Cargando…

Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique

INTRODUCTION: Endovascular repair (ER) as a minimally invasive approach can be effective for treating hepatic artery aneurysm (HAA) with gratifying results. Microcoil embolisation is the main technique used in ER. However, the coil embolisation of a large proper HAA (PHAA) with a very wide neck tend...

Descripción completa

Detalles Bibliográficos
Autores principales: Akasaka, Junetsu, Saguchi, Toru, Kennoki, Norifumi, Shindo, Shunya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218669/
https://www.ncbi.nlm.nih.gov/pubmed/30417134
http://dx.doi.org/10.1016/j.ejvssr.2018.09.001
_version_ 1783368505925566464
author Akasaka, Junetsu
Saguchi, Toru
Kennoki, Norifumi
Shindo, Shunya
author_facet Akasaka, Junetsu
Saguchi, Toru
Kennoki, Norifumi
Shindo, Shunya
author_sort Akasaka, Junetsu
collection PubMed
description INTRODUCTION: Endovascular repair (ER) as a minimally invasive approach can be effective for treating hepatic artery aneurysm (HAA) with gratifying results. Microcoil embolisation is the main technique used in ER. However, the coil embolisation of a large proper HAA (PHAA) with a very wide neck tends to be extremely troublesome owing to the limited length of the inflow and outflow artery. Moreover, it is difficult because of rapid blood flow in the proper hepatic artery (PHA) and the difficulty in preserving its branch flow. Microcoil embolisation of the inflow and outflow of a PHAA with the balloon occlusion technique through an originally developed single guiding sheath system was performed successfully. REPORT: A 73 year old woman was diagnosed with large PHAA (65 mm) by computed tomography examination. The PHAA was successfully treated by endovascular embolisation with microcoils using the balloon occlusion technique through a single guiding sheath system. DISCUSSION: This method is safe and effective for the treatment of a large PHAA.
format Online
Article
Text
id pubmed-6218669
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-62186692018-11-09 Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique Akasaka, Junetsu Saguchi, Toru Kennoki, Norifumi Shindo, Shunya EJVES Short Rep Case Report INTRODUCTION: Endovascular repair (ER) as a minimally invasive approach can be effective for treating hepatic artery aneurysm (HAA) with gratifying results. Microcoil embolisation is the main technique used in ER. However, the coil embolisation of a large proper HAA (PHAA) with a very wide neck tends to be extremely troublesome owing to the limited length of the inflow and outflow artery. Moreover, it is difficult because of rapid blood flow in the proper hepatic artery (PHA) and the difficulty in preserving its branch flow. Microcoil embolisation of the inflow and outflow of a PHAA with the balloon occlusion technique through an originally developed single guiding sheath system was performed successfully. REPORT: A 73 year old woman was diagnosed with large PHAA (65 mm) by computed tomography examination. The PHAA was successfully treated by endovascular embolisation with microcoils using the balloon occlusion technique through a single guiding sheath system. DISCUSSION: This method is safe and effective for the treatment of a large PHAA. Elsevier 2018-10-16 /pmc/articles/PMC6218669/ /pubmed/30417134 http://dx.doi.org/10.1016/j.ejvssr.2018.09.001 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Akasaka, Junetsu
Saguchi, Toru
Kennoki, Norifumi
Shindo, Shunya
Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title_full Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title_fullStr Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title_full_unstemmed Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title_short Coil Embolisation for Endovascular Treatment of Proper Hepatic Artery Aneurysm Using the Balloon Occlusion Technique
title_sort coil embolisation for endovascular treatment of proper hepatic artery aneurysm using the balloon occlusion technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218669/
https://www.ncbi.nlm.nih.gov/pubmed/30417134
http://dx.doi.org/10.1016/j.ejvssr.2018.09.001
work_keys_str_mv AT akasakajunetsu coilembolisationforendovasculartreatmentofproperhepaticarteryaneurysmusingtheballoonocclusiontechnique
AT saguchitoru coilembolisationforendovasculartreatmentofproperhepaticarteryaneurysmusingtheballoonocclusiontechnique
AT kennokinorifumi coilembolisationforendovasculartreatmentofproperhepaticarteryaneurysmusingtheballoonocclusiontechnique
AT shindoshunya coilembolisationforendovasculartreatmentofproperhepaticarteryaneurysmusingtheballoonocclusiontechnique