Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches

INTRODUCTION: Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause...

Descripción completa

Detalles Bibliográficos
Autores principales: Khalid, Syed Ghufran, Zhang, Jufen, Chen, Fei, Zheng, Dingchang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218731/
https://www.ncbi.nlm.nih.gov/pubmed/30425819
http://dx.doi.org/10.1155/2018/1548647
_version_ 1783368516431249408
author Khalid, Syed Ghufran
Zhang, Jufen
Chen, Fei
Zheng, Dingchang
author_facet Khalid, Syed Ghufran
Zhang, Jufen
Chen, Fei
Zheng, Dingchang
author_sort Khalid, Syed Ghufran
collection PubMed
description INTRODUCTION: Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. METHODS: The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). RESULTS: In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. CONCLUSION: This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories.
format Online
Article
Text
id pubmed-6218731
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-62187312018-11-13 Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches Khalid, Syed Ghufran Zhang, Jufen Chen, Fei Zheng, Dingchang J Healthc Eng Research Article INTRODUCTION: Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. METHODS: The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). RESULTS: In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. CONCLUSION: This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories. Hindawi 2018-10-23 /pmc/articles/PMC6218731/ /pubmed/30425819 http://dx.doi.org/10.1155/2018/1548647 Text en Copyright © 2018 Syed Ghufran Khalid et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Khalid, Syed Ghufran
Zhang, Jufen
Chen, Fei
Zheng, Dingchang
Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_full Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_fullStr Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_full_unstemmed Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_short Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches
title_sort blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218731/
https://www.ncbi.nlm.nih.gov/pubmed/30425819
http://dx.doi.org/10.1155/2018/1548647
work_keys_str_mv AT khalidsyedghufran bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT zhangjufen bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT chenfei bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches
AT zhengdingchang bloodpressureestimationusingphotoplethysmographyonlycomparisonbetweendifferentmachinelearningapproaches