Cargando…
Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform
BACKGROUND: There is growing interest in the potential for wearable and mobile devices to deliver clinically relevant information in real-world contexts. However, there is limited information on their acceptability and barriers to long-term use in people living with psychosis. OBJECTIVE: This study...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6234334/ https://www.ncbi.nlm.nih.gov/pubmed/30377146 http://dx.doi.org/10.2196/mhealth.8292 |
_version_ | 1783370680094425088 |
---|---|
author | Meyer, Nicholas Kerz, Maximilian Folarin, Amos Joyce, Dan W Jackson, Richard Karr, Chris Dobson, Richard MacCabe, James |
author_facet | Meyer, Nicholas Kerz, Maximilian Folarin, Amos Joyce, Dan W Jackson, Richard Karr, Chris Dobson, Richard MacCabe, James |
author_sort | Meyer, Nicholas |
collection | PubMed |
description | BACKGROUND: There is growing interest in the potential for wearable and mobile devices to deliver clinically relevant information in real-world contexts. However, there is limited information on their acceptability and barriers to long-term use in people living with psychosis. OBJECTIVE: This study aimed to describe the development, implementation, feasibility, acceptability, and user experiences of the Sleepsight platform, which harnesses consumer wearable devices and smartphones for the passive and unobtrusive capture of sleep and rest-activity profiles in people with schizophrenia living in their homes. METHODS: A total of 15 outpatients with a diagnosis of schizophrenia used a consumer wrist-worn device and smartphone to continuously and remotely gather rest-activity profiles over 2 months. Once-daily sleep and self-rated symptom diaries were also collected via a smartphone app. Adherence with the devices and smartphone app, end-of-study user experiences, and agreement between subjective and objective sleep measures were analyzed. Thresholds for acceptability were set at a wear time or diary response rate of 70% or greater. RESULTS: Overall, 14 out of 15 participants completed the study. In individuals with a mild to moderate symptom severity at baseline (mean total Positive and Negative Syndrome Scale score 58.4 [SD 14.4]), we demonstrated high rates of engagement with the wearable device (all participants meeting acceptability criteria), sleep diary, and symptom diary (93% and 86% meeting criteria, respectively), with negative symptoms being associated with lower diary completion rate. The end-of-study usability and acceptability questionnaire and qualitative analysis identified facilitators and barriers to long-term use, and paranoia with study devices was not a significant barrier to engagement. Comparison between sleep diary and wearable estimated sleep times showed good correspondence (ρ=0.50, P<.001). CONCLUSIONS: Extended use of wearable and mobile technologies are acceptable to people with schizophrenia living in a community setting. In the future, these technologies may allow predictive, objective markers of clinical status, including early markers of impending relapse. |
format | Online Article Text |
id | pubmed-6234334 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-62343342018-12-10 Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform Meyer, Nicholas Kerz, Maximilian Folarin, Amos Joyce, Dan W Jackson, Richard Karr, Chris Dobson, Richard MacCabe, James JMIR Mhealth Uhealth Original Paper BACKGROUND: There is growing interest in the potential for wearable and mobile devices to deliver clinically relevant information in real-world contexts. However, there is limited information on their acceptability and barriers to long-term use in people living with psychosis. OBJECTIVE: This study aimed to describe the development, implementation, feasibility, acceptability, and user experiences of the Sleepsight platform, which harnesses consumer wearable devices and smartphones for the passive and unobtrusive capture of sleep and rest-activity profiles in people with schizophrenia living in their homes. METHODS: A total of 15 outpatients with a diagnosis of schizophrenia used a consumer wrist-worn device and smartphone to continuously and remotely gather rest-activity profiles over 2 months. Once-daily sleep and self-rated symptom diaries were also collected via a smartphone app. Adherence with the devices and smartphone app, end-of-study user experiences, and agreement between subjective and objective sleep measures were analyzed. Thresholds for acceptability were set at a wear time or diary response rate of 70% or greater. RESULTS: Overall, 14 out of 15 participants completed the study. In individuals with a mild to moderate symptom severity at baseline (mean total Positive and Negative Syndrome Scale score 58.4 [SD 14.4]), we demonstrated high rates of engagement with the wearable device (all participants meeting acceptability criteria), sleep diary, and symptom diary (93% and 86% meeting criteria, respectively), with negative symptoms being associated with lower diary completion rate. The end-of-study usability and acceptability questionnaire and qualitative analysis identified facilitators and barriers to long-term use, and paranoia with study devices was not a significant barrier to engagement. Comparison between sleep diary and wearable estimated sleep times showed good correspondence (ρ=0.50, P<.001). CONCLUSIONS: Extended use of wearable and mobile technologies are acceptable to people with schizophrenia living in a community setting. In the future, these technologies may allow predictive, objective markers of clinical status, including early markers of impending relapse. JMIR Publications 2018-10-30 /pmc/articles/PMC6234334/ /pubmed/30377146 http://dx.doi.org/10.2196/mhealth.8292 Text en ©Nicholas Meyer, Maximilian Kerz, Amos Folarin, Dan W Joyce, Richard Jackson, Chris Karr, Richard Dobson, James MacCabe. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 30.10.2018. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Meyer, Nicholas Kerz, Maximilian Folarin, Amos Joyce, Dan W Jackson, Richard Karr, Chris Dobson, Richard MacCabe, James Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title | Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title_full | Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title_fullStr | Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title_full_unstemmed | Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title_short | Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform |
title_sort | capturing rest-activity profiles in schizophrenia using wearable and mobile technologies: development, implementation, feasibility, and acceptability of a remote monitoring platform |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6234334/ https://www.ncbi.nlm.nih.gov/pubmed/30377146 http://dx.doi.org/10.2196/mhealth.8292 |
work_keys_str_mv | AT meyernicholas capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT kerzmaximilian capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT folarinamos capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT joycedanw capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT jacksonrichard capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT karrchris capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT dobsonrichard capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform AT maccabejames capturingrestactivityprofilesinschizophreniausingwearableandmobiletechnologiesdevelopmentimplementationfeasibilityandacceptabilityofaremotemonitoringplatform |