Cargando…

Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease

BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the...

Descripción completa

Detalles Bibliográficos
Autores principales: Henningsson, Markus, Zahr, Riad Abou, Dyer, Adrian, Greil, Gerald F., Burkhardt, Barbara, Tandon, Animesh, Hussain, Tarique
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6260764/
https://www.ncbi.nlm.nih.gov/pubmed/30474554
http://dx.doi.org/10.1186/s12968-018-0508-1
_version_ 1783374866949341184
author Henningsson, Markus
Zahr, Riad Abou
Dyer, Adrian
Greil, Gerald F.
Burkhardt, Barbara
Tandon, Animesh
Hussain, Tarique
author_facet Henningsson, Markus
Zahr, Riad Abou
Dyer, Adrian
Greil, Gerald F.
Burkhardt, Barbara
Tandon, Animesh
Hussain, Tarique
author_sort Henningsson, Markus
collection PubMed
description BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNR(l)) and local contrast-to-noise ratio (CNR(l)). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNR(l) for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNR(l) was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-018-0508-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6260764
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-62607642018-12-10 Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease Henningsson, Markus Zahr, Riad Abou Dyer, Adrian Greil, Gerald F. Burkhardt, Barbara Tandon, Animesh Hussain, Tarique J Cardiovasc Magn Reson Research BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNR(l)) and local contrast-to-noise ratio (CNR(l)). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNR(l) for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNR(l) was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-018-0508-1) contains supplementary material, which is available to authorized users. BioMed Central 2018-11-26 /pmc/articles/PMC6260764/ /pubmed/30474554 http://dx.doi.org/10.1186/s12968-018-0508-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Henningsson, Markus
Zahr, Riad Abou
Dyer, Adrian
Greil, Gerald F.
Burkhardt, Barbara
Tandon, Animesh
Hussain, Tarique
Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title_full Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title_fullStr Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title_full_unstemmed Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title_short Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
title_sort feasibility of 3d black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6260764/
https://www.ncbi.nlm.nih.gov/pubmed/30474554
http://dx.doi.org/10.1186/s12968-018-0508-1
work_keys_str_mv AT henningssonmarkus feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT zahrriadabou feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT dyeradrian feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT greilgeraldf feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT burkhardtbarbara feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT tandonanimesh feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease
AT hussaintarique feasibilityof3dblackbloodvariablerefocusinganglefastspinechocardiovascularmagneticresonanceforvisualizationofthewholeheartandgreatvesselsincongenitalheartdisease