Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol

Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED...

Descripción completa

Detalles Bibliográficos
Autores principales: Minderhoud, Savine C. S., van der Stelt, Femke, Molenschot, Mirella M. C., Koster, Michel S., Krings, Gregor J., Breur, Johannes M. P. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244991/
https://www.ncbi.nlm.nih.gov/pubmed/30076424
http://dx.doi.org/10.1007/s00246-018-1943-3
_version_ 1783372155180810240
author Minderhoud, Savine C. S.
van der Stelt, Femke
Molenschot, Mirella M. C.
Koster, Michel S.
Krings, Gregor J.
Breur, Johannes M. P. J.
author_facet Minderhoud, Savine C. S.
van der Stelt, Femke
Molenschot, Mirella M. C.
Koster, Michel S.
Krings, Gregor J.
Breur, Johannes M. P. J.
author_sort Minderhoud, Savine C. S.
collection PubMed
description Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3 years) underwent 100 3DRAs with a median ED of 0.54 mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6 mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64 mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00246-018-1943-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6244991
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-62449912018-12-04 Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol Minderhoud, Savine C. S. van der Stelt, Femke Molenschot, Mirella M. C. Koster, Michel S. Krings, Gregor J. Breur, Johannes M. P. J. Pediatr Cardiol Original Article Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3 years) underwent 100 3DRAs with a median ED of 0.54 mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6 mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64 mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00246-018-1943-3) contains supplementary material, which is available to authorized users. Springer US 2018-08-03 2018 /pmc/articles/PMC6244991/ /pubmed/30076424 http://dx.doi.org/10.1007/s00246-018-1943-3 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Minderhoud, Savine C. S.
van der Stelt, Femke
Molenschot, Mirella M. C.
Koster, Michel S.
Krings, Gregor J.
Breur, Johannes M. P. J.
Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title_full Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title_fullStr Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title_full_unstemmed Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title_short Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
title_sort dramatic dose reduction in three-dimensional rotational angiography after implementation of a simple dose reduction protocol
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244991/
https://www.ncbi.nlm.nih.gov/pubmed/30076424
http://dx.doi.org/10.1007/s00246-018-1943-3
work_keys_str_mv AT minderhoudsavinecs dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol
AT vandersteltfemke dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol
AT molenschotmirellamc dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol
AT kostermichels dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol
AT kringsgregorj dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol
AT breurjohannesmpj dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol