Cargando…

Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †

Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Jia, Ji, Xu, Chengtian, Pan, Shijia, Xia, Stephen, Wei, Peter, Noh, Hae Young, Zhang, Pei, Jiang, Xiaofan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263898/
https://www.ncbi.nlm.nih.gov/pubmed/30400608
http://dx.doi.org/10.3390/s18113775
_version_ 1783375374006091776
author Jia, Ji
Xu, Chengtian
Pan, Shijia
Xia, Stephen
Wei, Peter
Noh, Hae Young
Zhang, Pei
Jiang, Xiaofan
author_facet Jia, Ji
Xu, Chengtian
Pan, Shijia
Xia, Stephen
Wei, Peter
Noh, Hae Young
Zhang, Pei
Jiang, Xiaofan
author_sort Jia, Ji
collection PubMed
description Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly care. Prior work on perspiration (sweat) sensing required the user either to be static or to wear the adhesive sensor directly on the skin, which limits users’ mobility and comfort. In this paper, we present a novel conductive thread-based textile sensor that measures an individual’s on-cloth sweat quantity. The sensor consists of three conductive threads. Each conductive thread is surrounded by a braided cotton cover. An additional braided cotton cover is placed outside the three conductive threads, holding them in a position that is stable for measurement. the sensor can be embedded at various locations on a person’s clothing. When the person sweats, the cotton braids absorb the sweat and change the conductivity (resistance) between conductive threads. We used a voltage dividing circuit to measure this resistance as the sensor output (DC). We then conducted a sensor calibration to map this measured voltage to the quantity of electrolyte solution (with the same density as sweat) applied to the sensor. We used this sensor to measure individuals’ perspiration quantity and infer their perceived perspiration levels. The system is able to limit the average prediction error to 0.4 levels when compared to five pre-defined perceived perspiration levels.
format Online
Article
Text
id pubmed-6263898
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62638982018-12-12 Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † Jia, Ji Xu, Chengtian Pan, Shijia Xia, Stephen Wei, Peter Noh, Hae Young Zhang, Pei Jiang, Xiaofan Sensors (Basel) Article Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly care. Prior work on perspiration (sweat) sensing required the user either to be static or to wear the adhesive sensor directly on the skin, which limits users’ mobility and comfort. In this paper, we present a novel conductive thread-based textile sensor that measures an individual’s on-cloth sweat quantity. The sensor consists of three conductive threads. Each conductive thread is surrounded by a braided cotton cover. An additional braided cotton cover is placed outside the three conductive threads, holding them in a position that is stable for measurement. the sensor can be embedded at various locations on a person’s clothing. When the person sweats, the cotton braids absorb the sweat and change the conductivity (resistance) between conductive threads. We used a voltage dividing circuit to measure this resistance as the sensor output (DC). We then conducted a sensor calibration to map this measured voltage to the quantity of electrolyte solution (with the same density as sweat) applied to the sensor. We used this sensor to measure individuals’ perspiration quantity and infer their perceived perspiration levels. The system is able to limit the average prediction error to 0.4 levels when compared to five pre-defined perceived perspiration levels. MDPI 2018-11-05 /pmc/articles/PMC6263898/ /pubmed/30400608 http://dx.doi.org/10.3390/s18113775 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jia, Ji
Xu, Chengtian
Pan, Shijia
Xia, Stephen
Wei, Peter
Noh, Hae Young
Zhang, Pei
Jiang, Xiaofan
Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title_full Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title_fullStr Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title_full_unstemmed Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title_short Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
title_sort conductive thread-based textile sensor for continuous perspiration level monitoring †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263898/
https://www.ncbi.nlm.nih.gov/pubmed/30400608
http://dx.doi.org/10.3390/s18113775
work_keys_str_mv AT jiaji conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT xuchengtian conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT panshijia conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT xiastephen conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT weipeter conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT nohhaeyoung conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT zhangpei conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring
AT jiangxiaofan conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring