A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine
A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-oper...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263509/ https://www.ncbi.nlm.nih.gov/pubmed/30423988 http://dx.doi.org/10.3390/s18113854 |
_version_ | 1783375309632962560 |
---|---|
author | Chao, Paul C.-P. Chiang, Pei-Yu Kao, Yung-Hua Tu, Tse-Yi Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long |
author_facet | Chao, Paul C.-P. Chiang, Pei-Yu Kao, Yung-Hua Tu, Tse-Yi Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long |
author_sort | Chao, Paul C.-P. |
collection | PubMed |
description | A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert’s law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%. |
format | Online Article Text |
id | pubmed-6263509 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62635092018-12-12 A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine Chao, Paul C.-P. Chiang, Pei-Yu Kao, Yung-Hua Tu, Tse-Yi Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long Sensors (Basel) Article A portable, wireless photoplethysomography (PPG) sensor for assessing arteriovenous fistula (AVF) by using class-weighted support vector machines (SVM) was presented in this study. Nowadays, in hospital, AVF are assessed by ultrasound Doppler machines, which are bulky, expensive, complicated-to-operate, and time-consuming. In this study, new PPG sensors were proposed and developed successfully to provide portable and inexpensive solutions for AVF assessments. To develop the sensor, at first, by combining the dimensionless number analysis and the optical Beer Lambert’s law, five input features were derived for the SVM classifier. In the next step, to increase the signal-noise ratio (SNR) of PPG signals, the front-end readout circuitries were designed to fully use the dynamic range of analog-digital converter (ADC) by controlling the circuitries gain and the light intensity of light emitted diode (LED). Digital signal processing algorithms were proposed next to check and fix signal anomalies. Finally, the class-weighted SVM classifiers employed five different kernel functions to assess AVF quality. The assessment results were provided to doctors for diagonosis and detemining ensuing proper treatments. The experimental results showed that the proposed PPG sensors successfully achieved an accuracy of 89.11% in assessing health of AVF and with a type II error of only 9.59%. MDPI 2018-11-09 /pmc/articles/PMC6263509/ /pubmed/30423988 http://dx.doi.org/10.3390/s18113854 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chao, Paul C.-P. Chiang, Pei-Yu Kao, Yung-Hua Tu, Tse-Yi Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title | A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title_full | A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title_fullStr | A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title_full_unstemmed | A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title_short | A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine |
title_sort | portable, wireless photoplethysomography sensor for assessing health of arteriovenous fistula using class-weighted support vector machine |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263509/ https://www.ncbi.nlm.nih.gov/pubmed/30423988 http://dx.doi.org/10.3390/s18113854 |
work_keys_str_mv | AT chaopaulcp aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT chiangpeiyu aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT kaoyunghua aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT tutseyi aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT yangchihyu aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT tarngdercherng aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT weychinlong aportablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT chaopaulcp portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT chiangpeiyu portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT kaoyunghua portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT tutseyi portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT yangchihyu portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT tarngdercherng portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine AT weychinlong portablewirelessphotoplethysomographysensorforassessinghealthofarteriovenousfistulausingclassweightedsupportvectormachine |