Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation
An ordinary optical fiber ultra-high temperature sensor based on infrared radiation with the advantages of simple structure and compact is presented. The sensing system consists of a detection fiber and a common transmission fiber. The detector fiber is formed by annealing a piece of ordinary fiber...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263532/ https://www.ncbi.nlm.nih.gov/pubmed/30469408 http://dx.doi.org/10.3390/s18114071 |
_version_ | 1783375315107577856 |
---|---|
author | Lin, Qijing Zhao, Na Yao, Kun Jiang, Zhuangde Tian, Bian Shi, Peng Chen, Feng |
author_facet | Lin, Qijing Zhao, Na Yao, Kun Jiang, Zhuangde Tian, Bian Shi, Peng Chen, Feng |
author_sort | Lin, Qijing |
collection | PubMed |
description | An ordinary optical fiber ultra-high temperature sensor based on infrared radiation with the advantages of simple structure and compact is presented. The sensing system consists of a detection fiber and a common transmission fiber. The detector fiber is formed by annealing a piece of ordinary fiber at high temperature twice, which changes the properties of the fiber and breaks the temperature limit of ordinary fiber. The transmission fiber is a bending insensitive optical fiber. A static calibration system was set up to determine the performance of the sensor and three heating experiments were carried out. The temperature response sensitivities were 0.010 dBm/K, 0.009 dBm/K and 0.010 dBm/K, respectively, which indicate that the sensor has good repeatability. The sensor can withstand a high temperature of 1823 K for 58 h with an error of less than 1%. The main reason why the developed ordinary optical fiber sensor can work steadily for a long time at high temperature is the formation of β-cristobalite, which is stable at high-temperature. |
format | Online Article Text |
id | pubmed-6263532 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62635322018-12-12 Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation Lin, Qijing Zhao, Na Yao, Kun Jiang, Zhuangde Tian, Bian Shi, Peng Chen, Feng Sensors (Basel) Article An ordinary optical fiber ultra-high temperature sensor based on infrared radiation with the advantages of simple structure and compact is presented. The sensing system consists of a detection fiber and a common transmission fiber. The detector fiber is formed by annealing a piece of ordinary fiber at high temperature twice, which changes the properties of the fiber and breaks the temperature limit of ordinary fiber. The transmission fiber is a bending insensitive optical fiber. A static calibration system was set up to determine the performance of the sensor and three heating experiments were carried out. The temperature response sensitivities were 0.010 dBm/K, 0.009 dBm/K and 0.010 dBm/K, respectively, which indicate that the sensor has good repeatability. The sensor can withstand a high temperature of 1823 K for 58 h with an error of less than 1%. The main reason why the developed ordinary optical fiber sensor can work steadily for a long time at high temperature is the formation of β-cristobalite, which is stable at high-temperature. MDPI 2018-11-21 /pmc/articles/PMC6263532/ /pubmed/30469408 http://dx.doi.org/10.3390/s18114071 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lin, Qijing Zhao, Na Yao, Kun Jiang, Zhuangde Tian, Bian Shi, Peng Chen, Feng Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title | Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title_full | Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title_fullStr | Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title_full_unstemmed | Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title_short | Ordinary Optical Fiber Sensor for Ultra-High Temperature Measurement Based on Infrared Radiation |
title_sort | ordinary optical fiber sensor for ultra-high temperature measurement based on infrared radiation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263532/ https://www.ncbi.nlm.nih.gov/pubmed/30469408 http://dx.doi.org/10.3390/s18114071 |
work_keys_str_mv | AT linqijing ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT zhaona ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT yaokun ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT jiangzhuangde ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT tianbian ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT shipeng ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation AT chenfeng ordinaryopticalfibersensorforultrahightemperaturemeasurementbasedoninfraredradiation |