Cargando…

Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model

BACKGROUND: Although magnetic resonance imaging (MRI) can provide superior detailed images of tissues without ionizing radiation, the imaging evaluation of total knee arthroplasty (TKA) complications and posttherapy changes can be limited because of abundant artifacts on MRI scans due to metallic im...

Descripción completa

Detalles Bibliográficos
Autores principales: Meng, Xiangchao, Du, Zhe, Wang, You
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218794/
https://www.ncbi.nlm.nih.gov/pubmed/30426016
http://dx.doi.org/10.1155/2018/8194670
_version_ 1783368531443712000
author Meng, Xiangchao
Du, Zhe
Wang, You
author_facet Meng, Xiangchao
Du, Zhe
Wang, You
author_sort Meng, Xiangchao
collection PubMed
description BACKGROUND: Although magnetic resonance imaging (MRI) can provide superior detailed images of tissues without ionizing radiation, the imaging evaluation of total knee arthroplasty (TKA) complications and posttherapy changes can be limited because of abundant artifacts on MRI scans due to metallic implants and endoprosthesis in limb salvage and fracture fixation. This study aimed to develop a novel model of TKA using a polyetheretherketone- (PEEK-) on-highly cross-linked polyethylene (HXLPE) implant and to investigate its feasibility for MRI monitoring of peri-implant bone formation, the healing process, signs of infection, and tumor recurrence after TKA. METHODS: Three skeletally mature goats underwent TKA with the PEEK-on-HXLPE implant. Radiographic and MRI examinations were performed at 4 weeks postoperatively. Images were analyzed for the existence of artifact interruption and postoperative changes in the bone and peripheral soft tissue. RESULTS: The results showed that PEEK and HXLPE were invisible, but the metal wires were clearly visualized on X-rays. On MRI scans, PEEK and HXLPE materials showed a low signal intensity, fine metal wires generated no obvious metal artifacts on MRI scans, and the marrow and soft tissue showed a continuous signal intensity without artifact interruption. CONCLUSIONS: This preliminary study introduced a novel model using PEEK-on-HXLPE knee implant for in vivo MRI monitoring of the region around the implant without metal artifacts. This novel model may be used to apply MRI to observe bone formation and the healing process around the prosthesis and the signs of infection and tumor recurrence after TKA. This model may be used to improve the diagnostic accuracy of postoperative complications of TKA clinically.
format Online
Article
Text
id pubmed-6218794
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-62187942018-11-13 Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model Meng, Xiangchao Du, Zhe Wang, You Biomed Res Int Research Article BACKGROUND: Although magnetic resonance imaging (MRI) can provide superior detailed images of tissues without ionizing radiation, the imaging evaluation of total knee arthroplasty (TKA) complications and posttherapy changes can be limited because of abundant artifacts on MRI scans due to metallic implants and endoprosthesis in limb salvage and fracture fixation. This study aimed to develop a novel model of TKA using a polyetheretherketone- (PEEK-) on-highly cross-linked polyethylene (HXLPE) implant and to investigate its feasibility for MRI monitoring of peri-implant bone formation, the healing process, signs of infection, and tumor recurrence after TKA. METHODS: Three skeletally mature goats underwent TKA with the PEEK-on-HXLPE implant. Radiographic and MRI examinations were performed at 4 weeks postoperatively. Images were analyzed for the existence of artifact interruption and postoperative changes in the bone and peripheral soft tissue. RESULTS: The results showed that PEEK and HXLPE were invisible, but the metal wires were clearly visualized on X-rays. On MRI scans, PEEK and HXLPE materials showed a low signal intensity, fine metal wires generated no obvious metal artifacts on MRI scans, and the marrow and soft tissue showed a continuous signal intensity without artifact interruption. CONCLUSIONS: This preliminary study introduced a novel model using PEEK-on-HXLPE knee implant for in vivo MRI monitoring of the region around the implant without metal artifacts. This novel model may be used to apply MRI to observe bone formation and the healing process around the prosthesis and the signs of infection and tumor recurrence after TKA. This model may be used to improve the diagnostic accuracy of postoperative complications of TKA clinically. Hindawi 2018-10-23 /pmc/articles/PMC6218794/ /pubmed/30426016 http://dx.doi.org/10.1155/2018/8194670 Text en Copyright © 2018 Xiangchao Meng et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Meng, Xiangchao
Du, Zhe
Wang, You
Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title_full Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title_fullStr Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title_full_unstemmed Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title_short Feasibility of Magnetic Resonance Imaging Monitoring of Postoperative Total Knee Arthroplasty without Metal Artifacts: A Preliminary Study of a Novel Implant Model
title_sort feasibility of magnetic resonance imaging monitoring of postoperative total knee arthroplasty without metal artifacts: a preliminary study of a novel implant model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6218794/
https://www.ncbi.nlm.nih.gov/pubmed/30426016
http://dx.doi.org/10.1155/2018/8194670
work_keys_str_mv AT mengxiangchao feasibilityofmagneticresonanceimagingmonitoringofpostoperativetotalkneearthroplastywithoutmetalartifactsapreliminarystudyofanovelimplantmodel
AT duzhe feasibilityofmagneticresonanceimagingmonitoringofpostoperativetotalkneearthroplastywithoutmetalartifactsapreliminarystudyofanovelimplantmodel
AT wangyou feasibilityofmagneticresonanceimagingmonitoringofpostoperativetotalkneearthroplastywithoutmetalartifactsapreliminarystudyofanovelimplantmodel