Cargando…

1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)

BACKGROUND: The National Healthcare Safety Network (NHSN), developed and used by the Centers for Disease Control and Prevention (CDC) for surveillance of healthcare-associated infections (HAIs), provides benchmark measures, such as standardized infection ratio (SIRs), that CDC and its partners in he...

Descripción completa

Detalles Bibliográficos
Autores principales: Sapiano, Mathew R P, Edwards, Jonathan R, Pollock, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6252659/
http://dx.doi.org/10.1093/ofid/ofy209.147
_version_ 1783373314374238208
author Sapiano, Mathew R P
Edwards, Jonathan R
Pollock, Daniel
author_facet Sapiano, Mathew R P
Edwards, Jonathan R
Pollock, Daniel
author_sort Sapiano, Mathew R P
collection PubMed
description BACKGROUND: The National Healthcare Safety Network (NHSN), developed and used by the Centers for Disease Control and Prevention (CDC) for surveillance of healthcare-associated infections (HAIs), provides benchmark measures, such as standardized infection ratio (SIRs), that CDC and its partners in healthcare and public health use for prevention purposes. NHSN provides benchmarks for each HAI measure separately, but a composite HAI measure could provide a more rounded assessment of HAI problems and prevention opportunities. METHODS: Several issues must be addressed to produce a sound HAI composite measure, the most of which is that the SIR can be inaccurate for facilities with low HAI exposure (e.g., low device days, operative procedure volume). We remedy this issue with the Adjusted Ranking Metric (ARM), a new measure that reliability-adjusts the SIR using a Bayesian mixed effects model. The ARM is particularly useful in the production of a composite measure because ARMs are well-suited to comparison between facilities. The composite was therefore produced by applying adjustments to the ARMs to account for (1) differences between exposure to separate HAI types within facilities and (2) differences in frequency and severity between HAIs. The composite is calculated for 6 HAIs based on 2015 data. RESULTS: Case studies of 3 facilities (table) show that the new composite measure provides a meaningful measure of overall facility performance that is less prone to the biases that afflict simple combinations of SIRs. CONCLUSION: We introduce a framework for calculating a composite HAI measure that is flexible, customizable, and transparent. The current implementation of the framework is intended to assist in prevention efforts and can be easily modified to include cost weights, if desired. Flexibility in weighting the HAIs provides an opportunity for different stakeholders to customize the composite measure to their own needs. DISCLOSURES: All authors: No reported disclosures.
format Online
Article
Text
id pubmed-6252659
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-62526592018-11-28 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN) Sapiano, Mathew R P Edwards, Jonathan R Pollock, Daniel Open Forum Infect Dis Abstracts BACKGROUND: The National Healthcare Safety Network (NHSN), developed and used by the Centers for Disease Control and Prevention (CDC) for surveillance of healthcare-associated infections (HAIs), provides benchmark measures, such as standardized infection ratio (SIRs), that CDC and its partners in healthcare and public health use for prevention purposes. NHSN provides benchmarks for each HAI measure separately, but a composite HAI measure could provide a more rounded assessment of HAI problems and prevention opportunities. METHODS: Several issues must be addressed to produce a sound HAI composite measure, the most of which is that the SIR can be inaccurate for facilities with low HAI exposure (e.g., low device days, operative procedure volume). We remedy this issue with the Adjusted Ranking Metric (ARM), a new measure that reliability-adjusts the SIR using a Bayesian mixed effects model. The ARM is particularly useful in the production of a composite measure because ARMs are well-suited to comparison between facilities. The composite was therefore produced by applying adjustments to the ARMs to account for (1) differences between exposure to separate HAI types within facilities and (2) differences in frequency and severity between HAIs. The composite is calculated for 6 HAIs based on 2015 data. RESULTS: Case studies of 3 facilities (table) show that the new composite measure provides a meaningful measure of overall facility performance that is less prone to the biases that afflict simple combinations of SIRs. CONCLUSION: We introduce a framework for calculating a composite HAI measure that is flexible, customizable, and transparent. The current implementation of the framework is intended to assist in prevention efforts and can be easily modified to include cost weights, if desired. Flexibility in weighting the HAIs provides an opportunity for different stakeholders to customize the composite measure to their own needs. DISCLOSURES: All authors: No reported disclosures. Oxford University Press 2018-11-26 /pmc/articles/PMC6252659/ http://dx.doi.org/10.1093/ofid/ofy209.147 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of Infectious Diseases Society of America. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Abstracts
Sapiano, Mathew R P
Edwards, Jonathan R
Pollock, Daniel
1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title_full 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title_fullStr 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title_full_unstemmed 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title_short 1762. The Adjusted Ranking Metric (ARM) and Its Use in Composite Measures for HAI Prevention in the National Healthcare Safety Network (NHSN)
title_sort 1762. the adjusted ranking metric (arm) and its use in composite measures for hai prevention in the national healthcare safety network (nhsn)
topic Abstracts
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6252659/
http://dx.doi.org/10.1093/ofid/ofy209.147
work_keys_str_mv AT sapianomathewrp 1762theadjustedrankingmetricarmanditsuseincompositemeasuresforhaipreventioninthenationalhealthcaresafetynetworknhsn
AT edwardsjonathanr 1762theadjustedrankingmetricarmanditsuseincompositemeasuresforhaipreventioninthenationalhealthcaresafetynetworknhsn
AT pollockdaniel 1762theadjustedrankingmetricarmanditsuseincompositemeasuresforhaipreventioninthenationalhealthcaresafetynetworknhsn