Cargando…

Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy

Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsushita, Katsuyuki, Golgotiu, Kirsti, Orton, Daniel J., Smith, Richard D., Rodland, Karin D., Piehowski, Paul D., Hutchens, Michael P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6235460/
https://www.ncbi.nlm.nih.gov/pubmed/30371667
http://dx.doi.org/10.3791/58206
_version_ 1783370874752073728
author Matsushita, Katsuyuki
Golgotiu, Kirsti
Orton, Daniel J.
Smith, Richard D.
Rodland, Karin D.
Piehowski, Paul D.
Hutchens, Michael P.
author_facet Matsushita, Katsuyuki
Golgotiu, Kirsti
Orton, Daniel J.
Smith, Richard D.
Rodland, Karin D.
Piehowski, Paul D.
Hutchens, Michael P.
author_sort Matsushita, Katsuyuki
collection PubMed
description Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)-dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation.
format Online
Article
Text
id pubmed-6235460
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-62354602019-10-11 Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy Matsushita, Katsuyuki Golgotiu, Kirsti Orton, Daniel J. Smith, Richard D. Rodland, Karin D. Piehowski, Paul D. Hutchens, Michael P. J Vis Exp Biology Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)-dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation. MyJove Corporation 2018-10-11 /pmc/articles/PMC6235460/ /pubmed/30371667 http://dx.doi.org/10.3791/58206 Text en Copyright © 2018, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Biology
Matsushita, Katsuyuki
Golgotiu, Kirsti
Orton, Daniel J.
Smith, Richard D.
Rodland, Karin D.
Piehowski, Paul D.
Hutchens, Michael P.
Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title_full Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title_fullStr Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title_full_unstemmed Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title_short Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy
title_sort micropuncture of bowman's space in mice facilitated by 2 photon microscopy
topic Biology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6235460/
https://www.ncbi.nlm.nih.gov/pubmed/30371667
http://dx.doi.org/10.3791/58206
work_keys_str_mv AT matsushitakatsuyuki micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT golgotiukirsti micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT ortondanielj micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT smithrichardd micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT rodlandkarind micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT piehowskipauld micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy
AT hutchensmichaelp micropunctureofbowmansspaceinmicefacilitatedby2photonmicroscopy