Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform
The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244961/ https://www.ncbi.nlm.nih.gov/pubmed/30324227 http://dx.doi.org/10.1007/s12026-018-9027-2 |
_version_ | 1783372147432882176 |
---|---|
author | Ravindranath, Mepur H. Filippone, Edward J. Mahowald, Grace Callender, Carly Babu, Adarsh Saidman, Susan Ferrone, Soldano |
author_facet | Ravindranath, Mepur H. Filippone, Edward J. Mahowald, Grace Callender, Carly Babu, Adarsh Saidman, Susan Ferrone, Soldano |
author_sort | Ravindranath, Mepur H. |
collection | PubMed |
description | The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates. |
format | Online Article Text |
id | pubmed-6244961 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-62449612018-12-04 Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform Ravindranath, Mepur H. Filippone, Edward J. Mahowald, Grace Callender, Carly Babu, Adarsh Saidman, Susan Ferrone, Soldano Immunol Res Original Article The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates. Springer US 2018-10-16 2018 /pmc/articles/PMC6244961/ /pubmed/30324227 http://dx.doi.org/10.1007/s12026-018-9027-2 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Ravindranath, Mepur H. Filippone, Edward J. Mahowald, Grace Callender, Carly Babu, Adarsh Saidman, Susan Ferrone, Soldano Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title | Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title_full | Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title_fullStr | Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title_full_unstemmed | Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title_short | Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform |
title_sort | significance of the intraindividual variability of hla igg antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a luminex platform |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244961/ https://www.ncbi.nlm.nih.gov/pubmed/30324227 http://dx.doi.org/10.1007/s12026-018-9027-2 |
work_keys_str_mv | AT ravindranathmepurh significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT filipponeedwardj significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT mahowaldgrace significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT callendercarly significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT babuadarsh significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT saidmansusan significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform AT ferronesoldano significanceoftheintraindividualvariabilityofhlaiggantibodiesinrenaldiseasepatientsobservedwithdifferentbeadsetsmonitoredwithtwodifferentsecondaryantibodiesonaluminexplatform |