Cargando…

Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)

To overcome long acquisition times of Chemical Shift Imaging (CSI), a new Magnetic Resonance Spectroscopic Imaging (MRSI) technique called Reduction of Acquisition time by Partition of the sIgnal Decay in Spectroscopic Imaging (RAPID-SI) using blipped phase encoding gradients inserted during signal...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhaduri, Sourav, Clement, Patricia, Achten, Eric, Serrai, Hacene
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221315/
https://www.ncbi.nlm.nih.gov/pubmed/30403757
http://dx.doi.org/10.1371/journal.pone.0207015
_version_ 1783368994816786432
author Bhaduri, Sourav
Clement, Patricia
Achten, Eric
Serrai, Hacene
author_facet Bhaduri, Sourav
Clement, Patricia
Achten, Eric
Serrai, Hacene
author_sort Bhaduri, Sourav
collection PubMed
description To overcome long acquisition times of Chemical Shift Imaging (CSI), a new Magnetic Resonance Spectroscopic Imaging (MRSI) technique called Reduction of Acquisition time by Partition of the sIgnal Decay in Spectroscopic Imaging (RAPID-SI) using blipped phase encoding gradients inserted during signal acquisition was developed. To validate the results using RAPID-SI and to demonstrate its usefulness in terms of acquisition time and data quantification; simulations, phantom and in vivo studies were conducted, and the results were compared to standard CSI. The method was based upon the partition of a magnetic resonance spectroscopy (MRS) signal into sequential sub-signals encoded using blipped phase encoding gradients inserted during signal acquisition at a constant time interval. The RAPID-SI technique was implemented on a clinical 3 T Siemens scanner to demonstrate its clinical utility. Acceleration of data collection was performed by inserting R (R = acceleration factor) blipped gradients along a given spatial direction during data acquisition. Compared to CSI, RAPID-SI reduced acquisition time by the acceleration factor R. For example, a 2D 16x16 data set acquired in about 17 min with CSI, was reduced to approximately 2 min with the RAPID-SI (R = 8). While the SNR of the acquired RAPID-SI signal was lower compared to CSI by approximately the factor √R, it can be improved after data pre-processing and reconstruction. Compared to CSI, RAPID-SI reduces acquisition time, while preserving metabolites information. Furthermore, the method is flexible and could be combined with other acceleration methods such as Parallel Imaging.
format Online
Article
Text
id pubmed-6221315
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-62213152018-11-19 Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI) Bhaduri, Sourav Clement, Patricia Achten, Eric Serrai, Hacene PLoS One Research Article To overcome long acquisition times of Chemical Shift Imaging (CSI), a new Magnetic Resonance Spectroscopic Imaging (MRSI) technique called Reduction of Acquisition time by Partition of the sIgnal Decay in Spectroscopic Imaging (RAPID-SI) using blipped phase encoding gradients inserted during signal acquisition was developed. To validate the results using RAPID-SI and to demonstrate its usefulness in terms of acquisition time and data quantification; simulations, phantom and in vivo studies were conducted, and the results were compared to standard CSI. The method was based upon the partition of a magnetic resonance spectroscopy (MRS) signal into sequential sub-signals encoded using blipped phase encoding gradients inserted during signal acquisition at a constant time interval. The RAPID-SI technique was implemented on a clinical 3 T Siemens scanner to demonstrate its clinical utility. Acceleration of data collection was performed by inserting R (R = acceleration factor) blipped gradients along a given spatial direction during data acquisition. Compared to CSI, RAPID-SI reduced acquisition time by the acceleration factor R. For example, a 2D 16x16 data set acquired in about 17 min with CSI, was reduced to approximately 2 min with the RAPID-SI (R = 8). While the SNR of the acquired RAPID-SI signal was lower compared to CSI by approximately the factor √R, it can be improved after data pre-processing and reconstruction. Compared to CSI, RAPID-SI reduces acquisition time, while preserving metabolites information. Furthermore, the method is flexible and could be combined with other acceleration methods such as Parallel Imaging. Public Library of Science 2018-11-07 /pmc/articles/PMC6221315/ /pubmed/30403757 http://dx.doi.org/10.1371/journal.pone.0207015 Text en © 2018 Bhaduri et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bhaduri, Sourav
Clement, Patricia
Achten, Eric
Serrai, Hacene
Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title_full Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title_fullStr Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title_full_unstemmed Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title_short Reduction of Acquisition time using Partition of the sIgnal Decay in Spectroscopic Imaging technique (RAPID-SI)
title_sort reduction of acquisition time using partition of the signal decay in spectroscopic imaging technique (rapid-si)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221315/
https://www.ncbi.nlm.nih.gov/pubmed/30403757
http://dx.doi.org/10.1371/journal.pone.0207015
work_keys_str_mv AT bhadurisourav reductionofacquisitiontimeusingpartitionofthesignaldecayinspectroscopicimagingtechniquerapidsi
AT clementpatricia reductionofacquisitiontimeusingpartitionofthesignaldecayinspectroscopicimagingtechniquerapidsi
AT achteneric reductionofacquisitiontimeusingpartitionofthesignaldecayinspectroscopicimagingtechniquerapidsi
AT serraihacene reductionofacquisitiontimeusingpartitionofthesignaldecayinspectroscopicimagingtechniquerapidsi