Cargando…

Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles

BACKGROUND: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept in...

Descripción completa

Detalles Bibliográficos
Autores principales: Snijders, T.E., Schlösser, T.P.C., van Gaalen, S.M., Castelein, R.M., Weinans, H., de Gast, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6242317/
https://www.ncbi.nlm.nih.gov/pubmed/30533596
http://dx.doi.org/10.2106/JBJS.OA.17.00063
_version_ 1783371816732983296
author Snijders, T.E.
Schlösser, T.P.C.
van Gaalen, S.M.
Castelein, R.M.
Weinans, H.
de Gast, A.
author_facet Snijders, T.E.
Schlösser, T.P.C.
van Gaalen, S.M.
Castelein, R.M.
Weinans, H.
de Gast, A.
author_sort Snijders, T.E.
collection PubMed
description BACKGROUND: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cup orientation. METHODS: Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC). RESULTS: Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version. CONCLUSIONS: The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation. CLINICAL RELEVANCE: By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis.
format Online
Article
Text
id pubmed-6242317
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-62423172018-12-07 Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles Snijders, T.E. Schlösser, T.P.C. van Gaalen, S.M. Castelein, R.M. Weinans, H. de Gast, A. JB JS Open Access Scientific Articles BACKGROUND: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cup orientation. METHODS: Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC). RESULTS: Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version. CONCLUSIONS: The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation. CLINICAL RELEVANCE: By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis. Wolters Kluwer 2018-07-12 /pmc/articles/PMC6242317/ /pubmed/30533596 http://dx.doi.org/10.2106/JBJS.OA.17.00063 Text en Copyright © 2018 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Scientific Articles
Snijders, T.E.
Schlösser, T.P.C.
van Gaalen, S.M.
Castelein, R.M.
Weinans, H.
de Gast, A.
Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title_full Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title_fullStr Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title_full_unstemmed Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title_short Trigonometric Algorithm Defining the True Three-Dimensional Acetabular Cup Orientation: Correlation Between Measured and Calculated Cup Orientation Angles
title_sort trigonometric algorithm defining the true three-dimensional acetabular cup orientation: correlation between measured and calculated cup orientation angles
topic Scientific Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6242317/
https://www.ncbi.nlm.nih.gov/pubmed/30533596
http://dx.doi.org/10.2106/JBJS.OA.17.00063
work_keys_str_mv AT snijderste trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles
AT schlossertpc trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles
AT vangaalensm trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles
AT casteleinrm trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles
AT weinansh trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles
AT degasta trigonometricalgorithmdefiningthetruethreedimensionalacetabularcuporientationcorrelationbetweenmeasuredandcalculatedcuporientationangles