Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236827/ https://www.ncbi.nlm.nih.gov/pubmed/30338922 http://dx.doi.org/10.1002/acm2.12460 |
_version_ | 1783371089014947840 |
---|---|
author | Moliner, Gilles Sorro, Lise Verstraet, Rodolfe Daviau, Paul Alexandre Casas, Mélanie Piron, Bérengère Dubois, Karine Debrigode, Charles Barrau, Corinne Bons, Françoise Greffier, Joël |
author_facet | Moliner, Gilles Sorro, Lise Verstraet, Rodolfe Daviau, Paul Alexandre Casas, Mélanie Piron, Bérengère Dubois, Karine Debrigode, Charles Barrau, Corinne Bons, Françoise Greffier, Joël |
author_sort | Moliner, Gilles |
collection | PubMed |
description | PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to three analysis protocols. The detection sensitivity to technical errors of each individual or combined measurement processes was studied by inserting collimator, dose and MLC opening error into five head and neck and five prostate initial treatment plans. A total of 220 plans were created and 660 analyses were conducted by comparing measurements to error free planned dose matrix. RESULTS: For head and neck localization, collimator errors could be detected from 2° for AC and 3° for PDIP. Dose and MLC errors could be detected from 2% and 0.5 mm for AC and PDIP. Depending on the analysis protocol, the detection sensitivity of total simulated errors ranged from 54% to 88% for AC vs 40% to 74% for PDIP and 58% to 92% for the combined process. For the prostate localization, collimator errors could be detected from 4° for AC while they could not be detected by PDIP. Dose and MLC errors could be detected from 3% and 0.5 mm for AC and PDIP. The detection sensitivity of total simulated errors ranged from 30% to 56% for AC vs 16% to 38% for PDIP and 30% to 58% for combined process. CONCLUSION: The combined use of the two measurement processes did not statistically improve the detectability of technical errors compared to use of single process. |
format | Online Article Text |
id | pubmed-6236827 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-62368272018-11-20 Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy Moliner, Gilles Sorro, Lise Verstraet, Rodolfe Daviau, Paul Alexandre Casas, Mélanie Piron, Bérengère Dubois, Karine Debrigode, Charles Barrau, Corinne Bons, Françoise Greffier, Joël J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to three analysis protocols. The detection sensitivity to technical errors of each individual or combined measurement processes was studied by inserting collimator, dose and MLC opening error into five head and neck and five prostate initial treatment plans. A total of 220 plans were created and 660 analyses were conducted by comparing measurements to error free planned dose matrix. RESULTS: For head and neck localization, collimator errors could be detected from 2° for AC and 3° for PDIP. Dose and MLC errors could be detected from 2% and 0.5 mm for AC and PDIP. Depending on the analysis protocol, the detection sensitivity of total simulated errors ranged from 54% to 88% for AC vs 40% to 74% for PDIP and 58% to 92% for the combined process. For the prostate localization, collimator errors could be detected from 4° for AC while they could not be detected by PDIP. Dose and MLC errors could be detected from 3% and 0.5 mm for AC and PDIP. The detection sensitivity of total simulated errors ranged from 30% to 56% for AC vs 16% to 38% for PDIP and 30% to 58% for combined process. CONCLUSION: The combined use of the two measurement processes did not statistically improve the detectability of technical errors compared to use of single process. John Wiley and Sons Inc. 2018-10-19 /pmc/articles/PMC6236827/ /pubmed/30338922 http://dx.doi.org/10.1002/acm2.12460 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Moliner, Gilles Sorro, Lise Verstraet, Rodolfe Daviau, Paul Alexandre Casas, Mélanie Piron, Bérengère Dubois, Karine Debrigode, Charles Barrau, Corinne Bons, Françoise Greffier, Joël Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title | Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title_full | Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title_fullStr | Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title_full_unstemmed | Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title_short | Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
title_sort | assessment of combined use of arccheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236827/ https://www.ncbi.nlm.nih.gov/pubmed/30338922 http://dx.doi.org/10.1002/acm2.12460 |
work_keys_str_mv | AT molinergilles assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT sorrolise assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT verstraetrodolfe assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT daviaupaulalexandre assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT casasmelanie assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT pironberengere assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT duboiskarine assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT debrigodecharles assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT barraucorinne assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT bonsfrancoise assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy AT greffierjoel assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy |