Cargando…
A clinical 3D/4D CBCT‐based treatment dose monitoring system
To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx‐Dose) reconstruction system based on three‐dimensional (3D)/four‐dimensional (4D)‐cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236849/ https://www.ncbi.nlm.nih.gov/pubmed/30306710 http://dx.doi.org/10.1002/acm2.12474 |
_version_ | 1783371094028189696 |
---|---|
author | Qin, An Gersten, David Liang, Jian Liu, Qiang Grill, Inga Guerrero, Thomas Stevens, Craig Yan, Di |
author_facet | Qin, An Gersten, David Liang, Jian Liu, Qiang Grill, Inga Guerrero, Thomas Stevens, Craig Yan, Di |
author_sort | Qin, An |
collection | PubMed |
description | To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx‐Dose) reconstruction system based on three‐dimensional (3D)/four‐dimensional (4D)‐cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for lung cancer patient treated by stereotactic body radiation therapy (SBRT). This system integrates with our treatment planning system (TPS), Linacs recording and verification system (R&V), and CBCT imaging system, consisting of three modules: Treatment Schedule Monitoring module (TSM), pseudo‐CT Generating module (PCG), and Treatment Dose Reconstruction/evaluation module (TDR). TSM watches the treatment progress in the R&V system and triggers the PCG module when new CBCT is available. PCG retrieves the CBCTs and performs planning CT to CBCT deformable registration (DIR) to generate pseudo‐CT. The 4D‐CBCT images are taken for target localization and correction in lung cancer patient before treatment. To take full advantage of the valuable information carried by 4D‐CBCT, a novel phase‐matching DIR scheme was developed to generate 4D pseudo‐CT images for 4D dose reconstruction. Finally, TDR module creates TPS scripts to automate Tx‐Dose calculation on the pseudo‐CT images. Both initial quantitative commissioning and patient‐specific qualitative quality assurance of the DIR tool were utilized to ensure the DIR quality. The treatment doses of ten patients (six SBRT‐lung, two head and neck (HN), one breast and one prostate cancer patients) were retrospectively constructed and evaluated. The target registration error (mean ± STD: 1.05 ± 1.13 mm) of the DIR tool is comparable to the interobserver uncertainty (0.88 ± 1.31 mm) evaluated by a publically available lung‐landmarks dataset. For lung SBRT patients, the D(99) of the final cumulative Tx‐Dose of GTV is 93.8 ± 5.5% (83.7–100.1%) of the originally planned D(99). CTV D(99) decreases by 3% and mean ipsilateral parotid dose increases by 11.5% for one of the two HN patients. In conclusion, we have demonstrated the feasibility and effectiveness of a treatment dose verification system in our clinical setting. |
format | Online Article Text |
id | pubmed-6236849 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-62368492018-11-20 A clinical 3D/4D CBCT‐based treatment dose monitoring system Qin, An Gersten, David Liang, Jian Liu, Qiang Grill, Inga Guerrero, Thomas Stevens, Craig Yan, Di J Appl Clin Med Phys Radiation Oncology Physics To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx‐Dose) reconstruction system based on three‐dimensional (3D)/four‐dimensional (4D)‐cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for lung cancer patient treated by stereotactic body radiation therapy (SBRT). This system integrates with our treatment planning system (TPS), Linacs recording and verification system (R&V), and CBCT imaging system, consisting of three modules: Treatment Schedule Monitoring module (TSM), pseudo‐CT Generating module (PCG), and Treatment Dose Reconstruction/evaluation module (TDR). TSM watches the treatment progress in the R&V system and triggers the PCG module when new CBCT is available. PCG retrieves the CBCTs and performs planning CT to CBCT deformable registration (DIR) to generate pseudo‐CT. The 4D‐CBCT images are taken for target localization and correction in lung cancer patient before treatment. To take full advantage of the valuable information carried by 4D‐CBCT, a novel phase‐matching DIR scheme was developed to generate 4D pseudo‐CT images for 4D dose reconstruction. Finally, TDR module creates TPS scripts to automate Tx‐Dose calculation on the pseudo‐CT images. Both initial quantitative commissioning and patient‐specific qualitative quality assurance of the DIR tool were utilized to ensure the DIR quality. The treatment doses of ten patients (six SBRT‐lung, two head and neck (HN), one breast and one prostate cancer patients) were retrospectively constructed and evaluated. The target registration error (mean ± STD: 1.05 ± 1.13 mm) of the DIR tool is comparable to the interobserver uncertainty (0.88 ± 1.31 mm) evaluated by a publically available lung‐landmarks dataset. For lung SBRT patients, the D(99) of the final cumulative Tx‐Dose of GTV is 93.8 ± 5.5% (83.7–100.1%) of the originally planned D(99). CTV D(99) decreases by 3% and mean ipsilateral parotid dose increases by 11.5% for one of the two HN patients. In conclusion, we have demonstrated the feasibility and effectiveness of a treatment dose verification system in our clinical setting. John Wiley and Sons Inc. 2018-10-10 /pmc/articles/PMC6236849/ /pubmed/30306710 http://dx.doi.org/10.1002/acm2.12474 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Qin, An Gersten, David Liang, Jian Liu, Qiang Grill, Inga Guerrero, Thomas Stevens, Craig Yan, Di A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title | A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title_full | A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title_fullStr | A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title_full_unstemmed | A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title_short | A clinical 3D/4D CBCT‐based treatment dose monitoring system |
title_sort | clinical 3d/4d cbct‐based treatment dose monitoring system |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236849/ https://www.ncbi.nlm.nih.gov/pubmed/30306710 http://dx.doi.org/10.1002/acm2.12474 |
work_keys_str_mv | AT qinan aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT gerstendavid aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT liangjian aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT liuqiang aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT grillinga aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT guerrerothomas aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT stevenscraig aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT yandi aclinical3d4dcbctbasedtreatmentdosemonitoringsystem AT qinan clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT gerstendavid clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT liangjian clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT liuqiang clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT grillinga clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT guerrerothomas clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT stevenscraig clinical3d4dcbctbasedtreatmentdosemonitoringsystem AT yandi clinical3d4dcbctbasedtreatmentdosemonitoringsystem |