Cargando…

Two consecutive limb lengthenings with the same PRECICE nail: a technical note

PURPOSE: The most significant advance in our time about limb lengthening is the magnetic lengthening nail, as the first reports appeared to show good results with accurate lengthening rates and good regenerate bone formation. The described complication rate is generally low. They avoid external fixa...

Descripción completa

Detalles Bibliográficos
Autores principales: Couto, André, Freitas, Joana, Alegrete, Nuno, Coutinho, Jorge, Costa, Gilberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249150/
https://www.ncbi.nlm.nih.gov/pubmed/30232655
http://dx.doi.org/10.1007/s11751-018-0317-y
_version_ 1783372682395385856
author Couto, André
Freitas, Joana
Alegrete, Nuno
Coutinho, Jorge
Costa, Gilberto
author_facet Couto, André
Freitas, Joana
Alegrete, Nuno
Coutinho, Jorge
Costa, Gilberto
author_sort Couto, André
collection PubMed
description PURPOSE: The most significant advance in our time about limb lengthening is the magnetic lengthening nail, as the first reports appeared to show good results with accurate lengthening rates and good regenerate bone formation. The described complication rate is generally low. They avoid external fixation elements, and are activated transcutaneously, so the patient’s pain and discomfort are reduced and the rehabilitation is faster and more effective. The aim of authors is to describe a special technical issue of the PRECICE system: the nail can be extended inside the patient limb (after the osteotomy), but it also can be retracted inside the limb after achieving the bone union. METHODS: The authors present a case in which the limb lengthening has been performed in consecutive lengthening periods using the same nail. The nail was extended and retracted by altering the settings on the external remote control as well as accurately setting the rate of distraction. RESULTS: After two consecutive femoral lengthening with the same PRECICE nail, the patient no longer has a significant lower limb length discrepancy and patient satisfaction was high. During this clinical case, we were not confronted with any type of complications. CONCLUSION: This technique utilizes the principles and advantages of lengthening over an magnetic lengthening nail, avoids the necessity of nail removal and minimizes the complication rates and the overall time for complete recovery. LEVEL OF EVIDENCE: Level IV.
format Online
Article
Text
id pubmed-6249150
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-62491502018-12-06 Two consecutive limb lengthenings with the same PRECICE nail: a technical note Couto, André Freitas, Joana Alegrete, Nuno Coutinho, Jorge Costa, Gilberto Strategies Trauma Limb Reconstr Technical Report PURPOSE: The most significant advance in our time about limb lengthening is the magnetic lengthening nail, as the first reports appeared to show good results with accurate lengthening rates and good regenerate bone formation. The described complication rate is generally low. They avoid external fixation elements, and are activated transcutaneously, so the patient’s pain and discomfort are reduced and the rehabilitation is faster and more effective. The aim of authors is to describe a special technical issue of the PRECICE system: the nail can be extended inside the patient limb (after the osteotomy), but it also can be retracted inside the limb after achieving the bone union. METHODS: The authors present a case in which the limb lengthening has been performed in consecutive lengthening periods using the same nail. The nail was extended and retracted by altering the settings on the external remote control as well as accurately setting the rate of distraction. RESULTS: After two consecutive femoral lengthening with the same PRECICE nail, the patient no longer has a significant lower limb length discrepancy and patient satisfaction was high. During this clinical case, we were not confronted with any type of complications. CONCLUSION: This technique utilizes the principles and advantages of lengthening over an magnetic lengthening nail, avoids the necessity of nail removal and minimizes the complication rates and the overall time for complete recovery. LEVEL OF EVIDENCE: Level IV. Springer Milan 2018-09-19 2018-11 /pmc/articles/PMC6249150/ /pubmed/30232655 http://dx.doi.org/10.1007/s11751-018-0317-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Technical Report
Couto, André
Freitas, Joana
Alegrete, Nuno
Coutinho, Jorge
Costa, Gilberto
Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title_full Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title_fullStr Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title_full_unstemmed Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title_short Two consecutive limb lengthenings with the same PRECICE nail: a technical note
title_sort two consecutive limb lengthenings with the same precice nail: a technical note
topic Technical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249150/
https://www.ncbi.nlm.nih.gov/pubmed/30232655
http://dx.doi.org/10.1007/s11751-018-0317-y
work_keys_str_mv AT coutoandre twoconsecutivelimblengtheningswiththesameprecicenailatechnicalnote
AT freitasjoana twoconsecutivelimblengtheningswiththesameprecicenailatechnicalnote
AT alegretenuno twoconsecutivelimblengtheningswiththesameprecicenailatechnicalnote
AT coutinhojorge twoconsecutivelimblengtheningswiththesameprecicenailatechnicalnote
AT costagilberto twoconsecutivelimblengtheningswiththesameprecicenailatechnicalnote