Cargando…

Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination

In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was vali...

Descripción completa

Detalles Bibliográficos
Autores principales: Finšgar, Matjaž, Majer, David, Maver, Uroš, Maver, Tina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263962/
https://www.ncbi.nlm.nih.gov/pubmed/30445794
http://dx.doi.org/10.3390/s18113976
_version_ 1783375386516652032
author Finšgar, Matjaž
Majer, David
Maver, Uroš
Maver, Tina
author_facet Finšgar, Matjaž
Majer, David
Maver, Uroš
Maver, Tina
author_sort Finšgar, Matjaž
collection PubMed
description In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was validated for an accumulation potential of –1.1 V vs. Ag/AgCl and an accumulation time of 60 s. A comparative analysis of bare SPE and SbFSPE showed that the detection and quantification limits decrease for the bare SPE. The method with the bare SPE showed a linear response in the 69.8–368.4 µg/L concentration range, whereas linearity for the SbFSPE was in the 24.0–319.1 µg/L concentration range. This work also reports the reason why the multiple standard addition method instead of a linear calibration curve for Pb(II) analysis should be employed. Furthermore, the analytical method employing SbFSPE was found to be more accurate and precise compared to the use of bare SPE when sensors were employed for the first time, however this performance changed significantly when these sensors were reused in the same manner. Furthermore, electrochemical impedance spectroscopy was used for the first time to analyse the electrochemical response of sensors after being used for multiple successive analyses. Surface characterisation before and after multiple successive uses of bare SPE and SbFSPE sensors, with atomic force microscopy and field emission scanning electron microscopy, showed sensor degradation. The interference effect of Cd(II), Zn(II), As(III), Fe(II), Na(I), K(I), Ca(II), Mg(II), NO(3)(–), Bi(III), Cu(II), Sn(II), and Hg(II) on the Pb(II) stripping signal was also studied. Finally, the application of SbFSPE was tested on a real water sample (from a local river), which showed high precision (RSD = 8.1%, n = 5) and accurate results.
format Online
Article
Text
id pubmed-6263962
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-62639622018-12-12 Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination Finšgar, Matjaž Majer, David Maver, Uroš Maver, Tina Sensors (Basel) Article In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was validated for an accumulation potential of –1.1 V vs. Ag/AgCl and an accumulation time of 60 s. A comparative analysis of bare SPE and SbFSPE showed that the detection and quantification limits decrease for the bare SPE. The method with the bare SPE showed a linear response in the 69.8–368.4 µg/L concentration range, whereas linearity for the SbFSPE was in the 24.0–319.1 µg/L concentration range. This work also reports the reason why the multiple standard addition method instead of a linear calibration curve for Pb(II) analysis should be employed. Furthermore, the analytical method employing SbFSPE was found to be more accurate and precise compared to the use of bare SPE when sensors were employed for the first time, however this performance changed significantly when these sensors were reused in the same manner. Furthermore, electrochemical impedance spectroscopy was used for the first time to analyse the electrochemical response of sensors after being used for multiple successive analyses. Surface characterisation before and after multiple successive uses of bare SPE and SbFSPE sensors, with atomic force microscopy and field emission scanning electron microscopy, showed sensor degradation. The interference effect of Cd(II), Zn(II), As(III), Fe(II), Na(I), K(I), Ca(II), Mg(II), NO(3)(–), Bi(III), Cu(II), Sn(II), and Hg(II) on the Pb(II) stripping signal was also studied. Finally, the application of SbFSPE was tested on a real water sample (from a local river), which showed high precision (RSD = 8.1%, n = 5) and accurate results. MDPI 2018-11-15 /pmc/articles/PMC6263962/ /pubmed/30445794 http://dx.doi.org/10.3390/s18113976 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Finšgar, Matjaž
Majer, David
Maver, Uroš
Maver, Tina
Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_full Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_fullStr Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_full_unstemmed Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_short Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_sort reusability of spe and sb-modified spe sensors for trace pb(ii) determination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263962/
https://www.ncbi.nlm.nih.gov/pubmed/30445794
http://dx.doi.org/10.3390/s18113976
work_keys_str_mv AT finsgarmatjaz reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT majerdavid reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT maveruros reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT mavertina reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination