Cargando…

A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine

A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-oper...

Descripción completa

Detalles Bibliográficos
Autores principales: Chao, Paul C.-P., Chiang, Pei-Yu, Kao, Yung-Hua, Tu, Tse-Yi, Yang, Chih-Yu, Tarng, Der-Cherng, Wey, Chin-Long
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263509/
https://www.ncbi.nlm.nih.gov/pubmed/30423988
http://dx.doi.org/10.3390/s18113854
_version_ 1783375309632962560
author Chao, Paul C.-P.
Chiang, Pei-Yu
Kao, Yung-Hua
Tu, Tse-Yi
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
author_facet Chao, Paul C.-P.
Chiang, Pei-Yu
Kao, Yung-Hua
Tu, Tse-Yi
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
author_sort Chao, Paul C.-P.
collection PubMed
description A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert’s law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%.
format Online
Article
Text
id pubmed-6263509
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62635092018-12-12 A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine Chao, Paul C.-P. Chiang, Pei-Yu Kao, Yung-Hua Tu, Tse-Yi Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long Sensors (Basel) Article A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert’s law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%. MDPI 2018-11-09 /pmc/articles/PMC6263509/ /pubmed/30423988 http://dx.doi.org/10.3390/s18113854 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chao, Paul C.-P.
Chiang, Pei-Yu
Kao, Yung-Hua
Tu, Tse-Yi
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title_full A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title_fullStr A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title_full_unstemmed A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title_short A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
title_sort portable, wireless photoplethysomography sensor for assessing health of arteriovenous fistula using class-weighted support vector machine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263509/
https://www.ncbi.nlm.nih.gov/pubmed/30423988
http://dx.doi.org/10.3390/s18113854
work_keys_str_mv AT chaopaulcp aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT chiangpeiyu aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT kaoyunghua aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT tutseyi aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT yangchihyu aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT tarngdercherng aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT weychinlong aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT chaopaulcp portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT chiangpeiyu portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT kaoyunghua portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT tutseyi portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT yangchihyu portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT tarngdercherng portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine
AT weychinlong portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine