Cargando…
Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol
Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244991/ https://www.ncbi.nlm.nih.gov/pubmed/30076424 http://dx.doi.org/10.1007/s00246-018-1943-3 |
_version_ | 1783372155180810240 |
---|---|
author | Minderhoud, Savine C. S. van der Stelt, Femke Molenschot, Mirella M. C. Koster, Michel S. Krings, Gregor J. Breur, Johannes M. P. J. |
author_facet | Minderhoud, Savine C. S. van der Stelt, Femke Molenschot, Mirella M. C. Koster, Michel S. Krings, Gregor J. Breur, Johannes M. P. J. |
author_sort | Minderhoud, Savine C. S. |
collection | PubMed |
description | Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3 years) underwent 100 3DRAs with a median ED of 0.54 mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6 mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64 mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00246-018-1943-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6244991 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-62449912018-12-04 Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol Minderhoud, Savine C. S. van der Stelt, Femke Molenschot, Mirella M. C. Koster, Michel S. Krings, Gregor J. Breur, Johannes M. P. J. Pediatr Cardiol Original Article Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a readily available low dosage program, and a pre-3DRA run check. EDs were calculated with Monte Carlo PCXMC 2.0. Three observers blindly assessed 3DRA image quality of the dose reduction and normal-dose cohort. Between October 2014 and October 2015, 84 patients (median age 4.3 years) underwent 100 3DRAs with a median ED of 0.54 mSv (0.12–2.2) using the dose reduction protocol. Median ED in the normal-dose cohort (17 3DRAs) was 1.6 mSv (1.2–4.9). Image quality in the dose reduction cohort remained excellent. Correlations between ED and dose area product (DAP) and ED and skin dose were found with a ρ of 0.82 and 0.83, respectively. ED exposure of the entire catheterization was reduced to 2.64 mSv. Introduction of a simple protocol led to 66% dose reduction in 3DRA and 79% in the entire catheterization. 3DRA image quality in this group remained excellent. In 3DRA ED correlates well with DAP and skin dose, parameters readily available at the cathlab. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00246-018-1943-3) contains supplementary material, which is available to authorized users. Springer US 2018-08-03 2018 /pmc/articles/PMC6244991/ /pubmed/30076424 http://dx.doi.org/10.1007/s00246-018-1943-3 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Minderhoud, Savine C. S. van der Stelt, Femke Molenschot, Mirella M. C. Koster, Michel S. Krings, Gregor J. Breur, Johannes M. P. J. Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title | Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title_full | Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title_fullStr | Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title_full_unstemmed | Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title_short | Dramatic Dose Reduction in Three-Dimensional Rotational Angiography After Implementation of a Simple Dose Reduction Protocol |
title_sort | dramatic dose reduction in three-dimensional rotational angiography after implementation of a simple dose reduction protocol |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6244991/ https://www.ncbi.nlm.nih.gov/pubmed/30076424 http://dx.doi.org/10.1007/s00246-018-1943-3 |
work_keys_str_mv | AT minderhoudsavinecs dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol AT vandersteltfemke dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol AT molenschotmirellamc dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol AT kostermichels dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol AT kringsgregorj dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol AT breurjohannesmpj dramaticdosereductioninthreedimensionalrotationalangiographyafterimplementationofasimpledosereductionprotocol |