Cargando…

Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform

The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ravindranath, Mepur H., Filippone, Edward J., Mahowald, Grace, Callender, Carly, Babu, Adarsh, Saidman, Susan, Ferrone, Soldano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244961/
https://www.ncbi.nlm.nih.gov/pubmed/30324227
http://dx.doi.org/10.1007/s12026-018-9027-2
_version_ 1783372147432882176
author Ravindranath, Mepur H.
Filippone, Edward J.
Mahowald, Grace
Callender, Carly
Babu, Adarsh
Saidman, Susan
Ferrone, Soldano
author_facet Ravindranath, Mepur H.
Filippone, Edward J.
Mahowald, Grace
Callender, Carly
Babu, Adarsh
Saidman, Susan
Ferrone, Soldano
author_sort Ravindranath, Mepur H.
collection PubMed
description The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates.
format Online
Article
Text
id pubmed-6244961
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-62449612018-12-04 Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform Ravindranath, Mepur H. Filippone, Edward J. Mahowald, Grace Callender, Carly Babu, Adarsh Saidman, Susan Ferrone, Soldano Immunol Res Original Article The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates. Springer US 2018-10-16 2018 /pmc/articles/PMC6244961/ /pubmed/30324227 http://dx.doi.org/10.1007/s12026-018-9027-2 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Ravindranath, Mepur H.
Filippone, Edward J.
Mahowald, Grace
Callender, Carly
Babu, Adarsh
Saidman, Susan
Ferrone, Soldano
Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title_full Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title_fullStr Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title_full_unstemmed Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title_short Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
title_sort significance of the intraindividual variability of hla igg antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a luminex platform
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244961/
https://www.ncbi.nlm.nih.gov/pubmed/30324227
http://dx.doi.org/10.1007/s12026-018-9027-2
work_keys_str_mv AT ravindranathmepurh significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT filipponeedwardj significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT mahowaldgrace significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT callendercarly significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT babuadarsh significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT saidmansusan significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform
AT ferronesoldano significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform