Cargando…

Accuracy of semi-automated versus manual localisation of liver tumours in CT-guided ablation procedures

OBJECTIVES: To compare the accuracy of liver tumour localisation in intraprocedural computed tomography (CT) images of computer-based rigid registration or non-rigid registration versus mental registration performed by interventional radiologists. METHODS: Retrospectively (2009-2017), 35 contrast-en...

Descripción completa

Detalles Bibliográficos
Autores principales: Boulkhrif, Hassan, Luu, Ha Manh, van Walsum, Theo, Moelker, Adriaan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6223880/
https://www.ncbi.nlm.nih.gov/pubmed/29802572
http://dx.doi.org/10.1007/s00330-018-5498-8
Descripción
Sumario:OBJECTIVES: To compare the accuracy of liver tumour localisation in intraprocedural computed tomography (CT) images of computer-based rigid registration or non-rigid registration versus mental registration performed by interventional radiologists. METHODS: Retrospectively (2009-2017), 35 contrast-enhanced CT (CECT) images incorporating 56 tumours, acquired during CT-guided ablation procedures and their corresponding pre-procedural diagnostic CECTs were retrieved from the picture archiving and communication system (PACS). The original intraprocedural CECTs were de-enhanced to create a virtually unenhanced CT image (VUCT). Alignment of diagnostic CECTs to their corresponding intraprocedural VUCTs was performed with non-rigid or rigid registration. Mental registration was performed by four interventional radiologists. The original intraprocedural CECT served as the reference standard. Accuracy of tumour localisation was assessed with the target registration error (TRE). Statistical differences were analysed with the Wilcoxon signed-rank test. RESULTS: Non-rigid registration failed to register two CT datasets, incorporating four tumours. In the remaining 33 datasets, non-rigid, rigid and mental registration showed a median TRE of 3.9 mm, 9.0 mm and 10.9 mm, respectively. Non-rigid registration was significantly more accurate in tumour centre localisation in comparison to rigid (p < 0.001) or mental registration (p < 0.001). Rigid registration was not statistically different from mental registration (p = 0.169). Non-rigid registration was most accurate in localising tumour centres in 42 out of 52 tumours (80.8%), while rigid and mental registration were most accurate in only seven (13.5%) and three (5.8%) tumours, respectively. CONCLUSIONS: Computer-based non-rigid registration is statistically significantly more accurate in localising liver tumours in intraprocedural unenhanced CT images in comparison to rigid registration or interventional radiologists’ mental mapping abilities. KEY POINTS: • Computer-based non-rigid registration is better (p < 0.001) in localising target tumours prior to ablation in intraprocedural CT images in comparison to rigid registration or interventional radiologists’ mental mapping abilities. • Human experts perform sub-optimal localisation of target tumours when relying solely on mental mapping during challenging CT-guided procedures. • This non-rigid registration method shows promising results as a safe alternative to intravenous contrast media in liver tumour localisation prior to ablation during CT-guided procedures.