The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise

PURPOSE: Traditional heart-rate monitoring through the use of electrocardiograms or chest-worn heart rate sensors can be challenging in certain sports or in field settings. New technologies, such as photoplethysmography (PPG), have enabled heart-rate monitoring at alternate sites. However, to date,...

Descripción completa

Detalles Bibliográficos
Autores principales: Schubert, Matthew M., Clark, Amy, De La Rosa, Annie B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6225963/
https://www.ncbi.nlm.nih.gov/pubmed/30539120
http://dx.doi.org/10.1055/a-0631-0920
_version_ 1783369882137526272
author Schubert, Matthew M.
Clark, Amy
De La Rosa, Annie B.
author_facet Schubert, Matthew M.
Clark, Amy
De La Rosa, Annie B.
author_sort Schubert, Matthew M.
collection PubMed
description PURPOSE: Traditional heart-rate monitoring through the use of electrocardiograms or chest-worn heart rate sensors can be challenging in certain sports or in field settings. New technologies, such as photoplethysmography (PPG), have enabled heart-rate monitoring at alternate sites. However, to date, the accuracy and validity of various PPG sensors has not been examined in detail. The purpose of the present investigation was to determine the validity of an arm-worn PPG sensor during yoga sequences. METHODS: Fifteen college-aged men and women participated in a ~45 min power vinyasa yoga class. During the class, participants wore Polar (®) H7 chest straps and RCX3 receivers (criterion) and Polar (®) OH1 arm bands on their upper right arm (practical). Mean differences were compared via a paired t -test, heart rate during yoga using a time*device repeated measures ANOVA, and agreement assessed with Bland-Altman analysis. RESULTS: Mean heart rates during yoga were not different (mean difference=0.76, 95% CI: –0.54 to 2.06; p =0.229). Yoga created a main effect of time on heart rate ( p <0.0001), but there was no difference between devices ( p =0.86) or interaction ( p =0.90). Mean bias±95% limits of agreement was 0.76±1.30 bpm, with a typical error of 2.42±1.49 bpm and a coefficient of variation of 1.8±1.5%. CONCLUSIONS: Results of the present investigation revealed that the Polar (®) OH1 is a valid measure of heart rate during moderate-vigorous exercise. Future validation studies should consider other exercise modes and participant characteristics.
format Online
Article
Text
id pubmed-6225963
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-62259632018-12-11 The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise Schubert, Matthew M. Clark, Amy De La Rosa, Annie B. Sports Med Int Open PURPOSE: Traditional heart-rate monitoring through the use of electrocardiograms or chest-worn heart rate sensors can be challenging in certain sports or in field settings. New technologies, such as photoplethysmography (PPG), have enabled heart-rate monitoring at alternate sites. However, to date, the accuracy and validity of various PPG sensors has not been examined in detail. The purpose of the present investigation was to determine the validity of an arm-worn PPG sensor during yoga sequences. METHODS: Fifteen college-aged men and women participated in a ~45 min power vinyasa yoga class. During the class, participants wore Polar (®) H7 chest straps and RCX3 receivers (criterion) and Polar (®) OH1 arm bands on their upper right arm (practical). Mean differences were compared via a paired t -test, heart rate during yoga using a time*device repeated measures ANOVA, and agreement assessed with Bland-Altman analysis. RESULTS: Mean heart rates during yoga were not different (mean difference=0.76, 95% CI: –0.54 to 2.06; p =0.229). Yoga created a main effect of time on heart rate ( p <0.0001), but there was no difference between devices ( p =0.86) or interaction ( p =0.90). Mean bias±95% limits of agreement was 0.76±1.30 bpm, with a typical error of 2.42±1.49 bpm and a coefficient of variation of 1.8±1.5%. CONCLUSIONS: Results of the present investigation revealed that the Polar (®) OH1 is a valid measure of heart rate during moderate-vigorous exercise. Future validation studies should consider other exercise modes and participant characteristics. © Georg Thieme Verlag KG 2018-06-17 /pmc/articles/PMC6225963/ /pubmed/30539120 http://dx.doi.org/10.1055/a-0631-0920 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Schubert, Matthew M.
Clark, Amy
De La Rosa, Annie B.
The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title_full The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title_fullStr The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title_full_unstemmed The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title_short The Polar (®) OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
title_sort polar (®) oh1 optical heart rate sensor is valid during moderate-vigorous exercise
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6225963/
https://www.ncbi.nlm.nih.gov/pubmed/30539120
http://dx.doi.org/10.1055/a-0631-0920
work_keys_str_mv AT schubertmatthewm thepolaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise
AT clarkamy thepolaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise
AT delarosaannieb thepolaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise
AT schubertmatthewm polaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise
AT clarkamy polaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise
AT delarosaannieb polaroh1opticalheartratesensorisvalidduringmoderatevigorousexercise