Cargando…

QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients

We developed an automated approach for QRS complex detection and QRS duration (QRSd) measurement that can effectively analyze multichannel electrocardiograms (MECGs) acquired during abnormal conduction and pacing in heart failure and cardiac resynchronization therapy (CRT) patients to enable the use...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231906/
https://www.ncbi.nlm.nih.gov/pubmed/30443440
http://dx.doi.org/10.1109/JTEHM.2018.2844195
_version_ 1783370325630648320
collection PubMed
description We developed an automated approach for QRS complex detection and QRS duration (QRSd) measurement that can effectively analyze multichannel electrocardiograms (MECGs) acquired during abnormal conduction and pacing in heart failure and cardiac resynchronization therapy (CRT) patients to enable the use of MECGs to characterize cardiac activation in such patients. The algorithms use MECGs acquired with a custom 53-electrode investigational body surface mapping system and were validated using previously collected data from 58 CRT patients. An expert cohort analyzed the same data to determine algorithm accuracy and error. The algorithms: 1) detect QRS complexes; 2) identify complexes of the most prevalent morphology and morphologic outliers; and 3) determine the array-specific (i.e., anterior and posterior) and global QRS complex onsets, offsets, and durations for the detected complexes. The QRS complex detection algorithm had a positive predictivity and sensitivity of ≥96% for complex detection and classification. The absolute QRSd error was 17 ± 14 ms, or 12%, for array-specific QRSd and 12 ± 10 ms, or 8%, for global QRSd. The absolute global QRSd error (12 ms) was less than the interobserver variation in that measurement (15 ± 10 ms). The sensitivity, positive predictivity, and error of the algorithms were similar to the values reported for current state-of-the-art algorithms designed for and limited to simpler data sets and conduction patterns and within the variation found in clinical 12-lead ECG QRSd measurement techniques. These new algorithms permit accurate, real-time analysis of QRS complex features in MECGs in patients with conduction disorders and/or pacing.
format Online
Article
Text
id pubmed-6231906
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-62319062018-11-15 QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients IEEE J Transl Eng Health Med Article We developed an automated approach for QRS complex detection and QRS duration (QRSd) measurement that can effectively analyze multichannel electrocardiograms (MECGs) acquired during abnormal conduction and pacing in heart failure and cardiac resynchronization therapy (CRT) patients to enable the use of MECGs to characterize cardiac activation in such patients. The algorithms use MECGs acquired with a custom 53-electrode investigational body surface mapping system and were validated using previously collected data from 58 CRT patients. An expert cohort analyzed the same data to determine algorithm accuracy and error. The algorithms: 1) detect QRS complexes; 2) identify complexes of the most prevalent morphology and morphologic outliers; and 3) determine the array-specific (i.e., anterior and posterior) and global QRS complex onsets, offsets, and durations for the detected complexes. The QRS complex detection algorithm had a positive predictivity and sensitivity of ≥96% for complex detection and classification. The absolute QRSd error was 17 ± 14 ms, or 12%, for array-specific QRSd and 12 ± 10 ms, or 8%, for global QRSd. The absolute global QRSd error (12 ms) was less than the interobserver variation in that measurement (15 ± 10 ms). The sensitivity, positive predictivity, and error of the algorithms were similar to the values reported for current state-of-the-art algorithms designed for and limited to simpler data sets and conduction patterns and within the variation found in clinical 12-lead ECG QRSd measurement techniques. These new algorithms permit accurate, real-time analysis of QRS complex features in MECGs in patients with conduction disorders and/or pacing. IEEE 2018-06-05 /pmc/articles/PMC6231906/ /pubmed/30443440 http://dx.doi.org/10.1109/JTEHM.2018.2844195 Text en 2168-2372 © 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
spellingShingle Article
QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title_full QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title_fullStr QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title_full_unstemmed QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title_short QRS Complex Detection and Measurement Algorithms for Multichannel ECGs in Cardiac Resynchronization Therapy Patients
title_sort qrs complex detection and measurement algorithms for multichannel ecgs in cardiac resynchronization therapy patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6231906/
https://www.ncbi.nlm.nih.gov/pubmed/30443440
http://dx.doi.org/10.1109/JTEHM.2018.2844195
work_keys_str_mv AT qrscomplexdetectionandmeasurementalgorithmsformultichannelecgsincardiacresynchronizationtherapypatients
AT qrscomplexdetectionandmeasurementalgorithmsformultichannelecgsincardiacresynchronizationtherapypatients
AT qrscomplexdetectionandmeasurementalgorithmsformultichannelecgsincardiacresynchronizationtherapypatients
AT qrscomplexdetectionandmeasurementalgorithmsformultichannelecgsincardiacresynchronizationtherapypatients