Cargando…
A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study
BACKGROUND: Airborne microbe-carrying particles in the operating-room environment during total joint replacement are a risk factor for periprosthetic joint infection. The present study focuses on a simple environmental test, based on practices used in aseptic cleanrooms, to quantify the deposition o...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6242324/ https://www.ncbi.nlm.nih.gov/pubmed/30533587 http://dx.doi.org/10.2106/JBJS.OA.18.00001 |
_version_ | 1783371818457890816 |
---|---|
author | Harp, John H. |
author_facet | Harp, John H. |
author_sort | Harp, John H. |
collection | PubMed |
description | BACKGROUND: Airborne microbe-carrying particles in the operating-room environment during total joint replacement are a risk factor for periprosthetic joint infection. The present study focuses on a simple environmental test, based on practices used in aseptic cleanrooms, to quantify the deposition of microbe-carrying particles onto the sterile field. METHODS: Settle plates are exposed Petri dishes. A settle plate test system and sampling plan were developed from current practices used in aseptic manufacturing. A pilot study evaluated this system in an orthopaedic operating room during 22 total knee and hip arthroplasties. The microbial deposition total (MDT), expressed in colonies/m(2), is proposed as an outcome variable to report airborne sterile-field contamination as measured with settle plates. Two reference MDT levels were developed: (1) an upper limit of 450, corresponding with the ultraclean air definition of 10 colonies/m(3), and (2) a target level of 100, corresponding with 1 colony/m(3). These levels also correspond with widely used limits in aseptic cleanrooms and controlled environments. RESULTS: High MDT standard deviations were noted. Ninety-one percent (95% confidence interval, 71.0% to 98.7%) of wound zone MDT levels were within the upper limit. Twenty-seven percent (95% confidence interval, 12.9% to 48.4%) of wound zone levels were within the target level. CONCLUSIONS: Settle plates are a feasible technique to test environmental levels of microbe-carrying particles on sterile fields during total joint replacement for scientific and environmental quality studies. CLINICAL RELEVANCE: This settle plate operating-room environmental test can be used in future research to validate the presence of actual ultraclean-air conditions during periprosthetic joint infection outcome studies. Surgeons also can use this test to measure intraoperative airborne microbe-carrying-particle sterile-field contamination and compare it with ultraclean-air reference levels for environmental quality-control programs. |
format | Online Article Text |
id | pubmed-6242324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer |
record_format | MEDLINE/PubMed |
spelling | pubmed-62423242018-12-07 A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study Harp, John H. JB JS Open Access Scientific Articles BACKGROUND: Airborne microbe-carrying particles in the operating-room environment during total joint replacement are a risk factor for periprosthetic joint infection. The present study focuses on a simple environmental test, based on practices used in aseptic cleanrooms, to quantify the deposition of microbe-carrying particles onto the sterile field. METHODS: Settle plates are exposed Petri dishes. A settle plate test system and sampling plan were developed from current practices used in aseptic manufacturing. A pilot study evaluated this system in an orthopaedic operating room during 22 total knee and hip arthroplasties. The microbial deposition total (MDT), expressed in colonies/m(2), is proposed as an outcome variable to report airborne sterile-field contamination as measured with settle plates. Two reference MDT levels were developed: (1) an upper limit of 450, corresponding with the ultraclean air definition of 10 colonies/m(3), and (2) a target level of 100, corresponding with 1 colony/m(3). These levels also correspond with widely used limits in aseptic cleanrooms and controlled environments. RESULTS: High MDT standard deviations were noted. Ninety-one percent (95% confidence interval, 71.0% to 98.7%) of wound zone MDT levels were within the upper limit. Twenty-seven percent (95% confidence interval, 12.9% to 48.4%) of wound zone levels were within the target level. CONCLUSIONS: Settle plates are a feasible technique to test environmental levels of microbe-carrying particles on sterile fields during total joint replacement for scientific and environmental quality studies. CLINICAL RELEVANCE: This settle plate operating-room environmental test can be used in future research to validate the presence of actual ultraclean-air conditions during periprosthetic joint infection outcome studies. Surgeons also can use this test to measure intraoperative airborne microbe-carrying-particle sterile-field contamination and compare it with ultraclean-air reference levels for environmental quality-control programs. Wolters Kluwer 2018-08-24 /pmc/articles/PMC6242324/ /pubmed/30533587 http://dx.doi.org/10.2106/JBJS.OA.18.00001 Text en Copyright © 2018 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Scientific Articles Harp, John H. A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title | A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title_full | A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title_fullStr | A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title_full_unstemmed | A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title_short | A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study |
title_sort | clinical test to measure airborne microbial contamination on the sterile field during total joint replacement: method, reference values, and pilot study |
topic | Scientific Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6242324/ https://www.ncbi.nlm.nih.gov/pubmed/30533587 http://dx.doi.org/10.2106/JBJS.OA.18.00001 |
work_keys_str_mv | AT harpjohnh aclinicaltesttomeasureairbornemicrobialcontaminationonthesterilefieldduringtotaljointreplacementmethodreferencevaluesandpilotstudy AT harpjohnh clinicaltesttomeasureairbornemicrobialcontaminationonthesterilefieldduringtotaljointreplacementmethodreferencevaluesandpilotstudy |