Cargando…
Development of the Rope-Climbing Ergometer for Physical Training and Testing
The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase i...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226072/ https://www.ncbi.nlm.nih.gov/pubmed/30539097 http://dx.doi.org/10.1055/s-0043-112335 |
_version_ | 1783369893012307968 |
---|---|
author | Arakawa, Hiroshi Kumagawa, Daisuke Fujisaki, Iwao Ozawa, Yoshiaki Ishige, Yusuke |
author_facet | Arakawa, Hiroshi Kumagawa, Daisuke Fujisaki, Iwao Ozawa, Yoshiaki Ishige, Yusuke |
author_sort | Arakawa, Hiroshi |
collection | PubMed |
description | The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase induction motor to associate the scale of the load-level setting (100 levels) with the resultant traction force. The calibration test yielded criteria values of loads (123 N at Level 0 and 1064 N at Level 100). The human test was carried out by 14 male subjects. The participants performed eight sets of 10-second maximal-effort exercises at different levels. Presumable trajectories of force, velocity, and power were obtained. The mean force increased by 161% (from 147.5 N at Level 0 to 383.7 N at Level 18), whereas the mean velocity decreased by 64.7% (from 1.87 m/s at Level 0 to 0.66 m/s at Level 18). The mean power reached its peak at Level 9 (320 W). The new rope ergometer for physical training and testing was successfully developed and characterized in this study. However, it remains to be seen whether its concurrent validity and reliability are qualifiable. |
format | Online Article Text |
id | pubmed-6226072 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-62260722018-12-11 Development of the Rope-Climbing Ergometer for Physical Training and Testing Arakawa, Hiroshi Kumagawa, Daisuke Fujisaki, Iwao Ozawa, Yoshiaki Ishige, Yusuke Sports Med Int Open The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase induction motor to associate the scale of the load-level setting (100 levels) with the resultant traction force. The calibration test yielded criteria values of loads (123 N at Level 0 and 1064 N at Level 100). The human test was carried out by 14 male subjects. The participants performed eight sets of 10-second maximal-effort exercises at different levels. Presumable trajectories of force, velocity, and power were obtained. The mean force increased by 161% (from 147.5 N at Level 0 to 383.7 N at Level 18), whereas the mean velocity decreased by 64.7% (from 1.87 m/s at Level 0 to 0.66 m/s at Level 18). The mean power reached its peak at Level 9 (320 W). The new rope ergometer for physical training and testing was successfully developed and characterized in this study. However, it remains to be seen whether its concurrent validity and reliability are qualifiable. © Georg Thieme Verlag KG 2017-07-05 /pmc/articles/PMC6226072/ /pubmed/30539097 http://dx.doi.org/10.1055/s-0043-112335 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Arakawa, Hiroshi Kumagawa, Daisuke Fujisaki, Iwao Ozawa, Yoshiaki Ishige, Yusuke Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title | Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title_full | Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title_fullStr | Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title_full_unstemmed | Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title_short | Development of the Rope-Climbing Ergometer for Physical Training and Testing |
title_sort | development of the rope-climbing ergometer for physical training and testing |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226072/ https://www.ncbi.nlm.nih.gov/pubmed/30539097 http://dx.doi.org/10.1055/s-0043-112335 |
work_keys_str_mv | AT arakawahiroshi developmentoftheropeclimbingergometerforphysicaltrainingandtesting AT kumagawadaisuke developmentoftheropeclimbingergometerforphysicaltrainingandtesting AT fujisakiiwao developmentoftheropeclimbingergometerforphysicaltrainingandtesting AT ozawayoshiaki developmentoftheropeclimbingergometerforphysicaltrainingandtesting AT ishigeyusuke developmentoftheropeclimbingergometerforphysicaltrainingandtesting |