Cargando…
Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging
The performances of the pixelated CsI(Tl) scintillation screens based on oxidized silicon micro-pore array templates with different CsI(Tl) micro-column shapes and array structures in X-ray imaging were simulated using the Geant4 Monte Carlo simulation code. The shapes of the micro-columns include s...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6235952/ https://www.ncbi.nlm.nih.gov/pubmed/30429504 http://dx.doi.org/10.1038/s41598-018-34852-3 |
_version_ | 1783370940223062016 |
---|---|
author | Chen, Hui Gu, Mu Liu, Xiaolin Zhang, Juannan Liu, Bo Huang, Shiming Ni, Chen |
author_facet | Chen, Hui Gu, Mu Liu, Xiaolin Zhang, Juannan Liu, Bo Huang, Shiming Ni, Chen |
author_sort | Chen, Hui |
collection | PubMed |
description | The performances of the pixelated CsI(Tl) scintillation screens based on oxidized silicon micro-pore array templates with different CsI(Tl) micro-column shapes and array structures in X-ray imaging were simulated using the Geant4 Monte Carlo simulation code. The shapes of the micro-columns include square, hexagonal and circular, and the array structures include square and hexagonal arrangements. The pitch size of the pixelated CsI(Tl) scintillation screens was set to 4 µm, and the incident X-ray energy was set to 20 keV. The ratios of the number of scintillation photons that propagate along the CsI(Tl) micro-columns to the total number of scintillation photons of the micro-columns gradually decrease with the increase in total reflection time on the lateral surfaces of the micro-columns. However, these ratios are closely related to the shapes of the micro-columns and the incident positions of X-ray on the cross-sections of the micro-columns, especially for the circular micro-column. The sequence of bottom light outputs stimulated by a uniform flood field of X-ray from high to low corresponds to the circular, square and hexagonal CsI(Tl) micro-columns with the same cross-section areas. In addition, all spatial resolutions in terms of modulation transfer functions (MTFs) for the pixelated CsI(Tl) scintillation screens with square and hexagonal array structures are over 100 lp/mm. However, the resolution for the pixelated screen with the hexagonal array structure is approximately 8.5% higher than that for the screen with the square array structure. Moreover, the former screen has a higher detective quantum efficiency (DQE) than the latter screen at the same thickness. The pixelated CsI(Tl) scintillation screen with circular micro-column and hexagonal array structure in X-ray imaging has superior performance compared to other pixelated screens in this work. |
format | Online Article Text |
id | pubmed-6235952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-62359522018-11-20 Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging Chen, Hui Gu, Mu Liu, Xiaolin Zhang, Juannan Liu, Bo Huang, Shiming Ni, Chen Sci Rep Article The performances of the pixelated CsI(Tl) scintillation screens based on oxidized silicon micro-pore array templates with different CsI(Tl) micro-column shapes and array structures in X-ray imaging were simulated using the Geant4 Monte Carlo simulation code. The shapes of the micro-columns include square, hexagonal and circular, and the array structures include square and hexagonal arrangements. The pitch size of the pixelated CsI(Tl) scintillation screens was set to 4 µm, and the incident X-ray energy was set to 20 keV. The ratios of the number of scintillation photons that propagate along the CsI(Tl) micro-columns to the total number of scintillation photons of the micro-columns gradually decrease with the increase in total reflection time on the lateral surfaces of the micro-columns. However, these ratios are closely related to the shapes of the micro-columns and the incident positions of X-ray on the cross-sections of the micro-columns, especially for the circular micro-column. The sequence of bottom light outputs stimulated by a uniform flood field of X-ray from high to low corresponds to the circular, square and hexagonal CsI(Tl) micro-columns with the same cross-section areas. In addition, all spatial resolutions in terms of modulation transfer functions (MTFs) for the pixelated CsI(Tl) scintillation screens with square and hexagonal array structures are over 100 lp/mm. However, the resolution for the pixelated screen with the hexagonal array structure is approximately 8.5% higher than that for the screen with the square array structure. Moreover, the former screen has a higher detective quantum efficiency (DQE) than the latter screen at the same thickness. The pixelated CsI(Tl) scintillation screen with circular micro-column and hexagonal array structure in X-ray imaging has superior performance compared to other pixelated screens in this work. Nature Publishing Group UK 2018-11-14 /pmc/articles/PMC6235952/ /pubmed/30429504 http://dx.doi.org/10.1038/s41598-018-34852-3 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Chen, Hui Gu, Mu Liu, Xiaolin Zhang, Juannan Liu, Bo Huang, Shiming Ni, Chen Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title | Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title_full | Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title_fullStr | Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title_full_unstemmed | Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title_short | Simulated performances of pixelated CsI(Tl) scintillation screens with different micro-column shapes and array structures in X-ray imaging |
title_sort | simulated performances of pixelated csi(tl) scintillation screens with different micro-column shapes and array structures in x-ray imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6235952/ https://www.ncbi.nlm.nih.gov/pubmed/30429504 http://dx.doi.org/10.1038/s41598-018-34852-3 |
work_keys_str_mv | AT chenhui simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT gumu simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT liuxiaolin simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT zhangjuannan simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT liubo simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT huangshiming simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging AT nichen simulatedperformancesofpixelatedcsitlscintillationscreenswithdifferentmicrocolumnshapesandarraystructuresinxrayimaging |