Cargando…

Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases

Mono-isocentric volumetric-modulated arc therapy (VMAT) can be used to treat multiple brain metastases. It remains unknown whether mono-isocentric VMAT can improve the dose distribution compared with dual-isocentric dynamic conformal arc therapy (DCAT), especially for two brain metastases. We compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Uto, Megumi, Mizowaki, Takashi, Ogura, Kengo, Mukumoto, Nobutaka, Katagiri, Tomohiro, Takehana, Keiichi, Hiraoka, Masahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6251429/
https://www.ncbi.nlm.nih.gov/pubmed/30102325
http://dx.doi.org/10.1093/jrr/rry064
_version_ 1783373120298549248
author Uto, Megumi
Mizowaki, Takashi
Ogura, Kengo
Mukumoto, Nobutaka
Katagiri, Tomohiro
Takehana, Keiichi
Hiraoka, Masahiro
author_facet Uto, Megumi
Mizowaki, Takashi
Ogura, Kengo
Mukumoto, Nobutaka
Katagiri, Tomohiro
Takehana, Keiichi
Hiraoka, Masahiro
author_sort Uto, Megumi
collection PubMed
description Mono-isocentric volumetric-modulated arc therapy (VMAT) can be used to treat multiple brain metastases. It remains unknown whether mono-isocentric VMAT can improve the dose distribution compared with dual-isocentric dynamic conformal arc therapy (DCAT), especially for two brain metastases. We compared the dose distribution between dual-isocentric DCAT and mono-isocentric VMAT for two large brain metastases, and analyzed the relationship between the distance between the two targets and the difference in dose distribution. A total of 19 patients, each with two large brain metastases, were enrolled. The dose prescribed for each planning target volume (PTV) was 28 Gy in five fractions (D(99.8) = 100%). We created new indices derived from conformity indices suggested by the Radiation Therapy Oncology Group (RTOG; mRTOG-CI) and Paddick et al. (mIP-CI), using the dosimetric parameters of the sum of the two PTVs. The median PTV was 5.05 cm(3) (range, 2.10–28.47). VMAT significantly improved mRTOG-CI and mIP-CI compared with DCAT. In all cases, VMAT was able to improve mRTOG-CI and mIP-CI compared with DCAT. Whereas the normal brain volume receiving 5 Gy was similar between the two modalities, the normal brain receiving 10, 12, 15, 20, 25 and 28 Gy (V(10)–V(28)) was significantly smaller in VMAT. The mean beam-on times were 213.3 s and 121.9 s in DCAT and VMAT, respectively (P < 0.001). Mono-isocentric VMAT improved the target conformity and reduced the beam-on time and V(10)–V(28) of the normal brain for not only two close metastases but also two distant metastases. Mono-isocentric VMAT seems to be a promising treatment technique for two large brain metastases.
format Online
Article
Text
id pubmed-6251429
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-62514292018-11-28 Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases Uto, Megumi Mizowaki, Takashi Ogura, Kengo Mukumoto, Nobutaka Katagiri, Tomohiro Takehana, Keiichi Hiraoka, Masahiro J Radiat Res Regular Paper Mono-isocentric volumetric-modulated arc therapy (VMAT) can be used to treat multiple brain metastases. It remains unknown whether mono-isocentric VMAT can improve the dose distribution compared with dual-isocentric dynamic conformal arc therapy (DCAT), especially for two brain metastases. We compared the dose distribution between dual-isocentric DCAT and mono-isocentric VMAT for two large brain metastases, and analyzed the relationship between the distance between the two targets and the difference in dose distribution. A total of 19 patients, each with two large brain metastases, were enrolled. The dose prescribed for each planning target volume (PTV) was 28 Gy in five fractions (D(99.8) = 100%). We created new indices derived from conformity indices suggested by the Radiation Therapy Oncology Group (RTOG; mRTOG-CI) and Paddick et al. (mIP-CI), using the dosimetric parameters of the sum of the two PTVs. The median PTV was 5.05 cm(3) (range, 2.10–28.47). VMAT significantly improved mRTOG-CI and mIP-CI compared with DCAT. In all cases, VMAT was able to improve mRTOG-CI and mIP-CI compared with DCAT. Whereas the normal brain volume receiving 5 Gy was similar between the two modalities, the normal brain receiving 10, 12, 15, 20, 25 and 28 Gy (V(10)–V(28)) was significantly smaller in VMAT. The mean beam-on times were 213.3 s and 121.9 s in DCAT and VMAT, respectively (P < 0.001). Mono-isocentric VMAT improved the target conformity and reduced the beam-on time and V(10)–V(28) of the normal brain for not only two close metastases but also two distant metastases. Mono-isocentric VMAT seems to be a promising treatment technique for two large brain metastases. Oxford University Press 2018-11 2018-08-09 /pmc/articles/PMC6251429/ /pubmed/30102325 http://dx.doi.org/10.1093/jrr/rry064 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Regular Paper
Uto, Megumi
Mizowaki, Takashi
Ogura, Kengo
Mukumoto, Nobutaka
Katagiri, Tomohiro
Takehana, Keiichi
Hiraoka, Masahiro
Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title_full Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title_fullStr Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title_full_unstemmed Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title_short Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
title_sort dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
topic Regular Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6251429/
https://www.ncbi.nlm.nih.gov/pubmed/30102325
http://dx.doi.org/10.1093/jrr/rry064
work_keys_str_mv AT utomegumi dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT mizowakitakashi dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT ogurakengo dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT mukumotonobutaka dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT katagiritomohiro dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT takehanakeiichi dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases
AT hiraokamasahiro dosimetriccomparisonbetweendualisocentricdynamicconformalarctherapyandmonoisocentricvolumetricmodulatedarctherapyfortwolargebrainmetastases