Cargando…

Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture

Alternating tangential flow (ATF) filtration has been successfully adopted as a low shear cell separation device in many perfusion‐based processes. The reverse flow per cycle is used to minimize fouling compared with tangential flow filtration. Currently, modeling of the ATF system is based on empir...

Descripción completa

Detalles Bibliográficos
Autores principales: Radoniqi, Flaka, Zhang, Hu, Bardliving, Cameron L., Shamlou, Parviz, Coffman, Jon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221016/
https://www.ncbi.nlm.nih.gov/pubmed/30080936
http://dx.doi.org/10.1002/bit.26813
_version_ 1783368938550198272
author Radoniqi, Flaka
Zhang, Hu
Bardliving, Cameron L.
Shamlou, Parviz
Coffman, Jon
author_facet Radoniqi, Flaka
Zhang, Hu
Bardliving, Cameron L.
Shamlou, Parviz
Coffman, Jon
author_sort Radoniqi, Flaka
collection PubMed
description Alternating tangential flow (ATF) filtration has been successfully adopted as a low shear cell separation device in many perfusion‐based processes. The reverse flow per cycle is used to minimize fouling compared with tangential flow filtration. Currently, modeling of the ATF system is based on empirically derived formulas, leading to oversimplification of model parameters. In this study, an experimentally validated porous computational fluid dynamic (CFD) model was used to predict localized fluid behavior and pressure profiles in the ATF membrane for both water and supernatant solutions. The results provided numerical evidence of Starling flow phenomena that has been theorized but not previously proven for the current operating parameters. Additionally, feed cross flow velocity was shown to significantly impact the localized flux distribution; higher feed cross flow rates lead to an increased localized permeate flux as well as irreversible and reversible fouling resistance. Further, the small average permeate flux values of 2 L·m(−2)·h(−1) traditionally used in perfusion bioreactor membranes lead to approximately 50% of the membrane length utilized for permeate flow during each pressure and exhaust phase, leading to a full membrane utilization during one ATF cycle. Our preliminary CFD results demonstrate that local flux and resistance distribution further elucidate the dynamics of ATF membrane fouling in a perfusion‐based system.
format Online
Article
Text
id pubmed-6221016
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-62210162018-11-15 Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture Radoniqi, Flaka Zhang, Hu Bardliving, Cameron L. Shamlou, Parviz Coffman, Jon Biotechnol Bioeng ARTICLES Alternating tangential flow (ATF) filtration has been successfully adopted as a low shear cell separation device in many perfusion‐based processes. The reverse flow per cycle is used to minimize fouling compared with tangential flow filtration. Currently, modeling of the ATF system is based on empirically derived formulas, leading to oversimplification of model parameters. In this study, an experimentally validated porous computational fluid dynamic (CFD) model was used to predict localized fluid behavior and pressure profiles in the ATF membrane for both water and supernatant solutions. The results provided numerical evidence of Starling flow phenomena that has been theorized but not previously proven for the current operating parameters. Additionally, feed cross flow velocity was shown to significantly impact the localized flux distribution; higher feed cross flow rates lead to an increased localized permeate flux as well as irreversible and reversible fouling resistance. Further, the small average permeate flux values of 2 L·m(−2)·h(−1) traditionally used in perfusion bioreactor membranes lead to approximately 50% of the membrane length utilized for permeate flow during each pressure and exhaust phase, leading to a full membrane utilization during one ATF cycle. Our preliminary CFD results demonstrate that local flux and resistance distribution further elucidate the dynamics of ATF membrane fouling in a perfusion‐based system. John Wiley and Sons Inc. 2018-09-15 2018-11 /pmc/articles/PMC6221016/ /pubmed/30080936 http://dx.doi.org/10.1002/bit.26813 Text en © 2018 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-n/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle ARTICLES
Radoniqi, Flaka
Zhang, Hu
Bardliving, Cameron L.
Shamlou, Parviz
Coffman, Jon
Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title_full Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title_fullStr Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title_full_unstemmed Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title_short Computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
title_sort computational fluid dynamic modeling of alternating tangential flow filtration for perfusion cell culture
topic ARTICLES
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221016/
https://www.ncbi.nlm.nih.gov/pubmed/30080936
http://dx.doi.org/10.1002/bit.26813
work_keys_str_mv AT radoniqiflaka computationalfluiddynamicmodelingofalternatingtangentialflowfiltrationforperfusioncellculture
AT zhanghu computationalfluiddynamicmodelingofalternatingtangentialflowfiltrationforperfusioncellculture
AT bardlivingcameronl computationalfluiddynamicmodelingofalternatingtangentialflowfiltrationforperfusioncellculture
AT shamlouparviz computationalfluiddynamicmodelingofalternatingtangentialflowfiltrationforperfusioncellculture
AT coffmanjon computationalfluiddynamicmodelingofalternatingtangentialflowfiltrationforperfusioncellculture