Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure.
There is a lack of well-established criteria for the specific measurement of fibrinolytic parameters. On behalf of the SSC, the subcommittee on Fibrinolysis started a process to develop criteria for the specific measurement of fibrinolytic variables. This report describes the criteria for the specif...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Communications and Publications Division (CPD) of the IFCC
2001
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6232859/ https://www.ncbi.nlm.nih.gov/pubmed/30429724 |
_version_ | 1783370470422216704 |
---|---|
author | Meijer, Piet Hanss, Michel Christensen, Ulla Wiman, Bjorn Kluft, Kees |
author_facet | Meijer, Piet Hanss, Michel Christensen, Ulla Wiman, Bjorn Kluft, Kees |
author_sort | Meijer, Piet |
collection | PubMed |
description | There is a lack of well-established criteria for the specific measurement of fibrinolytic parameters. On behalf of the SSC, the subcommittee on Fibrinolysis started a process to develop criteria for the specific measurement of fibrinolytic variables. This report describes the criteria for the specific measurement of plasmin inhibitor activity. In summary, a plasma deficient in plasmin inhibitor should show an activity close to 0%. Plasma containing only the non-plasminogen binding form of plasmin inhibitor should show an activity nearby the activity of a plasma deficient for plasmin inhibitor. Other inhibitors of plasmin, like a 2 -macroglobulin, antithrombin in the presence of heparin, and C1-esterase inhibitor should not interfere in the assay at the level usually found in pathological conditions or at the higher normal level. |
format | Online Article Text |
id | pubmed-6232859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2001 |
publisher | The Communications and Publications Division (CPD) of the IFCC |
record_format | MEDLINE/PubMed |
spelling | pubmed-62328592018-11-14 Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. Meijer, Piet Hanss, Michel Christensen, Ulla Wiman, Bjorn Kluft, Kees EJIFCC Data Paper There is a lack of well-established criteria for the specific measurement of fibrinolytic parameters. On behalf of the SSC, the subcommittee on Fibrinolysis started a process to develop criteria for the specific measurement of fibrinolytic variables. This report describes the criteria for the specific measurement of plasmin inhibitor activity. In summary, a plasma deficient in plasmin inhibitor should show an activity close to 0%. Plasma containing only the non-plasminogen binding form of plasmin inhibitor should show an activity nearby the activity of a plasma deficient for plasmin inhibitor. Other inhibitors of plasmin, like a 2 -macroglobulin, antithrombin in the presence of heparin, and C1-esterase inhibitor should not interfere in the assay at the level usually found in pathological conditions or at the higher normal level. The Communications and Publications Division (CPD) of the IFCC 2001-07-22 /pmc/articles/PMC6232859/ /pubmed/30429724 Text en Copyright © 2001 International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Data Paper Meijer, Piet Hanss, Michel Christensen, Ulla Wiman, Bjorn Kluft, Kees Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title | Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title_full | Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title_fullStr | Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title_full_unstemmed | Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title_short | Criteria for the Specific Measurement of Plasmin Inhibitor Activity Using an Enzymatic Procedure. |
title_sort | criteria for the specific measurement of plasmin inhibitor activity using an enzymatic procedure. |
topic | Data Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6232859/ https://www.ncbi.nlm.nih.gov/pubmed/30429724 |
work_keys_str_mv | AT meijerpiet criteriaforthespecificmeasurementofplasmininhibitoractivityusinganenzymaticprocedure AT hanssmichel criteriaforthespecificmeasurementofplasmininhibitoractivityusinganenzymaticprocedure AT christensenulla criteriaforthespecificmeasurementofplasmininhibitoractivityusinganenzymaticprocedure AT wimanbjorn criteriaforthespecificmeasurementofplasmininhibitoractivityusinganenzymaticprocedure AT kluftkees criteriaforthespecificmeasurementofplasmininhibitoractivityusinganenzymaticprocedure |