Cargando…
Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus
OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiogra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6237790/ https://www.ncbi.nlm.nih.gov/pubmed/29952360 http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001 |
_version_ | 1783371241222045696 |
---|---|
author | Cao, Hua Chen, Qiang Zhang, Gui-Can Chen, Liang-Wan Xu, Fan Zhang, Jia-Xin |
author_facet | Cao, Hua Chen, Qiang Zhang, Gui-Can Chen, Liang-Wan Xu, Fan Zhang, Jia-Xin |
author_sort | Cao, Hua |
collection | PubMed |
description | OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion using an occluder delivered via a delivery sheath introduced via femoral vein access without the use of X-ray equipment in 12 PDA patients. RESULTS: PDA occlusion was successfully performed in all 12 patients. The procedure duration ranged from 30 to 110 min (50.4±22.8 min), and the size of the implanted occluder ranged from 12 to 20 mm (15.2±2.8 mm). No occluder migration, residual shunt, or thrombotic complications were observed in the perioperative period. There was no clinical death, hemolysis, infection, or embolism during patients’ hospitalization and the follow-up period. CONCLUSION: Stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion without the use of X-ray equipment is a safe and effective procedure. |
format | Online Article Text |
id | pubmed-6237790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Kare Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-62377902018-11-19 Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus Cao, Hua Chen, Qiang Zhang, Gui-Can Chen, Liang-Wan Xu, Fan Zhang, Jia-Xin Anatol J Cardiol Original Investigation OBJECTIVE: We aimed to investigate the feasibility and safety of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus (PDA) without the use of X-ray equipment. METHODS: From January to December 2015, we performed stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion using an occluder delivered via a delivery sheath introduced via femoral vein access without the use of X-ray equipment in 12 PDA patients. RESULTS: PDA occlusion was successfully performed in all 12 patients. The procedure duration ranged from 30 to 110 min (50.4±22.8 min), and the size of the implanted occluder ranged from 12 to 20 mm (15.2±2.8 mm). No occluder migration, residual shunt, or thrombotic complications were observed in the perioperative period. There was no clinical death, hemolysis, infection, or embolism during patients’ hospitalization and the follow-up period. CONCLUSION: Stand-alone transthoracic echocardiography-guided percutaneous PDA occlusion without the use of X-ray equipment is a safe and effective procedure. Kare Publishing 2018-07 2018-06-11 /pmc/articles/PMC6237790/ /pubmed/29952360 http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001 Text en Copyright: © 2018 Turkish Society of Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License |
spellingShingle | Original Investigation Cao, Hua Chen, Qiang Zhang, Gui-Can Chen, Liang-Wan Xu, Fan Zhang, Jia-Xin Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title | Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title_full | Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title_fullStr | Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title_full_unstemmed | Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title_short | Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
title_sort | clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6237790/ https://www.ncbi.nlm.nih.gov/pubmed/29952360 http://dx.doi.org/10.14744/AnatolJCardiol.2018.90001 |
work_keys_str_mv | AT caohua clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus AT chenqiang clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus AT zhangguican clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus AT chenliangwan clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus AT xufan clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus AT zhangjiaxin clinicalstudyofstandalonetransthoracicechocardiographyguidedpercutaneousocclusionofpatentductusarteriosus |