Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?

INTRODUCTION: Early assessment of volume status is paramount in critically ill patients. Central venous pressure (CVP) measurement and ultrasound assessment of the inferior vena cava (IVC) are both used for volume assessment in the emergency centre. Recent data is conflicting over whether there is a...

Descripción completa

Detalles Bibliográficos
Autores principales: Govender, J., Postma, I., Wood, D., Sibanda, W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: African Federation for Emergency Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6223593/
https://www.ncbi.nlm.nih.gov/pubmed/30456158
http://dx.doi.org/10.1016/j.afjem.2018.03.004
_version_ 1783369434163838976
author Govender, J.
Postma, I.
Wood, D.
Sibanda, W.
author_facet Govender, J.
Postma, I.
Wood, D.
Sibanda, W.
author_sort Govender, J.
collection PubMed
description INTRODUCTION: Early assessment of volume status is paramount in critically ill patients. Central venous pressure (CVP) measurement and ultrasound assessment of the inferior vena cava (IVC) are both used for volume assessment in the emergency centre. Recent data is conflicting over whether there is a correlation between CVP and ultrasound assessment of the IVC. METHODS: This was a retrospective review of an audit previously performed in the Emergency Unit of Ngwelezane Hospital in Kwazulu-Natal. The audit involved measuring inferior vena cava collapsibility index (IVC-CI) within 5 min of CVP measurement. In this retrospective study, audit data were analysed to determine if an association exists. RESULTS: Twenty-four patients were included. The median age of participants was 36 (IQR 42) years (95% CI 33–56). The median time to ultrasound was 18.6 (52.5) h (95% CI 7.5–36.2). The mean CVP was 13.7 ± 7.7 cm H(2)O and mean IVC-CI was 39.4 ± 17.8%. Based on a Pearson correlation test, there was a weak negative correlation between CVP and IVC-CI, which was not statistically significant (r = −0.05, n = 24, p = 0.81, 95% CI −0.5 to 0.4) for all participants. However, among females there was a moderate negative correlation between CVP and IVC-CI, which was not statistically significant (r = −0.43, n = 7, p = 0.34, 95% CI −0.9 to 0.5), while among males there was a weak positive correlation, which was not statistically significant (r = 0.16, n = 17, p = 0.53, 95% CI −0.3 to 0.6). DISCUSSION: There is no significant correlation between CVP and IVC-CI. Further validation research is required to support our preliminary findings of no significant correlation between CVP measurement and ultrasound assessment of the IVC. CVP and IVC ultrasound should be used as clinical adjuncts, and not as stand-alone measures of volume assessment.
format Online
Article
Text
id pubmed-6223593
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher African Federation for Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-62235932018-11-19 Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava? Govender, J. Postma, I. Wood, D. Sibanda, W. Afr J Emerg Med Original article INTRODUCTION: Early assessment of volume status is paramount in critically ill patients. Central venous pressure (CVP) measurement and ultrasound assessment of the inferior vena cava (IVC) are both used for volume assessment in the emergency centre. Recent data is conflicting over whether there is a correlation between CVP and ultrasound assessment of the IVC. METHODS: This was a retrospective review of an audit previously performed in the Emergency Unit of Ngwelezane Hospital in Kwazulu-Natal. The audit involved measuring inferior vena cava collapsibility index (IVC-CI) within 5 min of CVP measurement. In this retrospective study, audit data were analysed to determine if an association exists. RESULTS: Twenty-four patients were included. The median age of participants was 36 (IQR 42) years (95% CI 33–56). The median time to ultrasound was 18.6 (52.5) h (95% CI 7.5–36.2). The mean CVP was 13.7 ± 7.7 cm H(2)O and mean IVC-CI was 39.4 ± 17.8%. Based on a Pearson correlation test, there was a weak negative correlation between CVP and IVC-CI, which was not statistically significant (r = −0.05, n = 24, p = 0.81, 95% CI −0.5 to 0.4) for all participants. However, among females there was a moderate negative correlation between CVP and IVC-CI, which was not statistically significant (r = −0.43, n = 7, p = 0.34, 95% CI −0.9 to 0.5), while among males there was a weak positive correlation, which was not statistically significant (r = 0.16, n = 17, p = 0.53, 95% CI −0.3 to 0.6). DISCUSSION: There is no significant correlation between CVP and IVC-CI. Further validation research is required to support our preliminary findings of no significant correlation between CVP measurement and ultrasound assessment of the IVC. CVP and IVC ultrasound should be used as clinical adjuncts, and not as stand-alone measures of volume assessment. African Federation for Emergency Medicine 2018-09 2018-07-27 /pmc/articles/PMC6223593/ /pubmed/30456158 http://dx.doi.org/10.1016/j.afjem.2018.03.004 Text en 2018 African Federation for Emergency Medicine. Publishing services provided by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original article
Govender, J.
Postma, I.
Wood, D.
Sibanda, W.
Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title_full Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title_fullStr Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title_full_unstemmed Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title_short Is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
title_sort is there an association between central venous pressure measurement and ultrasound assessment of the inferior vena cava?
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6223593/
https://www.ncbi.nlm.nih.gov/pubmed/30456158
http://dx.doi.org/10.1016/j.afjem.2018.03.004
work_keys_str_mv AT govenderj isthereanassociationbetweencentralvenouspressuremeasurementandultrasoundassessmentoftheinferiorvenacava
AT postmai isthereanassociationbetweencentralvenouspressuremeasurementandultrasoundassessmentoftheinferiorvenacava
AT woodd isthereanassociationbetweencentralvenouspressuremeasurementandultrasoundassessmentoftheinferiorvenacava
AT sibandaw isthereanassociationbetweencentralvenouspressuremeasurementandultrasoundassessmentoftheinferiorvenacava