Cargando…

High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation

The plasma membrane is the site of intercellular communication and subsequent intracellular signal transduction. The specific visualization of the plasma membrane in living cells, however, is difficult using fluorescence-based techniques owing to the high background signals from intracellular organe...

Descripción completa

Detalles Bibliográficos
Autores principales: Mizuguchi, Takaha, Yasui, Masato, Nuriya, Mutsuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249386/
https://www.ncbi.nlm.nih.gov/pubmed/30466062
http://dx.doi.org/10.1016/j.isci.2018.11.008
_version_ 1783372737576697856
author Mizuguchi, Takaha
Yasui, Masato
Nuriya, Mutsuo
author_facet Mizuguchi, Takaha
Yasui, Masato
Nuriya, Mutsuo
author_sort Mizuguchi, Takaha
collection PubMed
description The plasma membrane is the site of intercellular communication and subsequent intracellular signal transduction. The specific visualization of the plasma membrane in living cells, however, is difficult using fluorescence-based techniques owing to the high background signals from intracellular organelles. In this study, we show that second harmonic generation (SHG) is a high-resolution plasma membrane-selective imaging technique that enables multifaceted investigations of the plasma membrane. In contrast to fluorescence imaging, SHG specifically visualizes the plasma membrane at locations that are not attached to artificial substrates and allows high-resolution imaging because of its subresolution nature. These properties were exploited to measure the distances from the plasma membrane to subcortical actin and tubulin fibers, revealing the precise cytoskeletal organization beneath the plasma membrane. Thus, SHG imaging enables the specific visualization of phenomena at the plasma membrane with unprecedented precision and versatility and should facilitate cell biology research focused on the plasma membrane.
format Online
Article
Text
id pubmed-6249386
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-62493862018-11-30 High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation Mizuguchi, Takaha Yasui, Masato Nuriya, Mutsuo iScience Article The plasma membrane is the site of intercellular communication and subsequent intracellular signal transduction. The specific visualization of the plasma membrane in living cells, however, is difficult using fluorescence-based techniques owing to the high background signals from intracellular organelles. In this study, we show that second harmonic generation (SHG) is a high-resolution plasma membrane-selective imaging technique that enables multifaceted investigations of the plasma membrane. In contrast to fluorescence imaging, SHG specifically visualizes the plasma membrane at locations that are not attached to artificial substrates and allows high-resolution imaging because of its subresolution nature. These properties were exploited to measure the distances from the plasma membrane to subcortical actin and tubulin fibers, revealing the precise cytoskeletal organization beneath the plasma membrane. Thus, SHG imaging enables the specific visualization of phenomena at the plasma membrane with unprecedented precision and versatility and should facilitate cell biology research focused on the plasma membrane. Elsevier 2018-11-05 /pmc/articles/PMC6249386/ /pubmed/30466062 http://dx.doi.org/10.1016/j.isci.2018.11.008 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Mizuguchi, Takaha
Yasui, Masato
Nuriya, Mutsuo
High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title_full High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title_fullStr High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title_full_unstemmed High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title_short High-Resolution Plasma Membrane-Selective Imaging by Second Harmonic Generation
title_sort high-resolution plasma membrane-selective imaging by second harmonic generation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6249386/
https://www.ncbi.nlm.nih.gov/pubmed/30466062
http://dx.doi.org/10.1016/j.isci.2018.11.008
work_keys_str_mv AT mizuguchitakaha highresolutionplasmamembraneselectiveimagingbysecondharmonicgeneration
AT yasuimasato highresolutionplasmamembraneselectiveimagingbysecondharmonicgeneration
AT nuriyamutsuo highresolutionplasmamembraneselectiveimagingbysecondharmonicgeneration