PURPOSE: We develop and assess the impact of depth-based, motion-stabilized colorization (color) of microscope-integrated optical coherence tomography (MIOCT) volumes on microsurgical performance and ability to interpret surgical volumes. METHODS: Color was applied in real-time as gradients indicati...

Descripción completa

Detalles Bibliográficos
Autores principales: Bleicher, Isaac D., Jackson-Atogi, Moseph, Viehland, Christian, Gabr, Hesham, Izatt, Joseph A., Toth, Cynthia A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218157/
https://www.ncbi.nlm.nih.gov/pubmed/30405965
http://dx.doi.org/10.1167/tvst.7.6.1
_version_ 1783368415642124288
author Bleicher, Isaac D.
Jackson-Atogi, Moseph
Viehland, Christian
Gabr, Hesham
Izatt, Joseph A.
Toth, Cynthia A.
author_facet Bleicher, Isaac D.
Jackson-Atogi, Moseph
Viehland, Christian
Gabr, Hesham
Izatt, Joseph A.
Toth, Cynthia A.
author_sort Bleicher, Isaac D.
collection PubMed
description PURPOSE: We develop and assess the impact of depth-based, motion-stabilized colorization (color) of microscope-integrated optical coherence tomography (MIOCT) volumes on microsurgical performance and ability to interpret surgical volumes. METHODS: Color was applied in real-time as gradients indicating axial position and stabilized based on calculated center of mass. In a test comparing colorization versus grayscale visualizations of prerecorded intraoperative volumes from human surgery, ophthalmologists (N = 7) were asked to identify retinal membranes, the presence of an instrument, its contact with tissue, and associated deformation of the retina. In a separate controlled trial, trainees (N = 15) performed microsurgical skills without conventional optical visualization and compared colorized versus grayscale MIOCT visualization on a stereoptic screen. Skills included thickness identification, instrument placement, and object manipulation, and were assessed based on time, performance metrics, and confidence. RESULTS: In intraoperative volume testing, colorization improved ability to differentiate membrane from retina (P < 0.01), correctly identify instrument contact with membrane (P = 0.03), and retinal deformation (P = 0.01). In model microsurgical skills testing, trainees working with colorized volumes were faster (P < 0.01) and more correct (P < 0.01) in assessments of thickness for recessed and elevated objects, were less likely to inadvertently contact a surface when approaching with an instrument (P < 0.01), and uniformly more confident (P < 0.01 for each) in conducting each skill. CONCLUSIONS: Depth-based colorization enables effective identification of retinal membranes and tissue deformation. In microsurgical skill testing, it improves user efficiency, and confidence in microscope-independent, OCT-guided model surgical maneuvers. TRANSLATIONAL RELEVANCE: Novel depth-based colorization and stabilization technology improves the use of intraoperative MIOCT.
format Online
Article
Text
id pubmed-6218157
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-62181572018-11-07 Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery Bleicher, Isaac D. Jackson-Atogi, Moseph Viehland, Christian Gabr, Hesham Izatt, Joseph A. Toth, Cynthia A. Transl Vis Sci Technol Articles PURPOSE: We develop and assess the impact of depth-based, motion-stabilized colorization (color) of microscope-integrated optical coherence tomography (MIOCT) volumes on microsurgical performance and ability to interpret surgical volumes. METHODS: Color was applied in real-time as gradients indicating axial position and stabilized based on calculated center of mass. In a test comparing colorization versus grayscale visualizations of prerecorded intraoperative volumes from human surgery, ophthalmologists (N = 7) were asked to identify retinal membranes, the presence of an instrument, its contact with tissue, and associated deformation of the retina. In a separate controlled trial, trainees (N = 15) performed microsurgical skills without conventional optical visualization and compared colorized versus grayscale MIOCT visualization on a stereoptic screen. Skills included thickness identification, instrument placement, and object manipulation, and were assessed based on time, performance metrics, and confidence. RESULTS: In intraoperative volume testing, colorization improved ability to differentiate membrane from retina (P < 0.01), correctly identify instrument contact with membrane (P = 0.03), and retinal deformation (P = 0.01). In model microsurgical skills testing, trainees working with colorized volumes were faster (P < 0.01) and more correct (P < 0.01) in assessments of thickness for recessed and elevated objects, were less likely to inadvertently contact a surface when approaching with an instrument (P < 0.01), and uniformly more confident (P < 0.01 for each) in conducting each skill. CONCLUSIONS: Depth-based colorization enables effective identification of retinal membranes and tissue deformation. In microsurgical skill testing, it improves user efficiency, and confidence in microscope-independent, OCT-guided model surgical maneuvers. TRANSLATIONAL RELEVANCE: Novel depth-based colorization and stabilization technology improves the use of intraoperative MIOCT. The Association for Research in Vision and Ophthalmology 2018-11-01 /pmc/articles/PMC6218157/ /pubmed/30405965 http://dx.doi.org/10.1167/tvst.7.6.1 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Bleicher, Isaac D.
Jackson-Atogi, Moseph
Viehland, Christian
Gabr, Hesham
Izatt, Joseph A.
Toth, Cynthia A.
Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title_full Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title_fullStr Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title_full_unstemmed Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title_short Depth-Based, Motion-Stabilized Colorization of Microscope-Integrated Optical Coherence Tomography Volumes for Microscope-Independent Microsurgery
title_sort depth-based, motion-stabilized colorization of microscope-integrated optical coherence tomography volumes for microscope-independent microsurgery
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218157/
https://www.ncbi.nlm.nih.gov/pubmed/30405965
http://dx.doi.org/10.1167/tvst.7.6.1
work_keys_str_mv AT bleicherisaacd depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery
AT jacksonatogimoseph depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery
AT viehlandchristian depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery
AT gabrhesham depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery
AT izattjosepha depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery
AT tothcynthiaa depthbasedmotionstabilizedcolorizationofmicroscopeintegratedopticalcoherencetomographyvolumesformicroscopeindependentmicrosurgery