Cargando…
Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images
PURPOSE: Positron emission tomography (PET) with Zirconium-89 (Zr-89)-labeled antibodies can be used for in vivo quantification of antibody uptake. Knowledge about measurement variability is required to ensure correct interpretation. However, no clinical studies have been reported on measurement var...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244539/ https://www.ncbi.nlm.nih.gov/pubmed/29713958 http://dx.doi.org/10.1007/s11307-018-1200-4 |
_version_ | 1783372074615570432 |
---|---|
author | Jauw, Yvonne W. S. Heijtel, Dennis F. Zijlstra, Josée M. Hoekstra, Otto S. de Vet, Henrica C. W. Vugts, Danielle J. Verheul, Henk M. Boellaard, Ronald Zweegman, Sonja van Dongen, Guus A. M. S. der Houven van Oordt, C. Willemien Menke-van Lammertsma, Adriaan A. Huisman, Marc C. |
author_facet | Jauw, Yvonne W. S. Heijtel, Dennis F. Zijlstra, Josée M. Hoekstra, Otto S. de Vet, Henrica C. W. Vugts, Danielle J. Verheul, Henk M. Boellaard, Ronald Zweegman, Sonja van Dongen, Guus A. M. S. der Houven van Oordt, C. Willemien Menke-van Lammertsma, Adriaan A. Huisman, Marc C. |
author_sort | Jauw, Yvonne W. S. |
collection | PubMed |
description | PURPOSE: Positron emission tomography (PET) with Zirconium-89 (Zr-89)-labeled antibodies can be used for in vivo quantification of antibody uptake. Knowledge about measurement variability is required to ensure correct interpretation. However, no clinical studies have been reported on measurement variability of Zr-89 immuno-PET. As variability due to low signal-to-noise is part of the total measurement variability, the aim of this study was to assess noise-induced variability of Zr-89 -immuno-PET using count-reduced clinical images. PROCEDURES: Data were acquired from three previously reported clinical studies with [(89)Zr]antiCD20 (74 MBq, n = 7), [(89)Zr]antiEGFR (37 MBq, n = 7), and [(89)Zr]antiCD44 (37 MBq, n = 13), with imaging obtained 1 to 6 days post injection (D0–D6). Volumes of interest (VOIs) were manually delineated for liver, spleen, kidney, lung, brain, and tumor. For blood pool and bone marrow, fixed-size VOIs were used. Original PET list mode data were split and reconstructed, resulting in two count-reduced images at 50 % of the original injected dose (e.g., 37 MBq(74inj)). Repeatability coefficients (RC) were obtained from Bland-Altman analysis on standardized uptake values (SUV) derived from VOIs applied to these images. RESULTS: The RC for the combined manually delineated organs for [(89)Zr] antiCD20 (37 MBq(74inj)) increased from D0 to D6 and was less than 6 % at all time points. Blood pool and bone marrow had higher RC, up to 43 % for 37 MBq(74inj) at D6. For tumor, the RC was up to 42 % for [(89)Zr]antiCD20 (37 MBq(74inj)). For [(89)Zr]antiCD20, (18 MBq(74inj)), [(89)Zr]antiEGFR (18 MBq(37inj)), and [(89)Zr]antiCD44 (18 MBq(37inj)), measurement variability was independent of the investigated antibody. CONCLUSIONS: Based on this study, noise-induced variability results in a RC for Zr-89-immuno-PET (37 MBq) around 6 % for manually delineated organs combined, increasing up to 43 % at D6 for blood pool and bone marrow, assuming similar biodistribution of antibodies. The signal-to-noise ratio leads to tumor RC up to 42 %. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11307-018-1200-4) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6244539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-62445392018-12-04 Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images Jauw, Yvonne W. S. Heijtel, Dennis F. Zijlstra, Josée M. Hoekstra, Otto S. de Vet, Henrica C. W. Vugts, Danielle J. Verheul, Henk M. Boellaard, Ronald Zweegman, Sonja van Dongen, Guus A. M. S. der Houven van Oordt, C. Willemien Menke-van Lammertsma, Adriaan A. Huisman, Marc C. Mol Imaging Biol Research Article PURPOSE: Positron emission tomography (PET) with Zirconium-89 (Zr-89)-labeled antibodies can be used for in vivo quantification of antibody uptake. Knowledge about measurement variability is required to ensure correct interpretation. However, no clinical studies have been reported on measurement variability of Zr-89 immuno-PET. As variability due to low signal-to-noise is part of the total measurement variability, the aim of this study was to assess noise-induced variability of Zr-89 -immuno-PET using count-reduced clinical images. PROCEDURES: Data were acquired from three previously reported clinical studies with [(89)Zr]antiCD20 (74 MBq, n = 7), [(89)Zr]antiEGFR (37 MBq, n = 7), and [(89)Zr]antiCD44 (37 MBq, n = 13), with imaging obtained 1 to 6 days post injection (D0–D6). Volumes of interest (VOIs) were manually delineated for liver, spleen, kidney, lung, brain, and tumor. For blood pool and bone marrow, fixed-size VOIs were used. Original PET list mode data were split and reconstructed, resulting in two count-reduced images at 50 % of the original injected dose (e.g., 37 MBq(74inj)). Repeatability coefficients (RC) were obtained from Bland-Altman analysis on standardized uptake values (SUV) derived from VOIs applied to these images. RESULTS: The RC for the combined manually delineated organs for [(89)Zr] antiCD20 (37 MBq(74inj)) increased from D0 to D6 and was less than 6 % at all time points. Blood pool and bone marrow had higher RC, up to 43 % for 37 MBq(74inj) at D6. For tumor, the RC was up to 42 % for [(89)Zr]antiCD20 (37 MBq(74inj)). For [(89)Zr]antiCD20, (18 MBq(74inj)), [(89)Zr]antiEGFR (18 MBq(37inj)), and [(89)Zr]antiCD44 (18 MBq(37inj)), measurement variability was independent of the investigated antibody. CONCLUSIONS: Based on this study, noise-induced variability results in a RC for Zr-89-immuno-PET (37 MBq) around 6 % for manually delineated organs combined, increasing up to 43 % at D6 for blood pool and bone marrow, assuming similar biodistribution of antibodies. The signal-to-noise ratio leads to tumor RC up to 42 %. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11307-018-1200-4) contains supplementary material, which is available to authorized users. Springer International Publishing 2018-04-30 2018 /pmc/articles/PMC6244539/ /pubmed/29713958 http://dx.doi.org/10.1007/s11307-018-1200-4 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Article Jauw, Yvonne W. S. Heijtel, Dennis F. Zijlstra, Josée M. Hoekstra, Otto S. de Vet, Henrica C. W. Vugts, Danielle J. Verheul, Henk M. Boellaard, Ronald Zweegman, Sonja van Dongen, Guus A. M. S. der Houven van Oordt, C. Willemien Menke-van Lammertsma, Adriaan A. Huisman, Marc C. Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title | Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title_full | Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title_fullStr | Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title_full_unstemmed | Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title_short | Noise-Induced Variability of Immuno-PET with Zirconium-89-Labeled Antibodies: an Analysis Based on Count-Reduced Clinical Images |
title_sort | noise-induced variability of immuno-pet with zirconium-89-labeled antibodies: an analysis based on count-reduced clinical images |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244539/ https://www.ncbi.nlm.nih.gov/pubmed/29713958 http://dx.doi.org/10.1007/s11307-018-1200-4 |
work_keys_str_mv | AT jauwyvonnews noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT heijteldennisf noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT zijlstrajoseem noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT hoekstraottos noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT devethenricacw noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT vugtsdaniellej noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT verheulhenkm noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT boellaardronald noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT zweegmansonja noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT vandongenguusams noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT derhouvenvanoordtcwillemienmenkevan noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT lammertsmaadriaana noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages AT huismanmarcc noiseinducedvariabilityofimmunopetwithzirconium89labeledantibodiesananalysisbasedoncountreducedclinicalimages |