Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions
BACKGROUND AND OBJECTIVES: Strength of medial olivocochlear reflex can be measured reliably using contralateral inhibition of distortion product otoacoustic emissions (DPOAEs) when its fine structure is considered. However, measurement of fine structure of DPOAE is difficult with clinical equipment....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Audiological Society and Korean Otological Society
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6233937/ https://www.ncbi.nlm.nih.gov/pubmed/30126264 http://dx.doi.org/10.7874/jao.2018.00038 |
_version_ | 1783370625697447936 |
---|---|
author | Kalaiah, Mohan Kumar Lasrado, Alina Pinto, Nikita Shastri, Usha |
author_facet | Kalaiah, Mohan Kumar Lasrado, Alina Pinto, Nikita Shastri, Usha |
author_sort | Kalaiah, Mohan Kumar |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: Strength of medial olivocochlear reflex can be measured reliably using contralateral inhibition of distortion product otoacoustic emissions (DPOAEs) when its fine structure is considered. However, measurement of fine structure of DPOAE is difficult with clinical equipment. Thus, this study investigated the clinically relevant test-retest reliability of contralateral inhibition of DPOAEs. SUBJECTS AND METHODS: Twenty-six young adults with normal hearing sensitivity participated. DPOAEs were recorded at 27 discrete f2 frequencies between 800 Hz and 8,000 Hz at frequency resolution of 8 points per octave with and without contralateral white noise presented at 50 dB SPL. To check for short term inter-session reliability, contralateral inhibition of DPOAEs were recorded in three sessions, two recording sessions on first day separated by 30 minutes and third time after one week of the first session. Within each session, DPOAEs were recorded twice in single probe-fit condition to test for intra-session reliability. RESULTS: Cronbach’s alpha was calculated having poor reliability (α≤ 0.7) of contralateral inhibition of DPOAEs in both intra-session and inter-session conditions for most of the tested frequencies. 95% confidence intervals of contralateral inhibition magnitude also showed large variability. CONCLUSIONS: The current results showed that though DPOAE amplitudes were highly reliable across sessions, amount of inhibition of DPOAEs was not reliable when DPOAEs were measured at discrete frequencies. These findings are concurrent with the literature. |
format | Online Article Text |
id | pubmed-6233937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Audiological Society and Korean Otological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-62339372018-11-16 Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions Kalaiah, Mohan Kumar Lasrado, Alina Pinto, Nikita Shastri, Usha J Audiol Otol Original Article BACKGROUND AND OBJECTIVES: Strength of medial olivocochlear reflex can be measured reliably using contralateral inhibition of distortion product otoacoustic emissions (DPOAEs) when its fine structure is considered. However, measurement of fine structure of DPOAE is difficult with clinical equipment. Thus, this study investigated the clinically relevant test-retest reliability of contralateral inhibition of DPOAEs. SUBJECTS AND METHODS: Twenty-six young adults with normal hearing sensitivity participated. DPOAEs were recorded at 27 discrete f2 frequencies between 800 Hz and 8,000 Hz at frequency resolution of 8 points per octave with and without contralateral white noise presented at 50 dB SPL. To check for short term inter-session reliability, contralateral inhibition of DPOAEs were recorded in three sessions, two recording sessions on first day separated by 30 minutes and third time after one week of the first session. Within each session, DPOAEs were recorded twice in single probe-fit condition to test for intra-session reliability. RESULTS: Cronbach’s alpha was calculated having poor reliability (α≤ 0.7) of contralateral inhibition of DPOAEs in both intra-session and inter-session conditions for most of the tested frequencies. 95% confidence intervals of contralateral inhibition magnitude also showed large variability. CONCLUSIONS: The current results showed that though DPOAE amplitudes were highly reliable across sessions, amount of inhibition of DPOAEs was not reliable when DPOAEs were measured at discrete frequencies. These findings are concurrent with the literature. The Korean Audiological Society and Korean Otological Society 2018-10 2018-08-22 /pmc/articles/PMC6233937/ /pubmed/30126264 http://dx.doi.org/10.7874/jao.2018.00038 Text en Copyright © 2018 The Korean Audiological Society and Korean Otological Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kalaiah, Mohan Kumar Lasrado, Alina Pinto, Nikita Shastri, Usha Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title | Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title_full | Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title_fullStr | Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title_full_unstemmed | Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title_short | Short Term Test-Retest Reliability of Contralateral Inhibition of Distortion Product Otoacoustic Emissions |
title_sort | short term test-retest reliability of contralateral inhibition of distortion product otoacoustic emissions |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6233937/ https://www.ncbi.nlm.nih.gov/pubmed/30126264 http://dx.doi.org/10.7874/jao.2018.00038 |
work_keys_str_mv | AT kalaiahmohankumar shorttermtestretestreliabilityofcontralateralinhibitionofdistortionproductotoacousticemissions AT lasradoalina shorttermtestretestreliabilityofcontralateralinhibitionofdistortionproductotoacousticemissions AT pintonikita shorttermtestretestreliabilityofcontralateralinhibitionofdistortionproductotoacousticemissions AT shastriusha shorttermtestretestreliabilityofcontralateralinhibitionofdistortionproductotoacousticemissions |