Cargando…

Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction

BACKGROUND: Tripling semitendinosus tendon for ACL graft preparation facilitates creation of longer and thicker grafts. Our objective was to evaluate the mechanical difference between tripled tendon grafts, prepared by three methods, by comparing with quadrupled tendon graft. METHODS: Bovine hind-fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Geethan, I., Santhosh Sahanand, K., Ashwin Vijay, P. R., Rajan, David V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6258592/
https://www.ncbi.nlm.nih.gov/pubmed/30483889
http://dx.doi.org/10.1186/s40634-018-0163-3
_version_ 1783374527586107392
author Geethan, I.
Santhosh Sahanand, K.
Ashwin Vijay, P. R.
Rajan, David V.
author_facet Geethan, I.
Santhosh Sahanand, K.
Ashwin Vijay, P. R.
Rajan, David V.
author_sort Geethan, I.
collection PubMed
description BACKGROUND: Tripling semitendinosus tendon for ACL graft preparation facilitates creation of longer and thicker grafts. Our objective was to evaluate the mechanical difference between tripled tendon grafts, prepared by three methods, by comparing with quadrupled tendon graft. METHODS: Bovine hind-foot hoof extensors were allocated to four groups. Group I had quadrupled graft construct. Tripled graft constructs were prepared by passing the tendon to the Endobutton CL loop and stitching the third strand to (i) the loop (in Group II) or (ii) to one strand(in Group III) or (iii)to loop and both tendon strands (in Group IV). The constructs were preloaded from 10 to 50 N at 0.1 Hz for 10 cycles, followed by 1000 cycles of sinusoidal loading between 50 and 250 N at a frequency of 0.5 Hz. The specimens were then subjected to load to failure test at the rate of 50 mm/min. Displacement with cyclic loading, load at failure and the mode of failure were noted. RESULTS: The load at failure was 957 ± 23.30 N (Mean ± Standard Deviation) in Group I, 590.8 ± 24.40 N in Group II, 682.6 ± 59.28 N in Group III and 963.4 ± 21.72 N in Group IV. The displacement with cyclic loading was 1.13 ± 0.11 mm in Group I, 4.908 ± 0.55 mm in Group II, 1.822 ± 0.55 mm in Group III and 1. 126 ± .018 mm in Group IV. There was no significant difference between the Groups I and IV with respect to the load at failure and displacement (p > 0.05). The values were significantly different in Group II and Group III (p < 0.01), when compared to groups I and IV. CONCLUSIONS: Tripled grafts have mechanical properties equivalent to quadrupled grafts only when the three strands are sutured together. Caution may be warranted when using suspensory fixation device with tripled tendons and the third strand must be securely attached to the loop of fixation device and to the other two strands.
format Online
Article
Text
id pubmed-6258592
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-62585922018-12-11 Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction Geethan, I. Santhosh Sahanand, K. Ashwin Vijay, P. R. Rajan, David V. J Exp Orthop Research BACKGROUND: Tripling semitendinosus tendon for ACL graft preparation facilitates creation of longer and thicker grafts. Our objective was to evaluate the mechanical difference between tripled tendon grafts, prepared by three methods, by comparing with quadrupled tendon graft. METHODS: Bovine hind-foot hoof extensors were allocated to four groups. Group I had quadrupled graft construct. Tripled graft constructs were prepared by passing the tendon to the Endobutton CL loop and stitching the third strand to (i) the loop (in Group II) or (ii) to one strand(in Group III) or (iii)to loop and both tendon strands (in Group IV). The constructs were preloaded from 10 to 50 N at 0.1 Hz for 10 cycles, followed by 1000 cycles of sinusoidal loading between 50 and 250 N at a frequency of 0.5 Hz. The specimens were then subjected to load to failure test at the rate of 50 mm/min. Displacement with cyclic loading, load at failure and the mode of failure were noted. RESULTS: The load at failure was 957 ± 23.30 N (Mean ± Standard Deviation) in Group I, 590.8 ± 24.40 N in Group II, 682.6 ± 59.28 N in Group III and 963.4 ± 21.72 N in Group IV. The displacement with cyclic loading was 1.13 ± 0.11 mm in Group I, 4.908 ± 0.55 mm in Group II, 1.822 ± 0.55 mm in Group III and 1. 126 ± .018 mm in Group IV. There was no significant difference between the Groups I and IV with respect to the load at failure and displacement (p > 0.05). The values were significantly different in Group II and Group III (p < 0.01), when compared to groups I and IV. CONCLUSIONS: Tripled grafts have mechanical properties equivalent to quadrupled grafts only when the three strands are sutured together. Caution may be warranted when using suspensory fixation device with tripled tendons and the third strand must be securely attached to the loop of fixation device and to the other two strands. Springer Berlin Heidelberg 2018-11-27 /pmc/articles/PMC6258592/ /pubmed/30483889 http://dx.doi.org/10.1186/s40634-018-0163-3 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Geethan, I.
Santhosh Sahanand, K.
Ashwin Vijay, P. R.
Rajan, David V.
Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title_full Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title_fullStr Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title_full_unstemmed Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title_short Mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
title_sort mechanical assessment of tripled hamstring tendon graft when using suspensory fixation for cruciate ligament reconstruction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6258592/
https://www.ncbi.nlm.nih.gov/pubmed/30483889
http://dx.doi.org/10.1186/s40634-018-0163-3
work_keys_str_mv AT geethani mechanicalassessmentoftripledhamstringtendongraftwhenusingsuspensoryfixationforcruciateligamentreconstruction
AT santhoshsahanandk mechanicalassessmentoftripledhamstringtendongraftwhenusingsuspensoryfixationforcruciateligamentreconstruction
AT ashwinvijaypr mechanicalassessmentoftripledhamstringtendongraftwhenusingsuspensoryfixationforcruciateligamentreconstruction
AT rajandavidv mechanicalassessmentoftripledhamstringtendongraftwhenusingsuspensoryfixationforcruciateligamentreconstruction