Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter
The purpose of this study was to examine the intra- and inter-day reliability of body composition measurements provided by a commercial multifrequency bioelectrical impedance meter. Eighteen healthy, well-trained students in physical education from the same ethnic group were assessed on four consecu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226074/ https://www.ncbi.nlm.nih.gov/pubmed/30539099 http://dx.doi.org/10.1055/s-0043-113999 |
_version_ | 1783369893489410048 |
---|---|
author | Bosquet, Laurent Niort, Thomas Poirault, Maxime |
author_facet | Bosquet, Laurent Niort, Thomas Poirault, Maxime |
author_sort | Bosquet, Laurent |
collection | PubMed |
description | The purpose of this study was to examine the intra- and inter-day reliability of body composition measurements provided by a commercial multifrequency bioelectrical impedance meter. Eighteen healthy, well-trained students in physical education from the same ethnic group were assessed on four consecutive days, both in the morning and in the evening. Indexes provided by the device were gathered in four categories: tissular, metabolic, hydric and ionic blocks. There was no systematic bias between repeated measures, regardless of time of day. Relative reliability was high to very high in the morning (0.72<ICC<0.99) and moderate to very high in the afternoon (0.61<ICC<0.99). Absolute reliability varied substantially between indexes (1.5%<SEM<15%). The minimum difference considered as real was proportionally altered, since it ranged from 4.2 to 41.5%. In conclusion, body composition assessed with a multifrequency bioelectrical impedance meter requires a highly standardized protocol and adjusting the cut-off value for each parameter to ascertain during athlete follow-up that a real change has occurred. This assessment should preferably be scheduled in the morning in order to decrease these cut-off values. |
format | Online Article Text |
id | pubmed-6226074 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-62260742018-12-11 Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter Bosquet, Laurent Niort, Thomas Poirault, Maxime Sports Med Int Open The purpose of this study was to examine the intra- and inter-day reliability of body composition measurements provided by a commercial multifrequency bioelectrical impedance meter. Eighteen healthy, well-trained students in physical education from the same ethnic group were assessed on four consecutive days, both in the morning and in the evening. Indexes provided by the device were gathered in four categories: tissular, metabolic, hydric and ionic blocks. There was no systematic bias between repeated measures, regardless of time of day. Relative reliability was high to very high in the morning (0.72<ICC<0.99) and moderate to very high in the afternoon (0.61<ICC<0.99). Absolute reliability varied substantially between indexes (1.5%<SEM<15%). The minimum difference considered as real was proportionally altered, since it ranged from 4.2 to 41.5%. In conclusion, body composition assessed with a multifrequency bioelectrical impedance meter requires a highly standardized protocol and adjusting the cut-off value for each parameter to ascertain during athlete follow-up that a real change has occurred. This assessment should preferably be scheduled in the morning in order to decrease these cut-off values. © Georg Thieme Verlag KG 2017-07-14 /pmc/articles/PMC6226074/ /pubmed/30539099 http://dx.doi.org/10.1055/s-0043-113999 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Bosquet, Laurent Niort, Thomas Poirault, Maxime Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title | Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title_full | Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title_fullStr | Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title_full_unstemmed | Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title_short | Intra- and Inter-Day Reliability of Body Composition Assessed by a Commercial Multifrequency Bioelectrical Impedance Meter |
title_sort | intra- and inter-day reliability of body composition assessed by a commercial multifrequency bioelectrical impedance meter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226074/ https://www.ncbi.nlm.nih.gov/pubmed/30539099 http://dx.doi.org/10.1055/s-0043-113999 |
work_keys_str_mv | AT bosquetlaurent intraandinterdayreliabilityofbodycompositionassessedbyacommercialmultifrequencybioelectricalimpedancemeter AT niortthomas intraandinterdayreliabilityofbodycompositionassessedbyacommercialmultifrequencybioelectricalimpedancemeter AT poiraultmaxime intraandinterdayreliabilityofbodycompositionassessedbyacommercialmultifrequencybioelectricalimpedancemeter |