Cargando…

Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology

OBJECTIVES: For electronic nicotine delivery systems (ENDS), also commonly called e-cigarettes, coil temperature is a factor in the potential production of toxic chemical constituents. However, data are lacking regarding the temperatures that are achieved in the latest generation of these devices. F...

Descripción completa

Detalles Bibliográficos
Autores principales: Dibaji, Seyed Ahmad Reza, Guha, Suvajyoti, Arab, Aarthi, Murray, Bruce T., Myers, Matthew R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218080/
https://www.ncbi.nlm.nih.gov/pubmed/30395592
http://dx.doi.org/10.1371/journal.pone.0206937
_version_ 1783368396767756288
author Dibaji, Seyed Ahmad Reza
Guha, Suvajyoti
Arab, Aarthi
Murray, Bruce T.
Myers, Matthew R.
author_facet Dibaji, Seyed Ahmad Reza
Guha, Suvajyoti
Arab, Aarthi
Murray, Bruce T.
Myers, Matthew R.
author_sort Dibaji, Seyed Ahmad Reza
collection PubMed
description OBJECTIVES: For electronic nicotine delivery systems (ENDS), also commonly called e-cigarettes, coil temperature is a factor in the potential production of toxic chemical constituents. However, data are lacking regarding the temperatures that are achieved in the latest generation of these devices. Fourth-generation ENDS are capable of producing heating coil temperatures well above e-liquid boiling points, and allow the user to monitor and set the heating coil temperature during a puff. In this study, we evaluate the accuracy and consistency of the temperature measurement and control settings for different brands of fourth-generation ENDS. METHODS: A study was performed using three commercially available, fourth-generation ENDS. The atomizer coil temperatures were obtained from the device (using the EScribe software) reading and from thermocouples attached to the coils during simulated puffing conditions. In addition, aerosol temperatures were measured inside the atomizer and at the mouthpiece. RESULTS: Measured temperatures varied widely across samples taken from the same brand. For example, thermocouple measurements for one unit were 40 Celsius (°C) below the 300 °C set point, while another unit of the same brand exceeded the set point by more than 100 °C. We observed a significant variation in temperature (approximately 100 °C) along the length of the coil in some cases. CONCLUSIONS: The possibility of wide temperature variation across ENDS samples, as well as variations between maximum coil temperatures and internal temperature readings, may have implications for studies that seek to determine correlations between coil temperature and toxin generation.
format Online
Article
Text
id pubmed-6218080
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62180802018-11-19 Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology Dibaji, Seyed Ahmad Reza Guha, Suvajyoti Arab, Aarthi Murray, Bruce T. Myers, Matthew R. PLoS One Research Article OBJECTIVES: For electronic nicotine delivery systems (ENDS), also commonly called e-cigarettes, coil temperature is a factor in the potential production of toxic chemical constituents. However, data are lacking regarding the temperatures that are achieved in the latest generation of these devices. Fourth-generation ENDS are capable of producing heating coil temperatures well above e-liquid boiling points, and allow the user to monitor and set the heating coil temperature during a puff. In this study, we evaluate the accuracy and consistency of the temperature measurement and control settings for different brands of fourth-generation ENDS. METHODS: A study was performed using three commercially available, fourth-generation ENDS. The atomizer coil temperatures were obtained from the device (using the EScribe software) reading and from thermocouples attached to the coils during simulated puffing conditions. In addition, aerosol temperatures were measured inside the atomizer and at the mouthpiece. RESULTS: Measured temperatures varied widely across samples taken from the same brand. For example, thermocouple measurements for one unit were 40 Celsius (°C) below the 300 °C set point, while another unit of the same brand exceeded the set point by more than 100 °C. We observed a significant variation in temperature (approximately 100 °C) along the length of the coil in some cases. CONCLUSIONS: The possibility of wide temperature variation across ENDS samples, as well as variations between maximum coil temperatures and internal temperature readings, may have implications for studies that seek to determine correlations between coil temperature and toxin generation. Public Library of Science 2018-11-05 /pmc/articles/PMC6218080/ /pubmed/30395592 http://dx.doi.org/10.1371/journal.pone.0206937 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication.
spellingShingle Research Article
Dibaji, Seyed Ahmad Reza
Guha, Suvajyoti
Arab, Aarthi
Murray, Bruce T.
Myers, Matthew R.
Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title_full Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title_fullStr Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title_full_unstemmed Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title_short Accuracy of commercial electronic nicotine delivery systems (ENDS) temperature control technology
title_sort accuracy of commercial electronic nicotine delivery systems (ends) temperature control technology
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218080/
https://www.ncbi.nlm.nih.gov/pubmed/30395592
http://dx.doi.org/10.1371/journal.pone.0206937
work_keys_str_mv AT dibajiseyedahmadreza accuracyofcommercialelectronicnicotinedeliverysystemsendstemperaturecontroltechnology
AT guhasuvajyoti accuracyofcommercialelectronicnicotinedeliverysystemsendstemperaturecontroltechnology
AT arabaarthi accuracyofcommercialelectronicnicotinedeliverysystemsendstemperaturecontroltechnology
AT murraybrucet accuracyofcommercialelectronicnicotinedeliverysystemsendstemperaturecontroltechnology
AT myersmatthewr accuracyofcommercialelectronicnicotinedeliverysystemsendstemperaturecontroltechnology