Cargando…
Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring †
Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly ca...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263898/ https://www.ncbi.nlm.nih.gov/pubmed/30400608 http://dx.doi.org/10.3390/s18113775 |
_version_ | 1783375374006091776 |
---|---|
author | Jia, Ji Xu, Chengtian Pan, Shijia Xia, Stephen Wei, Peter Noh, Hae Young Zhang, Pei Jiang, Xiaofan |
author_facet | Jia, Ji Xu, Chengtian Pan, Shijia Xia, Stephen Wei, Peter Noh, Hae Young Zhang, Pei Jiang, Xiaofan |
author_sort | Jia, Ji |
collection | PubMed |
description | Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly care. Prior work on perspiration (sweat) sensing required the user either to be static or to wear the adhesive sensor directly on the skin, which limits users’ mobility and comfort. In this paper, we present a novel conductive thread-based textile sensor that measures an individual’s on-cloth sweat quantity. The sensor consists of three conductive threads. Each conductive thread is surrounded by a braided cotton cover. An additional braided cotton cover is placed outside the three conductive threads, holding them in a position that is stable for measurement. the sensor can be embedded at various locations on a person’s clothing. When the person sweats, the cotton braids absorb the sweat and change the conductivity (resistance) between conductive threads. We used a voltage dividing circuit to measure this resistance as the sensor output (DC). We then conducted a sensor calibration to map this measured voltage to the quantity of electrolyte solution (with the same density as sweat) applied to the sensor. We used this sensor to measure individuals’ perspiration quantity and infer their perceived perspiration levels. The system is able to limit the average prediction error to 0.4 levels when compared to five pre-defined perceived perspiration levels. |
format | Online Article Text |
id | pubmed-6263898 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62638982018-12-12 Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † Jia, Ji Xu, Chengtian Pan, Shijia Xia, Stephen Wei, Peter Noh, Hae Young Zhang, Pei Jiang, Xiaofan Sensors (Basel) Article Individual perspiration level indicates a person’s physical status as well as their comfort level. Therefore, continuous perspiration level measurement enables people to monitor these conditions for applications including fitness assessment, athlete physical status monitoring, and patient/elderly care. Prior work on perspiration (sweat) sensing required the user either to be static or to wear the adhesive sensor directly on the skin, which limits users’ mobility and comfort. In this paper, we present a novel conductive thread-based textile sensor that measures an individual’s on-cloth sweat quantity. The sensor consists of three conductive threads. Each conductive thread is surrounded by a braided cotton cover. An additional braided cotton cover is placed outside the three conductive threads, holding them in a position that is stable for measurement. the sensor can be embedded at various locations on a person’s clothing. When the person sweats, the cotton braids absorb the sweat and change the conductivity (resistance) between conductive threads. We used a voltage dividing circuit to measure this resistance as the sensor output (DC). We then conducted a sensor calibration to map this measured voltage to the quantity of electrolyte solution (with the same density as sweat) applied to the sensor. We used this sensor to measure individuals’ perspiration quantity and infer their perceived perspiration levels. The system is able to limit the average prediction error to 0.4 levels when compared to five pre-defined perceived perspiration levels. MDPI 2018-11-05 /pmc/articles/PMC6263898/ /pubmed/30400608 http://dx.doi.org/10.3390/s18113775 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jia, Ji Xu, Chengtian Pan, Shijia Xia, Stephen Wei, Peter Noh, Hae Young Zhang, Pei Jiang, Xiaofan Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title | Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title_full | Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title_fullStr | Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title_full_unstemmed | Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title_short | Conductive Thread-Based Textile Sensor for Continuous Perspiration Level Monitoring † |
title_sort | conductive thread-based textile sensor for continuous perspiration level monitoring † |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263898/ https://www.ncbi.nlm.nih.gov/pubmed/30400608 http://dx.doi.org/10.3390/s18113775 |
work_keys_str_mv | AT jiaji conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT xuchengtian conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT panshijia conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT xiastephen conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT weipeter conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT nohhaeyoung conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT zhangpei conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring AT jiangxiaofan conductivethreadbasedtextilesensorforcontinuousperspirationlevelmonitoring |