Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections
Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categori...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231156/ https://www.ncbi.nlm.nih.gov/pubmed/30443303 http://dx.doi.org/10.15171/joddd.2018.028 |
_version_ | 1783370175533285376 |
---|---|
author | Siadat, Hakimeh Najafi, Hossain Alikhasi, Marzieh Falahi, Babak Beyabanaki, Elaheh Zayeri, Farid |
author_facet | Siadat, Hakimeh Najafi, Hossain Alikhasi, Marzieh Falahi, Babak Beyabanaki, Elaheh Zayeri, Farid |
author_sort | Siadat, Hakimeh |
collection | PubMed |
description | Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups. |
format | Online Article Text |
id | pubmed-6231156 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-62311562018-11-15 Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections Siadat, Hakimeh Najafi, Hossain Alikhasi, Marzieh Falahi, Babak Beyabanaki, Elaheh Zayeri, Farid J Dent Res Dent Clin Dent Prospects Original Article Background. The implant connection type might affect microleakage and screw loosening in two-piece implants. The aim of this study was to measure microleakage and screw loosening of two connections of Noble Biocare implant system before and after cyclic loading. Methods. Twelve samples were categorized into two groups: external hexagon (Branemark) and internal hexagon connection (Noble Active) and two implants as controls. The abutments were tightened to a 35 Ncm torque. Initial torque loss (ITL) was measured five minutes after retightening the abutment, using a digital torque wrench. The samples were covered with putty material to the abutment‒implant junction. Customized metal crowns with 45° inclinations were placed on the abutments and cyclic loading was performed accordingly. Thereafter, the secondary torque loss (STL) was measured. Microleakage test was also performed. Data were analyzed with Mann-Whitney and Wilcoxon tests (α=0.05). Results. There were no statistically significant differences between the two phases of gamma counting between and within two groups (P>0.05). However, STL after cyclic loading was less than ITL in both groups (P=0.042). Conclusion. Connection type and cyclic loading had no significant effect on microleakage. Furthermore, the internal connection had less TL as compared to the external connection. In addition, the STLs were less than ITLs in both groups. Tabriz University of Medical Sciences 2018 2018-09-18 /pmc/articles/PMC6231156/ /pubmed/30443303 http://dx.doi.org/10.15171/joddd.2018.028 Text en © 2018 Siadat et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Siadat, Hakimeh Najafi, Hossain Alikhasi, Marzieh Falahi, Babak Beyabanaki, Elaheh Zayeri, Farid Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title | Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title_full | Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title_fullStr | Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title_full_unstemmed | Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title_short | Effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
title_sort | effect of lateral oblique cyclic loading on microleakage and screw loosening of implants with different connections |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231156/ https://www.ncbi.nlm.nih.gov/pubmed/30443303 http://dx.doi.org/10.15171/joddd.2018.028 |
work_keys_str_mv | AT siadathakimeh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections AT najafihossain effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections AT alikhasimarzieh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections AT falahibabak effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections AT beyabanakielaheh effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections AT zayerifarid effectoflateralobliquecyclicloadingonmicroleakageandscrewlooseningofimplantswithdifferentconnections |