Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy

PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to...

Descripción completa

Detalles Bibliográficos
Autores principales: Moliner, Gilles, Sorro, Lise, Verstraet, Rodolfe, Daviau, Paul Alexandre, Casas, Mélanie, Piron, Bérengère, Dubois, Karine, Debrigode, Charles, Barrau, Corinne, Bons, Françoise, Greffier, Joël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236827/
https://www.ncbi.nlm.nih.gov/pubmed/30338922
http://dx.doi.org/10.1002/acm2.12460
_version_ 1783371089014947840
author Moliner, Gilles
Sorro, Lise
Verstraet, Rodolfe
Daviau, Paul Alexandre
Casas, Mélanie
Piron, Bérengère
Dubois, Karine
Debrigode, Charles
Barrau, Corinne
Bons, Françoise
Greffier, Joël
author_facet Moliner, Gilles
Sorro, Lise
Verstraet, Rodolfe
Daviau, Paul Alexandre
Casas, Mélanie
Piron, Bérengère
Dubois, Karine
Debrigode, Charles
Barrau, Corinne
Bons, Françoise
Greffier, Joël
author_sort Moliner, Gilles
collection PubMed
description PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to three analysis protocols. The detection sensitivity to technical errors of each individual or combined measurement processes was studied by inserting collimator, dose and MLC opening error into five head and neck and five prostate initial treatment plans. A total of 220 plans were created and 660 analyses were conducted by comparing measurements to error free planned dose matrix. RESULTS: For head and neck localization, collimator errors could be detected from 2° for AC and 3° for PDIP. Dose and MLC errors could be detected from 2% and 0.5 mm for AC and PDIP. Depending on the analysis protocol, the detection sensitivity of total simulated errors ranged from 54% to 88% for AC vs 40% to 74% for PDIP and 58% to 92% for the combined process. For the prostate localization, collimator errors could be detected from 4° for AC while they could not be detected by PDIP. Dose and MLC errors could be detected from 3% and 0.5 mm for AC and PDIP. The detection sensitivity of total simulated errors ranged from 30% to 56% for AC vs 16% to 38% for PDIP and 30% to 58% for combined process. CONCLUSION: The combined use of the two measurement processes did not statistically improve the detectability of technical errors compared to use of single process.
format Online
Article
Text
id pubmed-6236827
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-62368272018-11-20 Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy Moliner, Gilles Sorro, Lise Verstraet, Rodolfe Daviau, Paul Alexandre Casas, Mélanie Piron, Bérengère Dubois, Karine Debrigode, Charles Barrau, Corinne Bons, Françoise Greffier, Joël J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To assess the efficiency of combined use of ArcCheck(®) detector (AC) and portal dosimetry (PDIP) for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy. MATERIALS AND METHODS: Measurement processes were studied with the Gamma index method according to three analysis protocols. The detection sensitivity to technical errors of each individual or combined measurement processes was studied by inserting collimator, dose and MLC opening error into five head and neck and five prostate initial treatment plans. A total of 220 plans were created and 660 analyses were conducted by comparing measurements to error free planned dose matrix. RESULTS: For head and neck localization, collimator errors could be detected from 2° for AC and 3° for PDIP. Dose and MLC errors could be detected from 2% and 0.5 mm for AC and PDIP. Depending on the analysis protocol, the detection sensitivity of total simulated errors ranged from 54% to 88% for AC vs 40% to 74% for PDIP and 58% to 92% for the combined process. For the prostate localization, collimator errors could be detected from 4° for AC while they could not be detected by PDIP. Dose and MLC errors could be detected from 3% and 0.5 mm for AC and PDIP. The detection sensitivity of total simulated errors ranged from 30% to 56% for AC vs 16% to 38% for PDIP and 30% to 58% for combined process. CONCLUSION: The combined use of the two measurement processes did not statistically improve the detectability of technical errors compared to use of single process. John Wiley and Sons Inc. 2018-10-19 /pmc/articles/PMC6236827/ /pubmed/30338922 http://dx.doi.org/10.1002/acm2.12460 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Moliner, Gilles
Sorro, Lise
Verstraet, Rodolfe
Daviau, Paul Alexandre
Casas, Mélanie
Piron, Bérengère
Dubois, Karine
Debrigode, Charles
Barrau, Corinne
Bons, Françoise
Greffier, Joël
Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title_full Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title_fullStr Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title_full_unstemmed Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title_short Assessment of combined use of ArcCheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
title_sort assessment of combined use of arccheck(®) detector and portal dosimetry for delivery quality assurance of head and neck and prostate volumetric‐modulated arc therapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236827/
https://www.ncbi.nlm.nih.gov/pubmed/30338922
http://dx.doi.org/10.1002/acm2.12460
work_keys_str_mv AT molinergilles assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT sorrolise assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT verstraetrodolfe assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT daviaupaulalexandre assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT casasmelanie assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT pironberengere assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT duboiskarine assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT debrigodecharles assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT barraucorinne assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT bonsfrancoise assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy
AT greffierjoel assessmentofcombineduseofarccheckdetectorandportaldosimetryfordeliveryqualityassuranceofheadandneckandprostatevolumetricmodulatedarctherapy