Cargando…
Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study
Direct laryngoscopy using a Macintosh laryngoscope is the most widely used approach; however, this skill is not easy for novices and trainees. We evaluated the performance of novices using a laryngoscope with a three-dimensional (3D)-printed ergonomic grip on an airway manikin. Forty second-year med...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6245686/ https://www.ncbi.nlm.nih.gov/pubmed/30458013 http://dx.doi.org/10.1371/journal.pone.0207445 |
_version_ | 1783372284833038336 |
---|---|
author | Kim, Sung-Hoon Kwon, Jeonghoon Kim, Youn-Jung Lee, Hyung-Joo Seo, Hyo-Chang Lim, Seung Bok Joo, Segyeong Seo, Dong-Woo Kim, Won-Young Hong, Sang-Bum |
author_facet | Kim, Sung-Hoon Kwon, Jeonghoon Kim, Youn-Jung Lee, Hyung-Joo Seo, Hyo-Chang Lim, Seung Bok Joo, Segyeong Seo, Dong-Woo Kim, Won-Young Hong, Sang-Bum |
author_sort | Kim, Sung-Hoon |
collection | PubMed |
description | Direct laryngoscopy using a Macintosh laryngoscope is the most widely used approach; however, this skill is not easy for novices and trainees. We evaluated the performance of novices using a laryngoscope with a three-dimensional (3D)-printed ergonomic grip on an airway manikin. Forty second-year medical students were enrolled. Endotracheal intubation was attempted using a conventional Macintosh laryngoscope with or without a 3D-printed ergonomic support grip. Primary outcomes were intubation time and overall success rate. Secondary outcomes were number of unsuccessful attempts, first-attempt success rate, airway Cormack-Lehane (CL) grade, and difficulty score. In the easy airway scenario, intubation time, and the overall success rate were similar between two group. CL grade and ease-of-use scores were significantly better for those using the ergonomic support grip (P < 0.05). In the difficult airway scenario, intubation time (49.7±37.5 vs. 35.5±29.2, P = 0.013), the first-attempt success rate (67.5% vs. 90%, P = 0.029), number of attempts (1.4±0.6 vs. 1.1±0.4, P = 0.006), CL grade (2 [2, 2] vs. 2 [1, 1], P = 0.012), and ease-of-use scores (3.5 [2, 4] vs. 4 [3, 5], P = 0.008) were significantly better for those using the ergonomic support grip. Linear mixed model analysis showed that the ergonomic support grip had a favorable effect on CL grade (P<0.001), ease-of-use scores (P<0.001), intubation time (P = 0.015), and number of intubation attempts (P = 0.029). Our custom 3D-printed ergonomic laryngoscope support grip improved several indicators related to the successful endotracheal intubation in the easy and difficult scenario simulated on an airway manikin. This grip may be useful for intubation training and practice. |
format | Online Article Text |
id | pubmed-6245686 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-62456862018-12-01 Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study Kim, Sung-Hoon Kwon, Jeonghoon Kim, Youn-Jung Lee, Hyung-Joo Seo, Hyo-Chang Lim, Seung Bok Joo, Segyeong Seo, Dong-Woo Kim, Won-Young Hong, Sang-Bum PLoS One Research Article Direct laryngoscopy using a Macintosh laryngoscope is the most widely used approach; however, this skill is not easy for novices and trainees. We evaluated the performance of novices using a laryngoscope with a three-dimensional (3D)-printed ergonomic grip on an airway manikin. Forty second-year medical students were enrolled. Endotracheal intubation was attempted using a conventional Macintosh laryngoscope with or without a 3D-printed ergonomic support grip. Primary outcomes were intubation time and overall success rate. Secondary outcomes were number of unsuccessful attempts, first-attempt success rate, airway Cormack-Lehane (CL) grade, and difficulty score. In the easy airway scenario, intubation time, and the overall success rate were similar between two group. CL grade and ease-of-use scores were significantly better for those using the ergonomic support grip (P < 0.05). In the difficult airway scenario, intubation time (49.7±37.5 vs. 35.5±29.2, P = 0.013), the first-attempt success rate (67.5% vs. 90%, P = 0.029), number of attempts (1.4±0.6 vs. 1.1±0.4, P = 0.006), CL grade (2 [2, 2] vs. 2 [1, 1], P = 0.012), and ease-of-use scores (3.5 [2, 4] vs. 4 [3, 5], P = 0.008) were significantly better for those using the ergonomic support grip. Linear mixed model analysis showed that the ergonomic support grip had a favorable effect on CL grade (P<0.001), ease-of-use scores (P<0.001), intubation time (P = 0.015), and number of intubation attempts (P = 0.029). Our custom 3D-printed ergonomic laryngoscope support grip improved several indicators related to the successful endotracheal intubation in the easy and difficult scenario simulated on an airway manikin. This grip may be useful for intubation training and practice. Public Library of Science 2018-11-20 /pmc/articles/PMC6245686/ /pubmed/30458013 http://dx.doi.org/10.1371/journal.pone.0207445 Text en © 2018 Kim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kim, Sung-Hoon Kwon, Jeonghoon Kim, Youn-Jung Lee, Hyung-Joo Seo, Hyo-Chang Lim, Seung Bok Joo, Segyeong Seo, Dong-Woo Kim, Won-Young Hong, Sang-Bum Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title | Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title_full | Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title_fullStr | Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title_full_unstemmed | Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title_short | Impact of a custom-made 3D printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—A manikin study |
title_sort | impact of a custom-made 3d printed ergonomic grip for direct laryngoscopy on novice intubation performance in a simulated easy and difficult airway scenario—a manikin study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6245686/ https://www.ncbi.nlm.nih.gov/pubmed/30458013 http://dx.doi.org/10.1371/journal.pone.0207445 |
work_keys_str_mv | AT kimsunghoon impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT kwonjeonghoon impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT kimyounjung impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT leehyungjoo impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT seohyochang impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT limseungbok impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT joosegyeong impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT seodongwoo impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT kimwonyoung impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy AT hongsangbum impactofacustommade3dprintedergonomicgripfordirectlaryngoscopyonnoviceintubationperformanceinasimulatedeasyanddifficultairwayscenarioamanikinstudy |