Cargando…

Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections

Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categori...

Descripción completa

Detalles Bibliográficos
Autores principales: Siadat, Hakimeh, Najafi, Hossain, Alikhasi, Marzieh, Falahi, Babak, Beyabanaki, Elaheh, Zayeri, Farid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231156/
https://www.ncbi.nlm.nih.gov/pubmed/30443303
http://dx.doi.org/10.15171/joddd.2018.028
_version_ 1783370175533285376
author Siadat, Hakimeh
Najafi, Hossain
Alikhasi, Marzieh
Falahi, Babak
Beyabanaki, Elaheh
Zayeri, Farid
author_facet Siadat, Hakimeh
Najafi, Hossain
Alikhasi, Marzieh
Falahi, Babak
Beyabanaki, Elaheh
Zayeri, Farid
author_sort Siadat, Hakimeh
collection PubMed
description Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups.
format Online
Article
Text
id pubmed-6231156
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-62311562018-11-15 Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections Siadat, Hakimeh Najafi, Hossain Alikhasi, Marzieh Falahi, Babak Beyabanaki, Elaheh Zayeri, Farid J Dent Res Dent Clin Dent Prospects Original Article Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups. Tabriz University of Medical Sciences 2018 2018-09-18 /pmc/articles/PMC6231156/ /pubmed/30443303 http://dx.doi.org/10.15171/joddd.2018.028 Text en © 2018 Siadat et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Siadat, Hakimeh
Najafi, Hossain
Alikhasi, Marzieh
Falahi, Babak
Beyabanaki, Elaheh
Zayeri, Farid
Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title_full Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title_fullStr Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title_full_unstemmed Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title_short Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
title_sort effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231156/
https://www.ncbi.nlm.nih.gov/pubmed/30443303
http://dx.doi.org/10.15171/joddd.2018.028
work_keys_str_mv AT siadathakimeh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections
AT najafihossain effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections
AT alikhasimarzieh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections
AT falahibabak effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections
AT beyabanakielaheh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections
AT zayerifarid effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections