Cargando…
Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance
Static load tests of foundation piles are the basic method for the designing or verification of adopted design solutions which concern the foundation of a building structure. Preparation of a typical test station using the so-called inverted beam method is very expensive and labor-intensive. The set...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263973/ https://www.ncbi.nlm.nih.gov/pubmed/30469396 http://dx.doi.org/10.3390/s18114067 |
_version_ | 1783375389076226048 |
---|---|
author | Muszyński, Zbigniew Rybak, Jarosław Kaczor, Paulina |
author_facet | Muszyński, Zbigniew Rybak, Jarosław Kaczor, Paulina |
author_sort | Muszyński, Zbigniew |
collection | PubMed |
description | Static load tests of foundation piles are the basic method for the designing or verification of adopted design solutions which concern the foundation of a building structure. Preparation of a typical test station using the so-called inverted beam method is very expensive and labor-intensive. The settlement values of the loaded pile are usually recorded using accurate dial gauges. These gauges are attached to a reference beam located in close proximity to the pile under test, which may cause systematic errors (difficult to detect) caused by the displacement of the adopted reference beam. The application of geodetic methods makes it possible to maintain an independent, external reference system, and to verify the readouts from dial gauges. The article presents an innovative instrumentation for a self-balanced stand for the static load test made from a closed-end, double steel pipe. Instead of typical, precise geometric leveling, the semi-automatic measuring techniques were used: motorized total station measurement and terrestrial laser scanning controlled by a computer. The processing of the acquired data made it possible to determine the vertical displacements of both parts of the examined pile and compare displacements with the results from the dial gauges. On the basis of the excess of the collected observations, it was possible to assess the accuracy, which confirmed the usefulness of measuring techniques under study. |
format | Online Article Text |
id | pubmed-6263973 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-62639732018-12-12 Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance Muszyński, Zbigniew Rybak, Jarosław Kaczor, Paulina Sensors (Basel) Article Static load tests of foundation piles are the basic method for the designing or verification of adopted design solutions which concern the foundation of a building structure. Preparation of a typical test station using the so-called inverted beam method is very expensive and labor-intensive. The settlement values of the loaded pile are usually recorded using accurate dial gauges. These gauges are attached to a reference beam located in close proximity to the pile under test, which may cause systematic errors (difficult to detect) caused by the displacement of the adopted reference beam. The application of geodetic methods makes it possible to maintain an independent, external reference system, and to verify the readouts from dial gauges. The article presents an innovative instrumentation for a self-balanced stand for the static load test made from a closed-end, double steel pipe. Instead of typical, precise geometric leveling, the semi-automatic measuring techniques were used: motorized total station measurement and terrestrial laser scanning controlled by a computer. The processing of the acquired data made it possible to determine the vertical displacements of both parts of the examined pile and compare displacements with the results from the dial gauges. On the basis of the excess of the collected observations, it was possible to assess the accuracy, which confirmed the usefulness of measuring techniques under study. MDPI 2018-11-21 /pmc/articles/PMC6263973/ /pubmed/30469396 http://dx.doi.org/10.3390/s18114067 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Muszyński, Zbigniew Rybak, Jarosław Kaczor, Paulina Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title | Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title_full | Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title_fullStr | Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title_full_unstemmed | Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title_short | Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance |
title_sort | accuracy assessment of semi-automatic measuring techniques applied to displacement control in self-balanced pile capacity testing appliance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6263973/ https://www.ncbi.nlm.nih.gov/pubmed/30469396 http://dx.doi.org/10.3390/s18114067 |
work_keys_str_mv | AT muszynskizbigniew accuracyassessmentofsemiautomaticmeasuringtechniquesappliedtodisplacementcontrolinselfbalancedpilecapacitytestingappliance AT rybakjarosław accuracyassessmentofsemiautomaticmeasuringtechniquesappliedtodisplacementcontrolinselfbalancedpilecapacitytestingappliance AT kaczorpaulina accuracyassessmentofsemiautomaticmeasuringtechniquesappliedtodisplacementcontrolinselfbalancedpilecapacitytestingappliance |