Cargando…
A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
[Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavali...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2018
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6247246/ https://www.ncbi.nlm.nih.gov/pubmed/30474080 http://dx.doi.org/10.1021/acsabm.8b00267 |
_version_ | 1783372459403116544 |
---|---|
author | Locke, Andrea K. Means, Anna Kristen Dong, Ping Nichols, Tyler J. Coté, Gerard L. Grunlan, Melissa A. |
author_facet | Locke, Andrea K. Means, Anna Kristen Dong, Ping Nichols, Tyler J. Coté, Gerard L. Grunlan, Melissa A. |
author_sort | Locke, Andrea K. |
collection | PubMed |
description | [Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). In the present work, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting eventual subcutaneous implantation and optical probing through the skin. A “self-cleaning” hydrogel was utilized because of its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and therefore extend the sensor lifetime. Thus, we prepared a hollow, cylindrical hydrogel based on a thermoresponsive electrostatic double network design composed of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid. Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane. It consisted of 5, 10, 15, 30, or 40 alternating bilayers of positively charged poly(diallyldimethylammonium chloride) and negatively charged poly(sodium 4-styrenesulfonate). With 30 bilayers, the leaching of the smaller-sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference of ∼11%. |
format | Online Article Text |
id | pubmed-6247246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-62472462018-11-23 A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane Locke, Andrea K. Means, Anna Kristen Dong, Ping Nichols, Tyler J. Coté, Gerard L. Grunlan, Melissa A. ACS Appl Bio Mater [Image: see text] A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). In the present work, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting eventual subcutaneous implantation and optical probing through the skin. A “self-cleaning” hydrogel was utilized because of its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and therefore extend the sensor lifetime. Thus, we prepared a hollow, cylindrical hydrogel based on a thermoresponsive electrostatic double network design composed of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid. Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane. It consisted of 5, 10, 15, 30, or 40 alternating bilayers of positively charged poly(diallyldimethylammonium chloride) and negatively charged poly(sodium 4-styrenesulfonate). With 30 bilayers, the leaching of the smaller-sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference of ∼11%. American Chemical Society 2018-10-10 2018-11-19 /pmc/articles/PMC6247246/ /pubmed/30474080 http://dx.doi.org/10.1021/acsabm.8b00267 Text en Copyright © 2018 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes. |
spellingShingle | Locke, Andrea K. Means, Anna Kristen Dong, Ping Nichols, Tyler J. Coté, Gerard L. Grunlan, Melissa A. A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title | A Layer-by-Layer Approach To Retain a Fluorescent
Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title_full | A Layer-by-Layer Approach To Retain a Fluorescent
Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title_fullStr | A Layer-by-Layer Approach To Retain a Fluorescent
Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title_full_unstemmed | A Layer-by-Layer Approach To Retain a Fluorescent
Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title_short | A Layer-by-Layer Approach To Retain a Fluorescent
Glucose Sensing Assay within the Cavity of a Hydrogel Membrane |
title_sort | layer-by-layer approach to retain a fluorescent
glucose sensing assay within the cavity of a hydrogel membrane |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6247246/ https://www.ncbi.nlm.nih.gov/pubmed/30474080 http://dx.doi.org/10.1021/acsabm.8b00267 |
work_keys_str_mv | AT lockeandreak alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT meansannakristen alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT dongping alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT nicholstylerj alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT cotegerardl alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT grunlanmelissaa alayerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT lockeandreak layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT meansannakristen layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT dongping layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT nicholstylerj layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT cotegerardl layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane AT grunlanmelissaa layerbylayerapproachtoretainafluorescentglucosesensingassaywithinthecavityofahydrogelmembrane |