A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane

[Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavali...

Descripción completa

Detalles Bibliográficos
Autores principales: Locke, Andrea K., Means, Anna Kristen, Dong, Ping, Nichols, Tyler J., Coté, Gerard L., Grunlan, Melissa A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6247246/
https://www.ncbi.nlm.nih.gov/pubmed/30474080
http://dx.doi.org/10.1021/acsabm.8b00267
_version_ 1783372459403116544
author Locke, Andrea K.
Means, Anna Kristen
Dong, Ping
Nichols, Tyler J.
Coté, Gerard L.
Grunlan, Melissa A.
author_facet Locke, Andrea K.
Means, Anna Kristen
Dong, Ping
Nichols, Tyler J.
Coté, Gerard L.
Grunlan, Melissa A.
author_sort Locke, Andrea K.
collection PubMed
description [Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). In the present work, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting eventual subcutaneous implantation and optical probing through the skin. A “self-cleaning” hydrogel was utilized because of its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and therefore extend the sensor lifetime. Thus, we prepared a hollow, cylindrical hydrogel based on a thermoresponsive electrostatic double network design composed of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid. Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane. It consisted of 5, 10, 15, 30, or 40 alternating bilayers of positively charged poly(diallyldimethylammonium chloride) and negatively charged poly(sodium 4-styrenesulfonate). With 30 bilayers, the leaching of the smaller-sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference of ∼11%.
format Online
Article
Text
id pubmed-6247246
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-62472462018-11-23 A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane Locke, Andrea K. Means, Anna Kristen Dong, Ping Nichols, Tyler J. Coté, Gerard L. Grunlan, Melissa A. ACS Appl Bio Mater [Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). In the present work, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting eventual subcutaneous implantation and optical probing through the skin. A “self-cleaning” hydrogel was utilized because of its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and therefore extend the sensor lifetime. Thus, we prepared a hollow, cylindrical hydrogel based on a thermoresponsive electrostatic double network design composed of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid. Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane. It consisted of 5, 10, 15, 30, or 40 alternating bilayers of positively charged poly(diallyldimethylammonium chloride) and negatively charged poly(sodium 4-styrenesulfonate). With 30 bilayers, the leaching of the smaller-sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference of ∼11%. American Chemical Society 2018-10-10 2018-11-19 /pmc/articles/PMC6247246/ /pubmed/30474080 http://dx.doi.org/10.1021/acsabm.8b00267 Text en Copyright © 2018 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Locke, Andrea K.
Means, Anna Kristen
Dong, Ping
Nichols, Tyler J.
Coté, Gerard L.
Grunlan, Melissa A.
A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title_full A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title_fullStr A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title_full_unstemmed A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title_short A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
title_sort layer-by-layer approach to retain a fluorescent glucose sensing assay within the cavity of a hydrogel membrane
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6247246/
https://www.ncbi.nlm.nih.gov/pubmed/30474080
http://dx.doi.org/10.1021/acsabm.8b00267
work_keys_str_mv AT lockeandreak alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT meansannakristen alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT dongping alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT nicholstylerj alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT cotegerardl alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT grunlanmelissaa alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT lockeandreak layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT meansannakristen layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT dongping layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT nicholstylerj layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT cotegerardl layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane
AT grunlanmelissaa layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane