negative impact upon patients' management. Every DXA facility must use its own LSC as per ISCD guidelines. Furthermore, ISCD must consider publishing cutoff values for LSC for distal forearm measurement. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC6216730/ /pubmed/30505220 http://dx.doi.org/10.4103/wjnm.WJNM_69_17 Text en Copyright: © 2018 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Fatima, Nosheen
Zaman, Maseeh Uz
Saleem, Sadaf
Hameed, Noureen
Bano, Jamila
Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title_full Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title_fullStr Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title_full_unstemmed Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title_short Discordant interpretation of serial bone mineral density measurements by dual-energy X-ray absorptiometry using vendor's and institutional least significant changes: Serious impact on decision-making
title_sort discordant interpretation of serial bone mineral density measurements by dual-energy x-ray absorptiometry using vendor's and institutional least significant changes: serious impact on decision-making
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6216730/
https://www.ncbi.nlm.nih.gov/pubmed/30505220
http://dx.doi.org/10.4103/wjnm.WJNM_69_17
work_keys_str_mv AT fatimanosheen discordantinterpretationofserialbonemineraldensitymeasurementsbydualenergyxrayabsorptiometryusingvendorsandinstitutionalleastsignificantchangesseriousimpactondecisionmaking
AT zamanmaseehuz discordantinterpretationofserialbonemineraldensitymeasurementsbydualenergyxrayabsorptiometryusingvendorsandinstitutionalleastsignificantchangesseriousimpactondecisionmaking
AT saleemsadaf discordantinterpretationofserialbonemineraldensitymeasurementsbydualenergyxrayabsorptiometryusingvendorsandinstitutionalleastsignificantchangesseriousimpactondecisionmaking
AT hameednoureen discordantinterpretationofserialbonemineraldensitymeasurementsbydualenergyxrayabsorptiometryusingvendorsandinstitutionalleastsignificantchangesseriousimpactondecisionmaking
AT banojamila discordantinterpretationofserialbonemineraldensitymeasurementsbydualenergyxrayabsorptiometryusingvendorsandinstitutionalleastsignificantchangesseriousimpactondecisionmaking