Cargando…

Development of the Rope-Climbing Ergometer for Physical Training and Testing

The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase i...

Descripción completa

Detalles Bibliográficos
Autores principales: Arakawa, Hiroshi, Kumagawa, Daisuke, Fujisaki, Iwao, Ozawa, Yoshiaki, Ishige, Yusuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: © Georg Thieme Verlag KG 2017
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226072/
https://www.ncbi.nlm.nih.gov/pubmed/30539097
http://dx.doi.org/10.1055/s-0043-112335
_version_ 1783369893012307968
author Arakawa, Hiroshi
Kumagawa, Daisuke
Fujisaki, Iwao
Ozawa, Yoshiaki
Ishige, Yusuke
author_facet Arakawa, Hiroshi
Kumagawa, Daisuke
Fujisaki, Iwao
Ozawa, Yoshiaki
Ishige, Yusuke
author_sort Arakawa, Hiroshi
collection PubMed
description The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase induction motor to associate the scale of the load-level setting (100 levels) with the resultant traction force. The calibration test yielded criteria values of loads (123 N at Level 0 and 1064 N at Level 100). The human test was carried out by 14 male subjects. The participants performed eight sets of 10-second maximal-effort exercises at different levels. Presumable trajectories of force, velocity, and power were obtained. The mean force increased by 161% (from 147.5 N at Level 0 to 383.7 N at Level 18), whereas the mean velocity decreased by 64.7% (from 1.87 m/s at Level 0 to 0.66 m/s at Level 18). The mean power reached its peak at Level 9 (320 W). The new rope ergometer for physical training and testing was successfully developed and characterized in this study. However, it remains to be seen whether its concurrent validity and reliability are qualifiable.
format Online
Article
Text
id pubmed-6226072
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher © Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-62260722018-12-11 Development of the Rope-Climbing Ergometer for Physical Training and Testing Arakawa, Hiroshi Kumagawa, Daisuke Fujisaki, Iwao Ozawa, Yoshiaki Ishige, Yusuke Sports Med Int Open The purpose of this study was to develop and characterize a rope-climbing ergometer. A custom-made loading device that has an eddy current brake with an electrical current control circuit was developed to impose resistive load on the rope. A calibration test was first performed using a three-phase induction motor to associate the scale of the load-level setting (100 levels) with the resultant traction force. The calibration test yielded criteria values of loads (123 N at Level 0 and 1064 N at Level 100). The human test was carried out by 14 male subjects. The participants performed eight sets of 10-second maximal-effort exercises at different levels. Presumable trajectories of force, velocity, and power were obtained. The mean force increased by 161% (from 147.5 N at Level 0 to 383.7 N at Level 18), whereas the mean velocity decreased by 64.7% (from 1.87 m/s at Level 0 to 0.66 m/s at Level 18). The mean power reached its peak at Level 9 (320 W). The new rope ergometer for physical training and testing was successfully developed and characterized in this study. However, it remains to be seen whether its concurrent validity and reliability are qualifiable. © Georg Thieme Verlag KG 2017-07-05 /pmc/articles/PMC6226072/ /pubmed/30539097 http://dx.doi.org/10.1055/s-0043-112335 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Arakawa, Hiroshi
Kumagawa, Daisuke
Fujisaki, Iwao
Ozawa, Yoshiaki
Ishige, Yusuke
Development of the Rope-Climbing Ergometer for Physical Training and Testing
title Development of the Rope-Climbing Ergometer for Physical Training and Testing
title_full Development of the Rope-Climbing Ergometer for Physical Training and Testing
title_fullStr Development of the Rope-Climbing Ergometer for Physical Training and Testing
title_full_unstemmed Development of the Rope-Climbing Ergometer for Physical Training and Testing
title_short Development of the Rope-Climbing Ergometer for Physical Training and Testing
title_sort development of the rope-climbing ergometer for physical training and testing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226072/
https://www.ncbi.nlm.nih.gov/pubmed/30539097
http://dx.doi.org/10.1055/s-0043-112335
work_keys_str_mv AT arakawahiroshi developmentoftheropeclimbingergometerforphysicaltrainingandtesting
AT kumagawadaisuke developmentoftheropeclimbingergometerforphysicaltrainingandtesting
AT fujisakiiwao developmentoftheropeclimbingergometerforphysicaltrainingandtesting
AT ozawayoshiaki developmentoftheropeclimbingergometerforphysicaltrainingandtesting
AT ishigeyusuke developmentoftheropeclimbingergometerforphysicaltrainingandtesting