Cargando…

Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus

OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiogra...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Hua, Chen, Qiang, Zhang, Gui-Can, Chen, Liang-Wan, Xu, Fan, Zhang, Jia-Xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6237790/
https://www.ncbi.nlm.nih.gov/pubmed/29952360
http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001
_version_ 1783371241222045696
author Cao, Hua
Chen, Qiang
Zhang, Gui-Can
Chen, Liang-Wan
Xu, Fan
Zhang, Jia-Xin
author_facet Cao, Hua
Chen, Qiang
Zhang, Gui-Can
Chen, Liang-Wan
Xu, Fan
Zhang, Jia-Xin
author_sort Cao, Hua
collection PubMed
description OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion using an occluder delivered via a delivery sheath introduced via femoral vein access without the use of X-ray equipment in 12 PDA patients. RESULTS: PDA occlusion was successfully performed in all 12 patients. The procedure duration ranged from 30 to 110 min (50.4±22.8 min), and the size of the implanted occluder ranged from 12 to 20 mm (15.2±2.8 mm). No occluder migration, residual shunt, or thrombotic complications were observed in the perioperative period. There was no clinical death, hemolysis, infection, or embolism during patients’ hospitalization and the follow-up period. CONCLUSION: Stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion without the use of X-ray equipment is a safe and effective procedure.
format Online
Article
Text
id pubmed-6237790
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-62377902018-11-19 Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus Cao, Hua Chen, Qiang Zhang, Gui-Can Chen, Liang-Wan Xu, Fan Zhang, Jia-Xin Anatol J Cardiol Original Investigation OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion using an occluder delivered via a delivery sheath introduced via femoral vein access without the use of X-ray equipment in 12 PDA patients. RESULTS: PDA occlusion was successfully performed in all 12 patients. The procedure duration ranged from 30 to 110 min (50.4±22.8 min), and the size of the implanted occluder ranged from 12 to 20 mm (15.2±2.8 mm). No occluder migration, residual shunt, or thrombotic complications were observed in the perioperative period. There was no clinical death, hemolysis, infection, or embolism during patients’ hospitalization and the follow-up period. CONCLUSION: Stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion without the use of X-ray equipment is a safe and effective procedure. Kare Publishing 2018-07 2018-06-11 /pmc/articles/PMC6237790/ /pubmed/29952360 http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001 Text en Copyright: © 2018 Turkish Society of Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Original Investigation
Cao, Hua
Chen, Qiang
Zhang, Gui-Can
Chen, Liang-Wan
Xu, Fan
Zhang, Jia-Xin
Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title_full Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title_fullStr Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title_full_unstemmed Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title_short Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
title_sort clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6237790/
https://www.ncbi.nlm.nih.gov/pubmed/29952360
http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001
work_keys_str_mv AT caohua clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus
AT chenqiang clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus
AT zhangguican clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus
AT chenliangwan clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus
AT xufan clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus
AT zhangjiaxin clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus