Cargando…

High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity

Next-generation sequencing technologies have enabled many advances across biology, with microbial ecology benefiting primarily through expanded sample sizes. Although the cost of running sequencing instruments has decreased substantially over time, the price of library preparation methods has largel...

Descripción completa

Detalles Bibliográficos
Autores principales: Minich, Jeremiah J., Humphrey, Greg, Benitez, Rodolfo A. S., Sanders, Jon, Swafford, Austin, Allen, Eric E., Knight, Rob
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6222042/
https://www.ncbi.nlm.nih.gov/pubmed/30417111
http://dx.doi.org/10.1128/mSystems.00166-18
_version_ 1783369123871326208
author Minich, Jeremiah J.
Humphrey, Greg
Benitez, Rodolfo A. S.
Sanders, Jon
Swafford, Austin
Allen, Eric E.
Knight, Rob
author_facet Minich, Jeremiah J.
Humphrey, Greg
Benitez, Rodolfo A. S.
Sanders, Jon
Swafford, Austin
Allen, Eric E.
Knight, Rob
author_sort Minich, Jeremiah J.
collection PubMed
description Next-generation sequencing technologies have enabled many advances across biology, with microbial ecology benefiting primarily through expanded sample sizes. Although the cost of running sequencing instruments has decreased substantially over time, the price of library preparation methods has largely remained unchanged. In this study, we developed a low-cost miniaturized (5-µl volume) high-throughput (384-sample) amplicon library preparation method with the Echo 550 acoustic liquid handler. Our method reduces costs of library preparation to $1.42 per sample, a 58% reduction compared to existing automated methods and a 21-fold reduction from commercial kits, without compromising sequencing success or distorting the microbial community composition analysis. We further validated the optimized method by sampling five body sites from 46 Pacific chub mackerel fish caught across 16 sampling events over seven months from the Scripps Institution of Oceanography pier in La Jolla, CA. Fish microbiome samples were processed with the miniaturized 5-µl reaction volume with 0.2 µl of genomic DNA (gDNA) and the standard 25-µl reaction volume with 1 µl of gDNA. Between the two methods, alpha diversity was highly correlated (R(2) > 0.95), while distances of technical replicates were much lower than within-body-site variation (P < 0.0001), further validating the method. The cost savings of implementing the miniaturized library preparation (going from triplicate 25-µl reactions to triplicate 5-µl reactions) are large enough to cover a MiSeq sequencing run for 768 samples while preserving accurate microbiome measurements. IMPORTANCE Reduced costs of sequencing have tremendously impacted the field of microbial ecology, allowing scientists to design more studies with larger sample sizes that often exceed 10,000 samples. Library preparation costs have not kept pace with sequencing prices, although automated liquid handling robots provide a unique opportunity to bridge this gap while also decreasing human error. Here, we take advantage of an acoustic liquid handling robot to develop a high-throughput miniaturized library preparation method of a highly cited and broadly used 16S rRNA gene amplicon reaction. We evaluate the potential negative effects of reducing the PCR volume along with varying the amount of gDNA going into the reaction. Our optimized method reduces sample-processing costs while continuing to generate a high-quality microbiome readout that is indistinguishable from the original method.
format Online
Article
Text
id pubmed-6222042
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-62220422018-11-09 High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity Minich, Jeremiah J. Humphrey, Greg Benitez, Rodolfo A. S. Sanders, Jon Swafford, Austin Allen, Eric E. Knight, Rob mSystems Methods and Protocols Next-generation sequencing technologies have enabled many advances across biology, with microbial ecology benefiting primarily through expanded sample sizes. Although the cost of running sequencing instruments has decreased substantially over time, the price of library preparation methods has largely remained unchanged. In this study, we developed a low-cost miniaturized (5-µl volume) high-throughput (384-sample) amplicon library preparation method with the Echo 550 acoustic liquid handler. Our method reduces costs of library preparation to $1.42 per sample, a 58% reduction compared to existing automated methods and a 21-fold reduction from commercial kits, without compromising sequencing success or distorting the microbial community composition analysis. We further validated the optimized method by sampling five body sites from 46 Pacific chub mackerel fish caught across 16 sampling events over seven months from the Scripps Institution of Oceanography pier in La Jolla, CA. Fish microbiome samples were processed with the miniaturized 5-µl reaction volume with 0.2 µl of genomic DNA (gDNA) and the standard 25-µl reaction volume with 1 µl of gDNA. Between the two methods, alpha diversity was highly correlated (R(2) > 0.95), while distances of technical replicates were much lower than within-body-site variation (P < 0.0001), further validating the method. The cost savings of implementing the miniaturized library preparation (going from triplicate 25-µl reactions to triplicate 5-µl reactions) are large enough to cover a MiSeq sequencing run for 768 samples while preserving accurate microbiome measurements. IMPORTANCE Reduced costs of sequencing have tremendously impacted the field of microbial ecology, allowing scientists to design more studies with larger sample sizes that often exceed 10,000 samples. Library preparation costs have not kept pace with sequencing prices, although automated liquid handling robots provide a unique opportunity to bridge this gap while also decreasing human error. Here, we take advantage of an acoustic liquid handling robot to develop a high-throughput miniaturized library preparation method of a highly cited and broadly used 16S rRNA gene amplicon reaction. We evaluate the potential negative effects of reducing the PCR volume along with varying the amount of gDNA going into the reaction. Our optimized method reduces sample-processing costs while continuing to generate a high-quality microbiome readout that is indistinguishable from the original method. American Society for Microbiology 2018-11-06 /pmc/articles/PMC6222042/ /pubmed/30417111 http://dx.doi.org/10.1128/mSystems.00166-18 Text en Copyright © 2018 Minich et al. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Methods and Protocols
Minich, Jeremiah J.
Humphrey, Greg
Benitez, Rodolfo A. S.
Sanders, Jon
Swafford, Austin
Allen, Eric E.
Knight, Rob
High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title_full High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title_fullStr High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title_full_unstemmed High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title_short High-Throughput Miniaturized 16S rRNA Amplicon Library Preparation Reduces Costs while Preserving Microbiome Integrity
title_sort high-throughput miniaturized 16s rrna amplicon library preparation reduces costs while preserving microbiome integrity
topic Methods and Protocols
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6222042/
https://www.ncbi.nlm.nih.gov/pubmed/30417111
http://dx.doi.org/10.1128/mSystems.00166-18
work_keys_str_mv AT minichjeremiahj highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT humphreygreg highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT benitezrodolfoas highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT sandersjon highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT swaffordaustin highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT allenerice highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity
AT knightrob highthroughputminiaturized16srrnaampliconlibrarypreparationreducescostswhilepreservingmicrobiomeintegrity