Cargando…

Harmonic voltage measurement error of the capacitor voltage transformer

This paper explores the mechanism for the harmonic voltage measurement error (HVME) of a capacitor voltage transformer (CVT) in a comprehensive way and develops a practical error correction method to improve the harmonic measurement performance of a CVT. The harmonic equivalent circuit (HEC) of CVTs...

Descripción completa

Detalles Bibliográficos
Autores principales: Le, Jian, Zhang, Hao, Gao, Chao, Zhou, Qian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6219776/
https://www.ncbi.nlm.nih.gov/pubmed/30399155
http://dx.doi.org/10.1371/journal.pone.0205231
_version_ 1783368716057051136
author Le, Jian
Zhang, Hao
Gao, Chao
Zhou, Qian
author_facet Le, Jian
Zhang, Hao
Gao, Chao
Zhou, Qian
author_sort Le, Jian
collection PubMed
description This paper explores the mechanism for the harmonic voltage measurement error (HVME) of a capacitor voltage transformer (CVT) in a comprehensive way and develops a practical error correction method to improve the harmonic measurement performance of a CVT. The harmonic equivalent circuit (HEC) of CVTs with different types of dampers are established and the parameter value calculation methods of the circuit elements are presented. Characteristics of the individual inherent resonance mode of the HEC, including the resonant frequency, the resonant type and the circuit elements involved, are analyzed systematically. Centered on resonance mode formulation, an universal error correction method for CVTs in measuring harmonic voltage is proposed based on the piecewise fitting of the transformation ratio. A physical experimental platform available for low-voltage CVTs is developed in laboratory, which utilizes a 10-kV harmonic generator and a step-up transformer to provide harmonic signals with high voltage level. Moreover, a novel experimental scheme for testing the HVME of high-voltage CVTs is proposed based on alternating current/direct current (AC/DC) filters. Experiments are conducted on these experimental platforms to test the HVME of a 35-kV CVT in laboratory and a 525-kV CVT in a back-to-back DC converter station. The experimental results verify the validity of the built HECs of CVTs, the resonant mode analysis results and the resonant frequency calculation method. Finally, the effectiveness of the proposed harmonic error correction method is proved by several examples.
format Online
Article
Text
id pubmed-6219776
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62197762018-11-19 Harmonic voltage measurement error of the capacitor voltage transformer Le, Jian Zhang, Hao Gao, Chao Zhou, Qian PLoS One Overview This paper explores the mechanism for the harmonic voltage measurement error (HVME) of a capacitor voltage transformer (CVT) in a comprehensive way and develops a practical error correction method to improve the harmonic measurement performance of a CVT. The harmonic equivalent circuit (HEC) of CVTs with different types of dampers are established and the parameter value calculation methods of the circuit elements are presented. Characteristics of the individual inherent resonance mode of the HEC, including the resonant frequency, the resonant type and the circuit elements involved, are analyzed systematically. Centered on resonance mode formulation, an universal error correction method for CVTs in measuring harmonic voltage is proposed based on the piecewise fitting of the transformation ratio. A physical experimental platform available for low-voltage CVTs is developed in laboratory, which utilizes a 10-kV harmonic generator and a step-up transformer to provide harmonic signals with high voltage level. Moreover, a novel experimental scheme for testing the HVME of high-voltage CVTs is proposed based on alternating current/direct current (AC/DC) filters. Experiments are conducted on these experimental platforms to test the HVME of a 35-kV CVT in laboratory and a 525-kV CVT in a back-to-back DC converter station. The experimental results verify the validity of the built HECs of CVTs, the resonant mode analysis results and the resonant frequency calculation method. Finally, the effectiveness of the proposed harmonic error correction method is proved by several examples. Public Library of Science 2018-11-06 /pmc/articles/PMC6219776/ /pubmed/30399155 http://dx.doi.org/10.1371/journal.pone.0205231 Text en © 2018 Le et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Overview
Le, Jian
Zhang, Hao
Gao, Chao
Zhou, Qian
Harmonic voltage measurement error of the capacitor voltage transformer
title Harmonic voltage measurement error of the capacitor voltage transformer
title_full Harmonic voltage measurement error of the capacitor voltage transformer
title_fullStr Harmonic voltage measurement error of the capacitor voltage transformer
title_full_unstemmed Harmonic voltage measurement error of the capacitor voltage transformer
title_short Harmonic voltage measurement error of the capacitor voltage transformer
title_sort harmonic voltage measurement error of the capacitor voltage transformer
topic Overview
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6219776/
https://www.ncbi.nlm.nih.gov/pubmed/30399155
http://dx.doi.org/10.1371/journal.pone.0205231
work_keys_str_mv AT lejian harmonicvoltagemeasurementerrorofthecapacitorvoltagetransformer
AT zhanghao harmonicvoltagemeasurementerrorofthecapacitorvoltagetransformer
AT gaochao harmonicvoltagemeasurementerrorofthecapacitorvoltagetransformer
AT zhouqian harmonicvoltagemeasurementerrorofthecapacitorvoltagetransformer