Cargando…

Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent

Background and study aims  We report the effectiveness of a newly developed plastic stent for preventing bile leakage after endoscopic ultrasonography (EUS)-guided antegrade stenting. This treatment was performed on a 59-year-old woman with malignant obstructive jaundice caused by peritoneal metasta...

Descripción completa

Detalles Bibliográficos
Autores principales: Minami, Kazuhiro, Iwasaki, Eisuke, Itoi, Takao, Fukuhara, Seiichiro, Horibe, Masayasu, Seino, Takashi, Kawasaki, Shintaro, Katayama, Tadashi, Takimoto, Yoichi, Tamagawa, Hiroki, Machida, Yujiro, Hamamoto, Yasuo, Ogata, Haruhiko, Kanai, Takanori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221811/
https://www.ncbi.nlm.nih.gov/pubmed/30410954
http://dx.doi.org/10.1055/a-0719-4861
_version_ 1783369086846107648
author Minami, Kazuhiro
Iwasaki, Eisuke
Itoi, Takao
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Yoichi
Tamagawa, Hiroki
Machida, Yujiro
Hamamoto, Yasuo
Ogata, Haruhiko
Kanai, Takanori
author_facet Minami, Kazuhiro
Iwasaki, Eisuke
Itoi, Takao
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Yoichi
Tamagawa, Hiroki
Machida, Yujiro
Hamamoto, Yasuo
Ogata, Haruhiko
Kanai, Takanori
author_sort Minami, Kazuhiro
collection PubMed
description Background and study aims  We report the effectiveness of a newly developed plastic stent for preventing bile leakage after endoscopic ultrasonography (EUS)-guided antegrade stenting. This treatment was performed on a 59-year-old woman with malignant obstructive jaundice caused by peritoneal metastasis. First, we attempted transpapillary drainage using short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography, but we could not achieve it. We then attempted EUS-guided antegrade stenting through the intrahepatic bile duct from the esophagojejunal anastomosis. We successfully inserted uncovered metallic stents for common bile duct and a newly plastic stent for hepaticojejunostomy from the antegrade approach. There were no adverse events after the treatment.
format Online
Article
Text
id pubmed-6221811
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-62218112018-11-08 Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent Minami, Kazuhiro Iwasaki, Eisuke Itoi, Takao Fukuhara, Seiichiro Horibe, Masayasu Seino, Takashi Kawasaki, Shintaro Katayama, Tadashi Takimoto, Yoichi Tamagawa, Hiroki Machida, Yujiro Hamamoto, Yasuo Ogata, Haruhiko Kanai, Takanori Endosc Int Open Background and study aims  We report the effectiveness of a newly developed plastic stent for preventing bile leakage after endoscopic ultrasonography (EUS)-guided antegrade stenting. This treatment was performed on a 59-year-old woman with malignant obstructive jaundice caused by peritoneal metastasis. First, we attempted transpapillary drainage using short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography, but we could not achieve it. We then attempted EUS-guided antegrade stenting through the intrahepatic bile duct from the esophagojejunal anastomosis. We successfully inserted uncovered metallic stents for common bile duct and a newly plastic stent for hepaticojejunostomy from the antegrade approach. There were no adverse events after the treatment. © Georg Thieme Verlag KG 2018-11 2018-11-07 /pmc/articles/PMC6221811/ /pubmed/30410954 http://dx.doi.org/10.1055/a-0719-4861 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Minami, Kazuhiro
Iwasaki, Eisuke
Itoi, Takao
Fukuhara, Seiichiro
Horibe, Masayasu
Seino, Takashi
Kawasaki, Shintaro
Katayama, Tadashi
Takimoto, Yoichi
Tamagawa, Hiroki
Machida, Yujiro
Hamamoto, Yasuo
Ogata, Haruhiko
Kanai, Takanori
Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title_full Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title_fullStr Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title_full_unstemmed Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title_short Successful EUS-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
title_sort successful eus-guided antegrade stenting for malignant severe biliary obstruction combined with a newly developed plastic stent
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6221811/
https://www.ncbi.nlm.nih.gov/pubmed/30410954
http://dx.doi.org/10.1055/a-0719-4861
work_keys_str_mv AT minamikazuhiro successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT iwasakieisuke successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT itoitakao successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT fukuharaseiichiro successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT horibemasayasu successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT seinotakashi successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT kawasakishintaro successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT katayamatadashi successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT takimotoyoichi successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT tamagawahiroki successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT machidayujiro successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT hamamotoyasuo successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT ogataharuhiko successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent
AT kanaitakanori successfuleusguidedantegradestentingformalignantseverebiliaryobstructioncombinedwithanewlydevelopedplasticstent