Cargando…
Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments
A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6225739/ https://www.ncbi.nlm.nih.gov/pubmed/30407183 http://dx.doi.org/10.1107/S1600577518012717 |
_version_ | 1783369846361161728 |
---|---|
author | Kappler, J.-P. Otero, E. Li, W. Joly, L. Schmerber, G. Muller, B. Scheurer, F. Leduc, F. Gobaut, B. Poggini, L. Serrano, G. Choueikani, F. Lhotel, E. Cornia, A. Sessoli, R. Mannini, M. Arrio, M.-A. Sainctavit, Ph. Ohresser, P. |
author_facet | Kappler, J.-P. Otero, E. Li, W. Joly, L. Schmerber, G. Muller, B. Scheurer, F. Leduc, F. Gobaut, B. Poggini, L. Serrano, G. Choueikani, F. Lhotel, E. Cornia, A. Sessoli, R. Mannini, M. Arrio, M.-A. Sainctavit, Ph. Ohresser, P. |
author_sort | Kappler, J.-P. |
collection | PubMed |
description | A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the lowest achievable temperature under X-ray irradiation (T = 220 mK), the precision in controlling the temperature during measurements as well as the speed of the cooling-down and warming-up procedures. Moreover, owing to the new design of the setup, the eddy-current power is strongly reduced, allowing fast scanning of the magnetic field in XMCD experiments; these performances lead to a powerful device for X-ray spectroscopies on synchrotron-radiation beamlines facilities. |
format | Online Article Text |
id | pubmed-6225739 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-62257392018-11-19 Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments Kappler, J.-P. Otero, E. Li, W. Joly, L. Schmerber, G. Muller, B. Scheurer, F. Leduc, F. Gobaut, B. Poggini, L. Serrano, G. Choueikani, F. Lhotel, E. Cornia, A. Sessoli, R. Mannini, M. Arrio, M.-A. Sainctavit, Ph. Ohresser, P. J Synchrotron Radiat Research Papers A new ultralow-temperature setup dedicated to soft X-ray absorption spectroscopy and X-ray magnetic circular dichroism (XMCD) experiments is described. Two experiments, performed on the DEIMOS beamline (SOLEIL synchrotron), demonstrate the outstanding performance of this new platform in terms of the lowest achievable temperature under X-ray irradiation (T = 220 mK), the precision in controlling the temperature during measurements as well as the speed of the cooling-down and warming-up procedures. Moreover, owing to the new design of the setup, the eddy-current power is strongly reduced, allowing fast scanning of the magnetic field in XMCD experiments; these performances lead to a powerful device for X-ray spectroscopies on synchrotron-radiation beamlines facilities. International Union of Crystallography 2018-10-19 /pmc/articles/PMC6225739/ /pubmed/30407183 http://dx.doi.org/10.1107/S1600577518012717 Text en © J.-P. Kappler et al. 2018 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/2.0/uk/ |
spellingShingle | Research Papers Kappler, J.-P. Otero, E. Li, W. Joly, L. Schmerber, G. Muller, B. Scheurer, F. Leduc, F. Gobaut, B. Poggini, L. Serrano, G. Choueikani, F. Lhotel, E. Cornia, A. Sessoli, R. Mannini, M. Arrio, M.-A. Sainctavit, Ph. Ohresser, P. Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title | Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title_full | Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title_fullStr | Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title_full_unstemmed | Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title_short | Ultralow-temperature device dedicated to soft X-ray magnetic circular dichroism experiments |
title_sort | ultralow-temperature device dedicated to soft x-ray magnetic circular dichroism experiments |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6225739/ https://www.ncbi.nlm.nih.gov/pubmed/30407183 http://dx.doi.org/10.1107/S1600577518012717 |
work_keys_str_mv | AT kapplerjp ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT oteroe ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT liw ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT jolyl ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT schmerberg ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT mullerb ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT scheurerf ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT leducf ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT gobautb ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT pogginil ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT serranog ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT choueikanif ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT lhotele ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT corniaa ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT sessolir ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT manninim ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT arrioma ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT sainctavitph ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments AT ohresserp ultralowtemperaturedevicededicatedtosoftxraymagneticcirculardichroismexperiments |