Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength

OBJECTIVES: The aim of this study was to describe the development of morphologic and diffusion tensor imaging sequences of peripheral nerves at 7 T, using carpal tunnel syndrome (CTS) as a model system of focal nerve injury. MATERIALS AND METHODS: Morphologic images were acquired at 7 T using a bala...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmid, Annina B., Campbell, Jon, Hurley, Samuel A., Jbabdi, Saad, Andersson, Jesper L., Jenkinson, Mark, Bangerter, Neal K., Bennett, David L., Tracey, Irene, Frost, Robert, Clare, Stuart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221405/
https://www.ncbi.nlm.nih.gov/pubmed/29979328
http://dx.doi.org/10.1097/RLI.0000000000000492
_version_ 1783369017321324544
author Schmid, Annina B.
Campbell, Jon
Hurley, Samuel A.
Jbabdi, Saad
Andersson, Jesper L.
Jenkinson, Mark
Bangerter, Neal K.
Bennett, David L.
Tracey, Irene
Frost, Robert
Clare, Stuart
author_facet Schmid, Annina B.
Campbell, Jon
Hurley, Samuel A.
Jbabdi, Saad
Andersson, Jesper L.
Jenkinson, Mark
Bangerter, Neal K.
Bennett, David L.
Tracey, Irene
Frost, Robert
Clare, Stuart
author_sort Schmid, Annina B.
collection PubMed
description OBJECTIVES: The aim of this study was to describe the development of morphologic and diffusion tensor imaging sequences of peripheral nerves at 7 T, using carpal tunnel syndrome (CTS) as a model system of focal nerve injury. MATERIALS AND METHODS: Morphologic images were acquired at 7 T using a balanced steady-state free precession sequence. Diffusion tensor imaging was performed using single-shot echo-planar imaging and readout-segmented echo-planar imaging sequences. Different acquisition and postprocessing methods were compared to describe the optimal analysis pipeline. Magnetic resonance imaging parameters including cross-sectional areas, signal intensity, fractional anisotropy (FA), as well as mean, axial, and radial diffusivity were compared between patients with CTS (n = 8) and healthy controls (n = 6) using analyses of covariance corrected for age (significance set at P < 0.05). Pearson correlations with Bonferroni correction were used to determine association of magnetic resonance imaging parameters with clinical measures (significance set at P < 0.01). RESULTS: The 7 T acquisitions with high in-plane resolution (0.2 × 0.2mm) afforded detailed morphologic resolution of peripheral nerve fascicles. For diffusion tensor imaging, single-shot echo-planar imaging was more efficient than readout-segmented echo-planar imaging in terms of signal-to-noise ratio per unit scan time. Distortion artifacts were pronounced, but could be corrected during postprocessing. Registration of FA maps to the morphologic images was successful. The developed imaging and analysis pipeline identified lower median nerve FA (pisiform bone, 0.37 [SD 0.10]) and higher radial diffusivity (1.08 [0.20]) in patients with CTS compared with healthy controls (0.53 [0.06] and 0.78 [0.11], respectively, P < 0.047). Fractional anisotropy and radial diffusivity strongly correlated with patients' symptoms (r = −0.866 and 0.866, respectively, P = 0.005). CONCLUSIONS: Our data demonstrate the feasibility of morphologic and diffusion peripheral nerve imaging at 7 T. Fractional anisotropy and radial diffusivity were found to be correlates of symptom severity.
format Online
Article
Text
id pubmed-6221405
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-62214052018-11-21 Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength Schmid, Annina B. Campbell, Jon Hurley, Samuel A. Jbabdi, Saad Andersson, Jesper L. Jenkinson, Mark Bangerter, Neal K. Bennett, David L. Tracey, Irene Frost, Robert Clare, Stuart Invest Radiol Technical Note OBJECTIVES: The aim of this study was to describe the development of morphologic and diffusion tensor imaging sequences of peripheral nerves at 7 T, using carpal tunnel syndrome (CTS) as a model system of focal nerve injury. MATERIALS AND METHODS: Morphologic images were acquired at 7 T using a balanced steady-state free precession sequence. Diffusion tensor imaging was performed using single-shot echo-planar imaging and readout-segmented echo-planar imaging sequences. Different acquisition and postprocessing methods were compared to describe the optimal analysis pipeline. Magnetic resonance imaging parameters including cross-sectional areas, signal intensity, fractional anisotropy (FA), as well as mean, axial, and radial diffusivity were compared between patients with CTS (n = 8) and healthy controls (n = 6) using analyses of covariance corrected for age (significance set at P < 0.05). Pearson correlations with Bonferroni correction were used to determine association of magnetic resonance imaging parameters with clinical measures (significance set at P < 0.01). RESULTS: The 7 T acquisitions with high in-plane resolution (0.2 × 0.2mm) afforded detailed morphologic resolution of peripheral nerve fascicles. For diffusion tensor imaging, single-shot echo-planar imaging was more efficient than readout-segmented echo-planar imaging in terms of signal-to-noise ratio per unit scan time. Distortion artifacts were pronounced, but could be corrected during postprocessing. Registration of FA maps to the morphologic images was successful. The developed imaging and analysis pipeline identified lower median nerve FA (pisiform bone, 0.37 [SD 0.10]) and higher radial diffusivity (1.08 [0.20]) in patients with CTS compared with healthy controls (0.53 [0.06] and 0.78 [0.11], respectively, P < 0.047). Fractional anisotropy and radial diffusivity strongly correlated with patients' symptoms (r = −0.866 and 0.866, respectively, P = 0.005). CONCLUSIONS: Our data demonstrate the feasibility of morphologic and diffusion peripheral nerve imaging at 7 T. Fractional anisotropy and radial diffusivity were found to be correlates of symptom severity. Lippincott Williams & Wilkins 2018-12 2018-11-07 /pmc/articles/PMC6221405/ /pubmed/29979328 http://dx.doi.org/10.1097/RLI.0000000000000492 Text en Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Schmid, Annina B.
Campbell, Jon
Hurley, Samuel A.
Jbabdi, Saad
Andersson, Jesper L.
Jenkinson, Mark
Bangerter, Neal K.
Bennett, David L.
Tracey, Irene
Frost, Robert
Clare, Stuart
Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title_full Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title_fullStr Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title_full_unstemmed Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title_short Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength
title_sort feasibility of diffusion tensor and morphologic imaging of peripheral nerves at ultra-high field strength
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221405/
https://www.ncbi.nlm.nih.gov/pubmed/29979328
http://dx.doi.org/10.1097/RLI.0000000000000492
work_keys_str_mv AT schmidanninab feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT campbelljon feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT hurleysamuela feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT jbabdisaad feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT anderssonjesperl feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT jenkinsonmark feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT bangerternealk feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT bennettdavidl feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT traceyirene feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT frostrobert feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength
AT clarestuart feasibilityofdiffusiontensorandmorphologicimagingofperipheralnervesatultrahighfieldstrength