Cargando…
Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls
BACKGROUND: Ultrasound imaging has been suggested for studying the structure and function of nerves and muscles; however, reliability studies are limited to support the usage. The main aim of this study was to explore the intrarater within-session reliability of evaluating the sciatic nerve and some...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6219045/ https://www.ncbi.nlm.nih.gov/pubmed/30410724 http://dx.doi.org/10.1186/s12998-018-0215-x |
_version_ | 1783368573036527616 |
---|---|
author | Sarafraz, Hadi Hadian, Mohammad Reza Ayoobi Yazdi, Niloofar Olyaei, Gholamreza Bagheri, Hossein Jalaie, Shohreh Rasouli, Omid |
author_facet | Sarafraz, Hadi Hadian, Mohammad Reza Ayoobi Yazdi, Niloofar Olyaei, Gholamreza Bagheri, Hossein Jalaie, Shohreh Rasouli, Omid |
author_sort | Sarafraz, Hadi |
collection | PubMed |
description | BACKGROUND: Ultrasound imaging has been suggested for studying the structure and function of nerves and muscles; however, reliability studies are limited to support the usage. The main aim of this study was to explore the intrarater within-session reliability of evaluating the sciatic nerve and some related muscles morphology by ultrasound imaging. METHODS: Three B-mode images from two scans (transverse and longitudinal) were acquired from the multifidus, biceps femoris, soleus and medial gastrocnemius muscles bilaterally from 15 participants with sciatica and 15 controls in one session, 1-h apart. The data were collected from March to July 2017. Contraction ratio was measured only by longitudinal scan, while the echo intensity was measured using maximum rectangular region of interest in two scans (transverse and longitudinal) for all muscles. Cross-sectional area, direct (tracing) and indirect (ellipsoid formula) methods were used to measure the sciatic nerve. Intraclass correlation coefficient (ICC 3,1), standard error of measurement and minimal detectable change were calculated. RESULTS: Good to high ICCs (0.80–0.96) were found for muscle contraction ratio in the longitudinal scans in all the muscles in both sciatica and control groups. For echo intensity measurements ICCs ranged from moderate to high, with higher ICCs seen with the maximum region of interest in the transverse scans. The minimal detectable change values ranged between 0.11 and 0.53 cm for contraction ratio. CONCLUSIONS: Ultrasound imaging has high intrarater within-session reliability for assessing the sciatic nerve Cross-sectional area and muscle contraction ratios. Transverse scans with the maximum region of interest result in higher reliability. The sciatic Cross-sectional area is most accurately measured utilizing the direct tracing method rather than the indirect ellipsoid method. |
format | Online Article Text |
id | pubmed-6219045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-62190452018-11-08 Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls Sarafraz, Hadi Hadian, Mohammad Reza Ayoobi Yazdi, Niloofar Olyaei, Gholamreza Bagheri, Hossein Jalaie, Shohreh Rasouli, Omid Chiropr Man Therap Research BACKGROUND: Ultrasound imaging has been suggested for studying the structure and function of nerves and muscles; however, reliability studies are limited to support the usage. The main aim of this study was to explore the intrarater within-session reliability of evaluating the sciatic nerve and some related muscles morphology by ultrasound imaging. METHODS: Three B-mode images from two scans (transverse and longitudinal) were acquired from the multifidus, biceps femoris, soleus and medial gastrocnemius muscles bilaterally from 15 participants with sciatica and 15 controls in one session, 1-h apart. The data were collected from March to July 2017. Contraction ratio was measured only by longitudinal scan, while the echo intensity was measured using maximum rectangular region of interest in two scans (transverse and longitudinal) for all muscles. Cross-sectional area, direct (tracing) and indirect (ellipsoid formula) methods were used to measure the sciatic nerve. Intraclass correlation coefficient (ICC 3,1), standard error of measurement and minimal detectable change were calculated. RESULTS: Good to high ICCs (0.80–0.96) were found for muscle contraction ratio in the longitudinal scans in all the muscles in both sciatica and control groups. For echo intensity measurements ICCs ranged from moderate to high, with higher ICCs seen with the maximum region of interest in the transverse scans. The minimal detectable change values ranged between 0.11 and 0.53 cm for contraction ratio. CONCLUSIONS: Ultrasound imaging has high intrarater within-session reliability for assessing the sciatic nerve Cross-sectional area and muscle contraction ratios. Transverse scans with the maximum region of interest result in higher reliability. The sciatic Cross-sectional area is most accurately measured utilizing the direct tracing method rather than the indirect ellipsoid method. BioMed Central 2018-11-06 /pmc/articles/PMC6219045/ /pubmed/30410724 http://dx.doi.org/10.1186/s12998-018-0215-x Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Sarafraz, Hadi Hadian, Mohammad Reza Ayoobi Yazdi, Niloofar Olyaei, Gholamreza Bagheri, Hossein Jalaie, Shohreh Rasouli, Omid Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title | Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title_full | Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title_fullStr | Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title_full_unstemmed | Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title_short | Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
title_sort | test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6219045/ https://www.ncbi.nlm.nih.gov/pubmed/30410724 http://dx.doi.org/10.1186/s12998-018-0215-x |
work_keys_str_mv | AT sarafrazhadi testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT hadianmohammadreza testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT ayoobiyazdiniloofar testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT olyaeigholamreza testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT bagherihossein testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT jalaieshohreh testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols AT rasouliomid testretestreliabilityofnerveandmusclemorphometriccharacteristicsutilizingultrasoundimaginginindividualswithunilateralsciaticaandcontrols |